Semi-quantitative ventilation perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome

被引:35
|
作者
Jamadar, DA
Kazerooni, EA
Martinez, FJ
Wahl, RL
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Internal Med, Div Pulm & Crit Care Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Internal Med, Div Nucl Med, Ann Arbor, MI 48109 USA
关键词
emphysema; V Q scintigraphy; single-photon emission tomography; lung volume reduction surgery;
D O I
10.1007/s002590050444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ventilation/perfusion scans with single-photon emission tomography (SPET) were reviewed to determine their usefulness in the evaluation of lung volume reduction surgery (LVRS) candidates, and as a predictor of outcome after surgery. Fifty consecutive planar ventilation (Tc-99m-DTPA aerosol) and perfusion (Tc-99m-MAA) scans with perfusion SPET of patients evaluated for LVRS were retrospectively reviewed. Technical quality and the severity and extent of radiotracer defects in the upper and lower halves of the lungs were scored from visual inspection of planar scans and SPET data separately. An emphysema index (EI) (extent x severity) for the upper and lower halves of the lung, and an EI ratio for upper to lower lung were calculated for both planar and SPET scans. The ratios were compared with post-LVRS outcomes, 3, 6 and 12 months after surgery. All perfusion and SPET images were technically adequate. Forty-six percent of ventilation scans were not technically adequate due to central airway tracer deposition. Severity, extent, EI scores and EI ratios between perfusion and SPET were in good agreement (r = 0.52-0.68). The mean perfusion EI ratio was significantly different between the 30 patients undergoing bi-apical LVRS and the 17 patients excluded from LVRS (3.3+/-1.8 versus 1.2+/-0.7; P<0.0001), in keeping with the anatomic distribution of emphysema by which patients were selected for surgery by computed tomography (CT), The perfusion EI ratio correlated moderately with the change in FEV1 at 3 months (r = 0.37, P = 0.04), 6 months (r = 0.36, P = 0.05), and 12 months (r = 0.42, P = 0.03), and the transition dyspnea index at 6 months (r = 0.48, P = 0.014) after LVRS, It is concluded that patients selected to undergo LVRS have more severe and extensive apical perfusion deficits than patients not selected for LVRS, based on CT determination. SPET after aerosol V/Q imaging does nor add significantly to planar perfusion scans. Aerosol DTPA ventilation scans are not consistently useful. Perfusion lung scanning may be useful in selecting patients with successful outcomes after LVRS.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [31] Change in regional pulmonary perfusion as a result of posture and lung volume assessed using technetium-99m macroaggregated albumin single-photon emission tomography
    Shigeru Kosuda
    Hideo Kobayashi
    Shoichi Kusano
    European Journal of Nuclear Medicine, 2000, 27 : 529 - 535
  • [32] Quantitative analysis of lung function and airway remodeling using ventilation/perfusion single photon emission tomography/computed tomography and HRCT in patients with chronic obstructive pulmonary disease and asthma
    Hangyu Xie
    Zhen Zhao
    Wenjie Zhang
    Lin Li
    Annals of Nuclear Medicine, 2023, 37 : 504 - 516
  • [33] Quantitative analysis of lung function and airway remodeling using ventilation/perfusion single photon emission tomography/computed tomography and HRCT in patients with chronic obstructive pulmonary disease and asthma
    Xie, Hangyu
    Zhao, Zhen
    Zhang, Wenjie
    Li, Lin
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (09) : 504 - 516
  • [34] Prediction of Postoperative Cerebral Infarction after Cardiovascular Surgery Using Quantitative Measurement of Cerebral Blood Flow with Brain Single-Photon Emission Computed Tomography
    Tomoeda, Hiroshi
    Mikasa, Keita
    Chihara, Shingo
    Sawada, Kentaro
    Tanaka, Hiroyuki
    ANNALS OF VASCULAR DISEASES, 2018, 11 (04) : 511 - 519
  • [35] Quantitative Lung Ventilation Single-photon Emission Computed Tomography With Computed Tomography Scan (SPECT/CT) Using Technegas to Assess Early Small Airway Disease in Smokers: A Pilot Study
    Dube, B.
    Chatta, R.
    Leblond, A.
    Juneau, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [36] Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation
    Sazonova, S. I.
    Lishmanov, Yu. B.
    Batalov, R. E.
    Popov, S. V.
    Ilyushenkova, Yu. N.
    Rogovskaya, Yu. V.
    Idrisov, M. Z.
    TERAPEVTICHESKII ARKHIV, 2014, 86 (12): : 10 - 14
  • [37] Prediction of occult coronary artery disease in patients with normal myocardial perfusion scintigraphy using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera
    Shiraishi, S.
    Tsuda, N.
    Sakamoto, F.
    Yoshida, M.
    Tomiguchi, S.
    Yamashita, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S508 - S508
  • [38] Echocardiography versus 201Tl semi-quantitative gated single photon emission tomography for the evaluation of cardiac disease associated with late stage Duchenne muscular dystrophy
    Fujita, Atsushi
    Arahata, Hajime
    Sugawara, Miwa
    Watanabe, Akihiro
    Kawano, Yuji
    Sasagasako, Naokazu
    Fujii, Naoki
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2016, 19 (01): : 19 - 22
  • [39] Semi-quantitative dopamine transporter standardized uptake value in comparison with conventional specific binding ratio in [123I] FP-CIT single-photon emission computed tomography (DaTscan)
    Wakabayashi, Yuichi
    Takahashi, Ryuichi
    Kanda, Tomonori
    Zeng, Feibi
    Nogami, Munenobu
    Ishii, Kazunari
    Murakami, Takamichi
    NEUROLOGICAL SCIENCES, 2018, 39 (08) : 1401 - 1407
  • [40] Semi-quantitative dopamine transporter standardized uptake value in comparison with conventional specific binding ratio in [123I] FP-CIT single-photon emission computed tomography (DaTscan)
    Yuichi Wakabayashi
    Ryuichi Takahashi
    Tomonori Kanda
    Feibi Zeng
    Munenobu Nogami
    Kazunari Ishii
    Takamichi Murakami
    Neurological Sciences, 2018, 39 : 1401 - 1407