Semi-quantitative ventilation perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome

被引:35
|
作者
Jamadar, DA
Kazerooni, EA
Martinez, FJ
Wahl, RL
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Internal Med, Div Pulm & Crit Care Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Internal Med, Div Nucl Med, Ann Arbor, MI 48109 USA
关键词
emphysema; V Q scintigraphy; single-photon emission tomography; lung volume reduction surgery;
D O I
10.1007/s002590050444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ventilation/perfusion scans with single-photon emission tomography (SPET) were reviewed to determine their usefulness in the evaluation of lung volume reduction surgery (LVRS) candidates, and as a predictor of outcome after surgery. Fifty consecutive planar ventilation (Tc-99m-DTPA aerosol) and perfusion (Tc-99m-MAA) scans with perfusion SPET of patients evaluated for LVRS were retrospectively reviewed. Technical quality and the severity and extent of radiotracer defects in the upper and lower halves of the lungs were scored from visual inspection of planar scans and SPET data separately. An emphysema index (EI) (extent x severity) for the upper and lower halves of the lung, and an EI ratio for upper to lower lung were calculated for both planar and SPET scans. The ratios were compared with post-LVRS outcomes, 3, 6 and 12 months after surgery. All perfusion and SPET images were technically adequate. Forty-six percent of ventilation scans were not technically adequate due to central airway tracer deposition. Severity, extent, EI scores and EI ratios between perfusion and SPET were in good agreement (r = 0.52-0.68). The mean perfusion EI ratio was significantly different between the 30 patients undergoing bi-apical LVRS and the 17 patients excluded from LVRS (3.3+/-1.8 versus 1.2+/-0.7; P<0.0001), in keeping with the anatomic distribution of emphysema by which patients were selected for surgery by computed tomography (CT), The perfusion EI ratio correlated moderately with the change in FEV1 at 3 months (r = 0.37, P = 0.04), 6 months (r = 0.36, P = 0.05), and 12 months (r = 0.42, P = 0.03), and the transition dyspnea index at 6 months (r = 0.48, P = 0.014) after LVRS, It is concluded that patients selected to undergo LVRS have more severe and extensive apical perfusion deficits than patients not selected for LVRS, based on CT determination. SPET after aerosol V/Q imaging does nor add significantly to planar perfusion scans. Aerosol DTPA ventilation scans are not consistently useful. Perfusion lung scanning may be useful in selecting patients with successful outcomes after LVRS.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [1] Semi-quantitative ventilation/perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome
    David A. Jamadar
    Ella A. Kazerooni
    Fernando J. Martinez
    Richard L. Wahl
    European Journal of Nuclear Medicine, 1999, 26 : 734 - 742
  • [2] Perfusion scintigraphy in the evaluation for lung volume reduction surgery: Correlation with clinical outcome
    Wang, SC
    Fischer, KC
    Slone, RM
    Gierada, DS
    Yusen, RD
    Lefrak, SS
    Pilgram, TK
    Cooper, JD
    RADIOLOGY, 1997, 205 (01) : 243 - 248
  • [3] Ventilation/perfusion single-photon emission computed tomography: a service evaluation
    Parekh, Amit
    Graham, Richard
    Redman, Stewart
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (08) : 672 - 675
  • [4] Ventilation perfusion scintigraphy in the evaluation of patients for lung volume reduction surgery.
    Wang, SC
    Fischer, KC
    Slone, RM
    Gierada, DS
    Yusen, RD
    Cooper, JD
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 8 - 8
  • [5] Use of Ventilation-Perfusion Single-Photon Emission Computed Tomography to Select the Target Lobe for Endobronchial Valve Lung Volume Reduction
    Tee, Vanessa Sze Theen
    Nguyen, Phan
    Jersmann, Hubertus
    Grosser, Dion
    Crouch, Benjamin
    Lorraine, Brett
    Chew, Chong Ghee
    RESPIRATION, 2021, 100 (09) : 886 - 897
  • [6] Quantitative ventilation-perfusion imaging with SPECT in candidates for lung volume reduction surgery
    Jamadar, DA
    Kazerooni, EA
    Martinez, FJ
    Whyte, RI
    Wahl, RL
    RADIOLOGY, 1996, 201 : 200 - 200
  • [7] Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography
    Hentze, Benjamin
    Muders, Thomas
    Luepschen, Henning
    Maripuu, Enn
    Hedenstierna, Goran
    Putensen, Christian
    Walter, Marian
    Leonhardt, Steffen
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (06)
  • [8] Role of lung perfusion scintigraphy in relation to chest computed tomography and pulmonary function in the evaluation of candidates for lung volume reduction surgery
    Thurnheer, R
    Engel, H
    Weder, W
    Stammberger, U
    Laube, I
    Russi, EW
    Bloch, KE
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (01) : 301 - 310
  • [9] The conclusions drawn from ventilation/perfusion single-photon emission computed tomography compared with lung perfusion single-photon emission computed tomography and chest radiography in patients with suspected pulmonary thromboembolism
    Abubakar, Sofiullah
    Jacobs, Donovan
    Kotze, Tessa
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (10) : 908 - 914
  • [10] Preoperative perfusion lung scintigraphy in prediction of the outcome of lung volume reduction surgery in patients with emphysema.
    Hardoff, R
    Steinmetz, AP
    Krausz, Y
    Tamir, A
    Liani, M
    Bar-Sever, Z
    Kramer, M
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 129P - 129P