Simultaneous Determination of Benserazide and Levodopa in Pharmaceutical Tablet, Human Serum and Urine Sample by Differential Pulse Voltammetry Using Modified Glassy Carbon Electrode

被引:0
|
作者
Naushad, Mu. [1 ]
Gupta, V. K. [2 ]
Wabaidur, S. M. [1 ]
Alothman, Z. A. [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Adv Mat Res Chair, Riyadh, 11451, Saudi Arabia
[2] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2013年 / 8卷 / 01期
关键词
Voltammetry; Poly(4-(2-pyridylazo)-resorcinol); Glassy carbon electrode; Benserazide; Levodopa; SELECTIVE POTENTIOMETRIC SENSOR; PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROLYTIC-GRAPHITE ELECTRODE; SUGAR-INDUSTRY WASTE; TIN OXIDE ELECTRODE; BAGASSE FLY-ASH; DE-OILED-SOYA; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ZONE-ELECTROPHORESIS; POLYMERIC MEMBRANE ELECTRODES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple and highly sensitive method was investigated for the simultaneous determination of benserazide (BZ) and levodopa (LD) using Poly(4-(2-pyridylazo)-resorcinol) (PAR) modified glassy carbon electrodes. Both benserazide and levodopa were accumulated at the surface of the modified glassy carbon electrode (under open circuit condition for 30 s). In differential pulse voltammetry technique both BZ and LD were given sensitive oxidation peaks at 180 mV and 270 mV, respectively. Under the optimized experimental conditions (such as supporting electrolyte pH, accumulation time and scanning rate) BZ and LD were shown linear response over the range of 0.01-0.20 mM (r(2) = 0.991) and 0.025-0.4 mM (r(2) = 0.993), respectively. The lower detection limits were found to be 0.002 mM for BZ and 0.006 mM for LD. The commonly encountered excipients used in the pharmaceutical formulation showed no interference with the selective determination of BZ and LD. The investigated method showed good stability, reproducibility (1.3% (BZ) and 2.3% (LD)), repeatability (1.9%) and high recovery in pharmaceutical preparation (1.7% (BZ) and 2.7% (LD)), human serum (1.7% (BZ) and 1.9% (LD)) and urine samples (1.7% (BZ) and 1.8% (LD)).
引用
收藏
页码:297 / 311
页数:15
相关论文
共 50 条
  • [31] Simultaneous determination of amlodipine and losartan using an iron metal-organic framework/mesoporous carbon nanocomposite-modified glassy carbon electrode by differential pulse voltammetry
    Rajpurohit, Anuja S.
    Bora, Dimple K.
    Srivastava, Ashwini K.
    ANALYTICAL METHODS, 2018, 10 (45) : 5423 - 5438
  • [32] Trace mercury determination by differential pulse anodic stripping voltammetry using polythiophene-quinoline/glassy carbon modified electrode
    Yoo, KS
    Woo, SB
    Jyoung, JY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (01) : 27 - 31
  • [33] The Determination of Riboflavin (Vitamin B2) Using Manganese Dioxide Modified Glassy Carbon Electrode by Differential Pulse Voltammetry
    Huang, De-Qian
    Wu, Hai
    Song, Chongfu
    Zhu, Qiangqiang
    Zhang, Hong
    Sheng, Liang-Quan
    Xu, Hua-Jie
    Liu, Zhao-Di
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 8303 - 8312
  • [34] Analysis of domperidone in pharmaceutical formulations and wastewater by differential pulse voltammetry at a glassy-carbon electrode
    M. S. El-Shahawi
    S. O. Bahaffi
    T. El-Mogy
    Analytical and Bioanalytical Chemistry, 2007, 387 : 719 - 725
  • [35] Differential Pulse Voltammetric Method for Determination of Acemetacin in Pharmaceutical Formulation using Glassy Carbon Electrode
    Moaaz, Eman M.
    Fayed, Ahmed S.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 358 - 370
  • [36] Determination of trace procaine hydrochloride by differential pulse adsorptive stripping voltammetry with a nafion modified glassy carbon electrode
    Li, NB
    Duan, JP
    Chen, GN
    ANALYTICAL SCIENCES, 2003, 19 (12) : 1587 - 1592
  • [37] Determination of Trace Procaine Hydrochloride by Differential Pulse Adsorptive Stripping Voltammetry with a Nafion Modified Glassy Carbon Electrode
    Nianbing Li
    Jianping Duan
    Guonan Chen
    Analytical Sciences, 2003, 19 : 1587 - 1592
  • [38] Analysis of domperidone in pharmaceutical formulations and wastewater by differential pulse voltammetry at a glassy-carbon electrode
    El-Shahawi, M. S.
    Bahaffi, S. O.
    El-Mogy, T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) : 719 - 725
  • [39] Simultaneous determination of lead and cadmium in water samples using differential pulse anodic stripping voltammetry at platinum nanoflowers modified glassy electrode
    Lieu, Nguyen Thi
    Hoang, Cao Van
    Le, Pham Thi Tuyet
    Giang, Le Truong
    VIETNAM JOURNAL OF CHEMISTRY, 2019, 57 (03) : 379 - 383
  • [40] DETERMINATION OF SOME DRUGS BY DIFFERENTIAL PULSE VOLTAMMETRY USING A ROTATING GLASSY-CARBON DISK ELECTRODE
    TAKAMURA, K
    INOUE, S
    IMAEDA, K
    KIKUCHI, M
    KUSU, F
    BUNSEKI KAGAKU, 1987, 36 (01) : 33 - 37