Application of the generalized contrast-to-noise ratio to assess photoacoustic image quality

被引:64
|
作者
Kempski, Kelley M. [1 ]
Graham, Michelle T. [2 ]
Gubbi, Mardava R. [2 ]
Palmer, Theron [1 ]
Bell, Muyinatu A. Lediju [1 ,2 ,3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
基金
美国国家科学基金会;
关键词
LAG SPATIAL COHERENCE;
D O I
10.1364/BOE.391026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The generalized contrast-to-noise ratio (gCNR) is a relatively new image quality metric designed to assess the probability of lesion detectability in ultrasound images. Although gCNR was initially demonstrated with ultrasound images, the metric is theoretically applicable to multiple types of medical images. In this paper, the applicability of gCNR to photoacoustic images is investigated. The gCNR was computed for both simulated and experimental photoacoustic images generated by amplitude-based (i.e., delay-and-sum) and coherence-based (i.e., short-lag spatial coherence) beamformers. These gCNR measurements were compared to three more traditional image quality metrics (i.e., contrast, contrast-to-noise ratio, and signal-to-noise ratio) applied to the same datasets. An increase in qualitative target visibility generally corresponded with increased gCNR. In addition, gCNR magnitude was more directly related to the separability of photoacoustic signals from their background, which degraded with the presence of limited bandwidth artifacts and increased levels of channel noise. At high gCNR values (i.e., 0.95-1), contrast, contrast-to-noise ratio, and signal-to-noise ratio varied by up to 23.7-56.2 dB, 2.0-3.4, and 26.5-7.6x10(20), respectively, for simulated, experimental phantom, and in vivo data. Therefore, these traditional metrics can experience large variations when a target is fully detectable, and additional increases in these values would have no impact on photoacoustic target detectability. In addition, gCNR is robust to changes in traditional metrics introduced by applying a minimum threshold to image amplitudes. In tandem with other photoacoustic image quality metrics and with a defined range of 0 to 1, gCNR has promising potential to provide additional insight, particularly when designing new beamformers and image formation techniques and when reporting quantitative performance without an opportunity to qualitatively assess corresponding images (e.g., in text-only abstracts). (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3684 / 3698
页数:15
相关论文
共 50 条
  • [41] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [42] Optimal beam quality selection based on contrast-to-noise ratio and mean glandular dose in digital mammography
    M. Aminah
    K. H. Ng
    B. J. J. Abdullah
    N. Jamal
    Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 329 - 334
  • [43] Optimal beam quality selection based on contrast-to-noise ratio and mean glandular dose in digital mammography
    Aminah, M.
    Ng, K. H.
    Abdullah, B. J. J.
    Jamal, N.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (04) : 329 - 334
  • [44] Blind Estimation for Localized Low Contrast-to-Noise Ratio BOLD Signals
    Atkinson, Ian C.
    Kamalabadi, Farzad
    Jones, Douglas L.
    Thulborn, Keith R.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2008, 2 (06) : 879 - 890
  • [45] Signal-to-noise ratio, contrast-to-noise ratio, and exposure time for imaging systems with photon-limited noise
    Lucke, Robert L.
    Kessel, Robert A.
    OPTICAL ENGINEERING, 2006, 45 (05)
  • [46] Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging
    Li, Xin
    Huang, Wei
    Rooney, William D.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1313 - 1322
  • [47] TOF Benefits and Trade-offs on Image Contrast-to-Noise Ratio Performance for a Small Animal PET Scanner
    Yussefian, Nikta Zarif
    Toussaint, Maxime
    Gaudin, Emilie
    Lecomte, Roger
    Fontaine, Rejean
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (05) : 687 - 693
  • [48] Effect of kVp on Noise, Dose, and Contrast-to-Noise Ratio for Pediatric Low-Dose CT
    Gamberoni, J.
    Dong, F.
    Davros, B.
    Reid, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [49] Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding
    Techavipoo, U
    Varghese, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 529 - 536
  • [50] Vessel Segmentation for Noisy CT Data with Quality Measure Based on Single-Point Contrast-to-Noise Ratio
    Nikonorov, A.
    Kolsanov, A.
    Petrov, M.
    Yuzifovich, Y.
    Prilepin, E.
    Chaplygin, S.
    Zelter, P.
    Bychenkov, K.
    E-BUSINESS AND TELECOMMUNICATIONS, ICETE 2015, 2016, 585 : 490 - 507