Quantitative evaluation of active thermography using contrast-to-noise ratio

被引:20
|
作者
Svantner, M. [1 ]
Muzika, L. [1 ]
Chmelik, T. [1 ]
Skala, J. [1 ]
机构
[1] Univ West Bohemia, New Technol Res Ctr, Univ 8, Plzen 30614, Czech Republic
关键词
COMPOSITES; INSPECTION;
D O I
10.1364/AO.57.000D49
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Active thermography is an infrared-based technique for nondestructive testing of materials. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on the active thermography results' evaluation parameters and the contrast-to-noise ratio method, which can be used for quantitative evaluation of the results. Different result interpretation procedures are introduced. The influence of a selection method for indication and reference regions and the effect of image scaling on inspection results are discussed. (C) 2018 Optical Society of America
引用
下载
收藏
页码:D49 / D55
页数:7
相关论文
共 50 条
  • [1] The Generalized Contrast-to-Noise Ratio
    Rodriguez-Molares, Alfonso
    Rindal, Ole Marius Hoel
    D'hooge, Jan
    Masoy, Svein-Erik
    Austeng, Andreas
    Torp, Hans
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [2] An analysis of elastographic contrast-to-noise ratio
    Varghese, T
    Ophir, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 915 - 924
  • [3] The Contrast-to-Noise Ratio for Image Quality Evaluation in Scanning Electron Microscopy
    Timischl, F.
    SCANNING, 2015, 37 (01) : 54 - 62
  • [4] On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data
    Welvaert, Marijke
    Rosseel, Yves
    PLOS ONE, 2013, 8 (11):
  • [5] Evaluation of both image resolution and contrast-to-noise ratio in scanning electron microscopy
    Ishitani, Tohru
    Sato, Mitsugu
    JOURNAL OF ELECTRON MICROSCOPY, 2007, 56 (04) : 145 - 151
  • [6] A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    Baldelli, P.
    Phelan, N.
    Egan, G.
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2275 - 2285
  • [7] A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    P. Baldelli
    N. Phelan
    G. Egan
    European Radiology, 2009, 19 : 2275 - 2285
  • [8] Methods for Enhancing the Robustness of the Generalized Contrast-to-Noise Ratio
    Schlunk, Siegfried
    Byram, Brett C.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (08) : 831 - 842
  • [9] Contrast-to-noise ratio (CNR) as a quality parameter in fMRI
    Geissler, Alexander
    Gartus, Andreas
    Foki, Thomas
    Tahamtan, Amir Reza
    Beisteiner, Roland
    Barth, Markus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 1263 - 1270
  • [10] The Contrast-To-Noise Ratio Optimized Fluoroscopy Operation Logic
    Lin, P.
    Goode, A.
    Corwin, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E556 - E556