Use of Ventilation-Perfusion Single-Photon Emission Computed Tomography to Select the Target Lobe for Endobronchial Valve Lung Volume Reduction

被引:4
|
作者
Tee, Vanessa Sze Theen [1 ,2 ]
Nguyen, Phan [1 ,2 ]
Jersmann, Hubertus [1 ,2 ]
Grosser, Dion [3 ]
Crouch, Benjamin [4 ]
Lorraine, Brett [5 ]
Chew, Chong Ghee [4 ]
机构
[1] Univ Adelaide, Fac Hlth & Med Sci, Sch Med, Adelaide, SA, Australia
[2] Royal Adelaide Hosp, Dept Thorac Med, Adelaide, SA, Australia
[3] ChestCare, Adelaide, SA, Australia
[4] Royal Adelaide Hosp, Dept Nucl Med, Adelaide, SA, Australia
[5] Royal Adelaide Hosp, SA Med Imaging, Adelaide, SA, Australia
关键词
Bronchoscopic lung volume reduction; Chronic obstructive pulmonary disease; Emphysema; Endobronchial valves; Bronchoscopy; Ventilation-perfusion scan; Single-photon emission computed tomography; Scintigraphy;
D O I
10.1159/000515336
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Quantitative planar ventilation-perfusion (VQ) has a complementary role in target lobe selection for endobronchial valve lung volume reduction (EBV-LVR), especially in homogenous disease. We investigated a novel method of lung lobar quantitation using VQ single-photon emission computed tomography (SPECT) with computed tomography (CT) to generate a parameter called the ventilation-perfusion differential index (VQDI). Aim: The aim of this study was to validate VQDI as a parameter for target lobe selection in EBV-LVR against the gold standard test of quantitative computed tomography (qCT). Methods: This study was a prospective, multi-centre, single-blinded, observational study of EBV-LVR patients. Baseline and 3-month post intervention VQ SPECT and qCT were performed. The target lobe was chosen using qCT and planar VQ report (CTTL) whilst blinded to VQDI. Post EBV-LVR, our nuclear physician, blinded to CTTL, selected a target lobe using deidentified VQDI (VQDI(TL)). Inter-rater agreement between CTTL and VQDI(TL) was calculated by Kappa statistic. Treatment outcomes were analysed with a linear mixed-effects model. Results: There was a high concordance between CTTL and VQDI(TL) in 16 patients (89%, Kappa statistic = 0.85). Post EBV-LVR, our subjects showed significant changes in FEV1 (mean difference [MD] +150 mL, p < 0.001), target lobe volume reduction (MD -973 mL, p < 0.001), residual volume (MD -800 mL, p < 0.001), and St. George's Respiratory Questionnaire score (MD -11, p = 0.001). Improvements in 6-minute walk distances did not reach statistical significance. Conclusion: In this study of treatment responders, EBV-LVR target lobe selection using VQDI concurs with qCT and thus supports its value for this purpose. It complements qCT and may potentially be of synergistic value especially in homogenous emphysema.
引用
收藏
页码:886 / 897
页数:12
相关论文
共 50 条
  • [1] USE OF VENTILATION-PERFUSION SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY (VQ SPECT) TO SELECT THE TARGET LOBE FOR ENDOBRONCHIAL VALVES LUNG VOLUME REDUCTION (EBV-LVR)
    Tee, V
    Nguyen, P.
    Grosser, D.
    Jersmann, H.
    Crouch, B.
    Lorraine, B.
    Chew, G.
    RESPIROLOGY, 2019, 24 : 52 - 52
  • [2] Use of Ventilation-Perfusion Single-Photon Emission Computed Tomography (VQ SPECT) to Select the Target Lobe for Endobronchial Valves Lung Volume Reduction (EBV-LVR)
    Tee, Vanessa
    Nguyen, Phan
    Grosser, Dion
    Jersmann, Hubertus
    Crouch, Benjamin
    Chew, Ghee
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [3] Ventilation/perfusion single-photon emission computed tomography: a service evaluation
    Parekh, Amit
    Graham, Richard
    Redman, Stewart
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (08) : 672 - 675
  • [4] Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography
    Hentze, Benjamin
    Muders, Thomas
    Luepschen, Henning
    Maripuu, Enn
    Hedenstierna, Goran
    Putensen, Christian
    Walter, Marian
    Leonhardt, Steffen
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (06)
  • [5] EXERCISE VENTILATION PERFUSION SCAN WITH SINGLE PHOTON EMISSION CT TO ASSESS TARGET LOBE FOR ENDOBRONCHIAL VALVE PLACEMENT
    Tseng, Steve
    Vick, Leigha
    Sue, Richard
    Alalawi, Raed
    CHEST, 2019, 156 (04) : 28A - 28A
  • [6] The conclusions drawn from ventilation/perfusion single-photon emission computed tomography compared with lung perfusion single-photon emission computed tomography and chest radiography in patients with suspected pulmonary thromboembolism
    Abubakar, Sofiullah
    Jacobs, Donovan
    Kotze, Tessa
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (10) : 908 - 914
  • [7] Discrepancy between Dual-Energy Computed Tomography Lung Perfusion Blood Volume and Lung Perfusion Single-Photon Emission Computed Tomography/Computed Tomography Images in Pulmonary Embolism
    Koike, Hirofumi
    Sueyoshi, Eijun
    Nagayama, Hiroki
    Ashizawa, Kazuto
    Sakamoto, Ichiro
    Uetani, Masataka
    Kudo, Takashi
    Ikeda, Satoshi
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189 (12) : E71 - E72
  • [8] Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation
    Nakashima, Masahiro
    Shinya, Takayoshi
    Oto, Takahiro
    Okawa, Tomoyo
    Takeda, Yoshihiro
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (07) : 703 - 710
  • [9] Impact of ventilation/perfusion single-photon emission computed tomography on treatment duration of pulmonary embolism
    Begic, Amela
    Opankovic, Emina
    Cukic, Vesna
    Rustempasic, Medzida
    Basic, Amila
    Miniati, Massimo
    Jogi, Jonas
    Bajc, Marika
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (02) : 162 - 167
  • [10] Myocardial perfusion with single-photon emission computed tomography, multidetector computed tomography, or neither?
    Raggi, Paolo
    Mancini, G. B. John
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) : 1722 - 1724