Semi-quantitative ventilation perfusion scintigraphy and single-photon emission tomography for evaluation of lung volume reduction surgery candidates: description and prediction of clinical outcome

被引:35
|
作者
Jamadar, DA
Kazerooni, EA
Martinez, FJ
Wahl, RL
机构
[1] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Med Ctr, Dept Internal Med, Div Pulm & Crit Care Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Internal Med, Div Nucl Med, Ann Arbor, MI 48109 USA
关键词
emphysema; V Q scintigraphy; single-photon emission tomography; lung volume reduction surgery;
D O I
10.1007/s002590050444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ventilation/perfusion scans with single-photon emission tomography (SPET) were reviewed to determine their usefulness in the evaluation of lung volume reduction surgery (LVRS) candidates, and as a predictor of outcome after surgery. Fifty consecutive planar ventilation (Tc-99m-DTPA aerosol) and perfusion (Tc-99m-MAA) scans with perfusion SPET of patients evaluated for LVRS were retrospectively reviewed. Technical quality and the severity and extent of radiotracer defects in the upper and lower halves of the lungs were scored from visual inspection of planar scans and SPET data separately. An emphysema index (EI) (extent x severity) for the upper and lower halves of the lung, and an EI ratio for upper to lower lung were calculated for both planar and SPET scans. The ratios were compared with post-LVRS outcomes, 3, 6 and 12 months after surgery. All perfusion and SPET images were technically adequate. Forty-six percent of ventilation scans were not technically adequate due to central airway tracer deposition. Severity, extent, EI scores and EI ratios between perfusion and SPET were in good agreement (r = 0.52-0.68). The mean perfusion EI ratio was significantly different between the 30 patients undergoing bi-apical LVRS and the 17 patients excluded from LVRS (3.3+/-1.8 versus 1.2+/-0.7; P<0.0001), in keeping with the anatomic distribution of emphysema by which patients were selected for surgery by computed tomography (CT), The perfusion EI ratio correlated moderately with the change in FEV1 at 3 months (r = 0.37, P = 0.04), 6 months (r = 0.36, P = 0.05), and 12 months (r = 0.42, P = 0.03), and the transition dyspnea index at 6 months (r = 0.48, P = 0.014) after LVRS, It is concluded that patients selected to undergo LVRS have more severe and extensive apical perfusion deficits than patients not selected for LVRS, based on CT determination. SPET after aerosol V/Q imaging does nor add significantly to planar perfusion scans. Aerosol DTPA ventilation scans are not consistently useful. Perfusion lung scanning may be useful in selecting patients with successful outcomes after LVRS.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 50 条
  • [21] Single photon emission tomography combined with computer tomography (SPECT/CT) for assessment of COPD patients for lung volume reduction surgery
    Lardinois, D.
    Rasch, H.
    Kneifel, S.
    Gambazzi, F.
    Tamm, M.
    Stolz, D.
    SWISS MEDICAL WEEKLY, 2008, 138 : 31S - 31S
  • [22] Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates
    Takenaka, Daisuke
    Ohno, Yoshiharu
    Koyama, Hisanobu
    Nogami, Munenobu
    Onishi, Yumiko
    Matsumoto, Keiko
    Yoshikawa, Takeshi
    Matsumoto, Sumiaki
    Sugimura, Kazuro
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : 465 - 472
  • [23] QUANTITATIVE THALLIUM SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY PREDICTS RISK FOR POOR OUTCOME IN THE EMORY ANGIOPLASTY SURGERY TRIAL
    ALAZRAKI, NP
    KRAWCZYNSKA, EG
    KOSINSKI, AS
    DEPUEY, EG
    ZIFFER, JA
    TAYLOR, AT
    PETRIGREW, RI
    VANSANT, JF
    CIRCULATION, 1995, 92 (08) : 2487 - 2487
  • [24] Lung Perfused Blood Volume Images With Dual-Energy Computed Tomography for Chronic Thromboembolic Pulmonary Hypertension: Correlation to Scintigraphy With Single-Photon Emission Computed Tomography
    Nakazawa, Tetsuro
    Watanabe, Yoshiyuki
    Hori, Yoshiro
    Kiso, Keisuke
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) : 590 - 595
  • [25] Functional lung volume mapping with perfusion Single-Photon Emission Computed Tomography scan for radiotherapy planning in patients with locally advanced nonsmall cell lung cancer
    Follacchio, Giulia Anna
    D'Urso, Pasqualina
    Cassese, Raffaele
    Ferrara, Carla
    Bulzonetti, Nadia
    Monteleone, Francesco
    Musio, Daniela
    Liberatore, Mauro
    Tombolini, Vincenzo
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (10) : 1026 - 1033
  • [26] Coronary artery disease diagnosis by magnetic resonance imaging: comparison of semi-quantitative assessment of myocardial perfusion after dipiridamol stress with single photon emission tomography
    Catalano, O
    Antonaci, S
    Moro, G
    Cannizzaro, G
    Frascaroli, M
    Baldi, M
    Tramarin, R
    EUROPEAN HEART JOURNAL, 2004, 25 : 42 - 42
  • [27] Quantitative analysis of lung function and airway remodeling using ventilation/perfusion single photon emission tomography/computed tomography in patients with chronic obstructive pulmonary disease and asthma
    Xie, Hangyu
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [28] Comparing Lung Perfusion Using Dual-Energy Computed Tomography and Single Photon Emission Computed Tomography in Patients with Severe Emphysema Prior to Bronchoscopic Lung Volume Reduction
    Olson, K.
    Tseng, S.
    Shamsid-Deen, N.
    Kang, P.
    Morris, M.
    Sue, R. D.
    Alalawi, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [29] Evaluation of ventilation and perfusion lung spect (single photon emission computed tomography) in the diagnosis of pulmonary embolism: preliminary results based on 100 cases
    Querellou, S.
    Guillo, P.
    Couturaud, F.
    Salaun, P.
    le Gal, G.
    Lacut, K.
    Oger, E.
    Leroyer, C.
    Mottier, D.
    le Duc-Pennec, A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 491 - 491
  • [30] Pilot study for comparative assessment of dual-energy computed tomography and single-photon emission computed tomography V/Q scanning for lung perfusion evaluation in infants
    Ramirez-Suarez, Karen, I
    Barrera, Christian A.
    Otero, Hansel J.
    Biko, David M.
    States, Lisa J.
    Servaes, Sabah
    Zhu, Xiaowei
    Davis, James C.
    Piccione, Joseph
    Rapp, Jordan B.
    PEDIATRIC PULMONOLOGY, 2022, 57 (03) : 702 - 710