Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode

被引:28
|
作者
Ferraz, Bruno R. L. [1 ]
Guimaraes, Tiago [2 ]
Profeti, Demetrius [2 ]
Profeti, Luciene P. R. [2 ]
机构
[1] Univ Fed Espirito Santo, Dept Biol, BR-29500000 Alegre, ES, Brazil
[2] Univ Fed Espirito Santo, Dept Quim & Fis, BR-29500000 Alegre, ES, Brazil
关键词
Square-wave voltammetry; Sulfanilamide; Glassy carbon electrode; Biological fluids; LIQUID-CHROMATOGRAPHY; GRAPHITE ELECTRODE; ACID; FLUORESCENCE;
D O I
10.1016/j.jpha.2017.10.004
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
For the first time, sulfanilamide (SFD) was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode (GCE). The cyclic voltammetry (CV) experiments showed an irreversible oxidation peak at +1.06 V in 0.1 mol/L BRBS (pH = 2.0) at 50 mV/s. Different voltammetric scan rates (from 10 to 250 mV/s) suggested that the oxidation of SFD on the GCE was a diffusion controlled process. Square-wave voltammetry (SWV) method under optimized conditions showed a linear response to SFD from 5.0 to 74.7 mu mol/L. (R = 0.999) with detection and quantification limits of 0.92 and 3.10 mu mol/L, respectively. The developed SWV method showed better results for detection limit and linear range than the chronoamperometry method. It has been successfully applied to determine SFD concentration in pharmaceutical formulation, human urine and serum samples with recovery close to 100%. (C) 2018 Xi'an Jiaotong University. Production and hosting by Elsevier B.V.
引用
收藏
页码:55 / 59
页数:5
相关论文
共 50 条