Application of the generalized contrast-to-noise ratio to assess photoacoustic image quality

被引:64
|
作者
Kempski, Kelley M. [1 ]
Graham, Michelle T. [2 ]
Gubbi, Mardava R. [2 ]
Palmer, Theron [1 ]
Bell, Muyinatu A. Lediju [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
基金
美国国家科学基金会;
关键词
LAG SPATIAL COHERENCE;
D O I
10.1364/BOE.391026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The generalized contrast-to-noise ratio (gCNR) is a relatively new image quality metric designed to assess the probability of lesion detectability in ultrasound images. Although gCNR was initially demonstrated with ultrasound images, the metric is theoretically applicable to multiple types of medical images. In this paper, the applicability of gCNR to photoacoustic images is investigated. The gCNR was computed for both simulated and experimental photoacoustic images generated by amplitude-based (i.e., delay-and-sum) and coherence-based (i.e., short-lag spatial coherence) beamformers. These gCNR measurements were compared to three more traditional image quality metrics (i.e., contrast, contrast-to-noise ratio, and signal-to-noise ratio) applied to the same datasets. An increase in qualitative target visibility generally corresponded with increased gCNR. In addition, gCNR magnitude was more directly related to the separability of photoacoustic signals from their background, which degraded with the presence of limited bandwidth artifacts and increased levels of channel noise. At high gCNR values (i.e., 0.95-1), contrast, contrast-to-noise ratio, and signal-to-noise ratio varied by up to 23.7-56.2 dB, 2.0-3.4, and 26.5-7.6x10(20), respectively, for simulated, experimental phantom, and in vivo data. Therefore, these traditional metrics can experience large variations when a target is fully detectable, and additional increases in these values would have no impact on photoacoustic target detectability. In addition, gCNR is robust to changes in traditional metrics introduced by applying a minimum threshold to image amplitudes. In tandem with other photoacoustic image quality metrics and with a defined range of 0 to 1, gCNR has promising potential to provide additional insight, particularly when designing new beamformers and image formation techniques and when reporting quantitative performance without an opportunity to qualitatively assess corresponding images (e.g., in text-only abstracts). (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3684 / 3698
页数:15
相关论文
共 50 条
  • [31] MAXIMIZATION OF CONTRAST-TO-NOISE RATIO TO DISTINGUISH DIFFUSION AND MICROCIRCULATORY FLOW
    MAKI, JH
    BENVENISTE, H
    MACFALL, JR
    JOHNSON, GA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01): : 39 - 46
  • [32] Signal-to-Noise Ratio and Contrast-to-Noise Ratio Measurements for Next Generation Tom osynthesis
    Martin, David A.
    Vent, Trevor L.
    Choi, Chloe J.
    Barufaldi, Bruno
    Acciavatti, Raymond J.
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [33] Quantitative evaluation of active thermography using contrast-to-noise ratio
    Svantner, M.
    Muzika, L.
    Chmelik, T.
    Skala, J.
    APPLIED OPTICS, 2018, 57 (18) : D49 - D55
  • [34] THE CONTRAST-TO-NOISE RATIO AS A MEASURE OF TISSUE CONTRAST IN MAGNETIC-RESONANCE-IMAGING
    BAIERL, P
    SEIDERER, M
    HEYWANG, S
    RATH, M
    DIGITALE BILDDIAGNOSTIK, 1986, 6 (03): : 101 - 110
  • [35] Grayscale contrast enhancement based on grayscale-based contrast-to-noise ratio
    Zhou, Wei
    Tian, Yi
    Cai, Xiaolu
    Fei, Zhenyu
    MEDICAL IMAGING 2021: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2021, 11599
  • [36] Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT
    Klintstrom, E.
    Smedby, O.
    Klintstrom, B.
    Brismar, T. B.
    Moreno, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (08)
  • [37] Validation of noise estimation for a clinical contrast-to-noise ratio for digital mammographic imaging
    Hill, Melissa L.
    Mackenzie, Alistair
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [38] Method for measuring contrast-to-noise ratio (CNR) in non-uniform image area on digital radiography
    Mori, Masaki
    Imai, Kuniharu
    Ikeda, Mitsuru
    Iida, Youko
    Ito, Fukiko
    Yoneda, Kazuo
    Enchi, Yukihiro
    IEEJ Transactions on Electronics, Information and Systems, 2011, 131 (11) : 1975 - 1982
  • [39] Contrast signal-to-noise ratio for image quality assessment
    Yao, S
    Lin, W
    Ong, E
    Lu, Z
    2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 441 - 444
  • [40] Impact of prone, supine and oblique patient positioning on CBCT image quality, contrast-to-noise ratio and figure of merit value in the maxillofacial region
    Koivisto, Juha
    van Eijnatten, Maureen
    Jarnstedt, Jorma
    Holli-Helenius, Kirsi
    Dastidar, Prasun
    Wolff, Jan
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (06)