Voltammetry; Poly(4-(2-pyridylazo)-resorcinol); Glassy carbon electrode; Benserazide; Levodopa; SELECTIVE POTENTIOMETRIC SENSOR; PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROLYTIC-GRAPHITE ELECTRODE; SUGAR-INDUSTRY WASTE; TIN OXIDE ELECTRODE; BAGASSE FLY-ASH; DE-OILED-SOYA; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ZONE-ELECTROPHORESIS; POLYMERIC MEMBRANE ELECTRODES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple and highly sensitive method was investigated for the simultaneous determination of benserazide (BZ) and levodopa (LD) using Poly(4-(2-pyridylazo)-resorcinol) (PAR) modified glassy carbon electrodes. Both benserazide and levodopa were accumulated at the surface of the modified glassy carbon electrode (under open circuit condition for 30 s). In differential pulse voltammetry technique both BZ and LD were given sensitive oxidation peaks at 180 mV and 270 mV, respectively. Under the optimized experimental conditions (such as supporting electrolyte pH, accumulation time and scanning rate) BZ and LD were shown linear response over the range of 0.01-0.20 mM (r(2) = 0.991) and 0.025-0.4 mM (r(2) = 0.993), respectively. The lower detection limits were found to be 0.002 mM for BZ and 0.006 mM for LD. The commonly encountered excipients used in the pharmaceutical formulation showed no interference with the selective determination of BZ and LD. The investigated method showed good stability, reproducibility (1.3% (BZ) and 2.3% (LD)), repeatability (1.9%) and high recovery in pharmaceutical preparation (1.7% (BZ) and 2.7% (LD)), human serum (1.7% (BZ) and 1.9% (LD)) and urine samples (1.7% (BZ) and 1.8% (LD)).
引用
收藏
页码:297 / 311
页数:15
相关论文
共 50 条
  • [41] Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode
    Bruno R.L.Ferraz
    Tiago Guimar?es
    Demetrius Profeti
    Luciene P.R.Profeti
    Journal of Pharmaceutical Analysis, 2018, 8 (01) : 55 - 59
  • [42] Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode
    Ferraz, Bruno R. L.
    Guimaraes, Tiago
    Profeti, Demetrius
    Profeti, Luciene P. R.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2018, 8 (01) : 55 - 59
  • [43] Evaluation of a Nafion coated glassy carbon electrode for determination of paraquat by differential pulse voltammetry
    de Oliveira, UMF
    Lichtig, J
    Masini, JC
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (05) : 735 - 741
  • [44] Differential pulse anodic voltammetric determination of pantoprazole in pharmaceutical dosage forms and human plasma using glassy carbon electrode
    Erk, N
    ANALYTICAL BIOCHEMISTRY, 2003, 323 (01) : 48 - 53
  • [45] Simultaneous determination of mycophenolate mofetil and its active metabolite, mycophenolic acid, by differential pulse voltammetry using multi-walled carbon nanotubes modified glassy carbon electrode
    Madrakian, Tayyebeh
    Soleimani, Mohammad
    Afkhami, Abbas
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 42 : 38 - 45
  • [46] Simultaneous voltammetry detection of guanine and adenine in human serum with a CQDs / AuNPs @ MWCNTs modified glassy carbon electrode
    Jiang, Jiang
    Zhuang, Qizhao
    Deng, Shiting
    Kong, Dexian
    Chi, Yuwu
    Chinese Journal of Analysis Laboratory, 2021, 40 (12) : 1419 - 1424
  • [47] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    B. Muralidharan
    G. Gopu
    C. Vedhi
    P. Manisankar
    Journal of Applied Electrochemistry, 2009, 39 : 1177 - 1184
  • [48] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    Muralidharan, B.
    Gopu, G.
    Vedhi, C.
    Manisankar, P.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (08) : 1177 - 1184
  • [49] Nafion/Multiwalled Carbon Nanotubes/Mesoporous Silica Composite Modified Glassy Carbon Electrode for the Simultaneous Electrochemical Determination of Indigo Carmine and Carbendazim by Differential Pulse Voltammetry
    Fogang, Sengor Gabou
    Deffo, Gullit
    Guenang, Leopoldine Sonfack
    Temgoua, Ranil Clement Tonleu
    Njanja, Evangeline
    Tonle, Ignas Kenfack
    Bhaumik, Asim
    Ngameni, Emmanuel
    ANALYTICAL LETTERS, 2024, 57 (08) : 1241 - 1256
  • [50] A Selective Simultaneous Determination of Levodopa and Serotonin Using a Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite
    Babaei, Ali
    Babazadeh, M.
    ELECTROANALYSIS, 2011, 23 (07) : 1726 - 1735