DEVELOPMENT OF VOLTAMMETRIC TECHNIQUES FOR THE DETERMINATION OF SILODOSIN IN PHARMACEUTICAL FORMULATION AT GLASSY CARBON ELECTRODE

被引:0
|
作者
Toker, Berk [1 ]
Engin, E. R. [1 ]
Nevin, E. R. K. [1 ]
机构
[1] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
关键词
silodosin; voltammetry; glassy carbon electrode; first derivate spectrophotmetry; BIOLOGICAL-FLUIDS; DRUG; TABLETS; URINE; ASSAY; FORM;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study related to development of rapid, simple, sensitive and cost effective electrochemical and spectrophotometric methods for quantitative determination of silodosin (SLD) in pharmaceutical formulations. The electrochemical oxidation of SLD on glassy carbon electrode (GCE) was thorougly investigated by cyclic voltammetry and differential pulse voltammetry. The effect of scan rate, pH and concentration on the peak currents were investigated under the optimized experimental conditions for quantitative determination of SLD. The oxidation peak of SLD was observed on GCE at 696.0 mV in pH 2.0 BRT by using differential pulse voltammetry. The oxidation process was observed to be irreversible and diffusion-controlled. The obtained results were statistically compared with those of first derivative UV spectrophotometric method and the differences were found as insignificant.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 50 条
  • [1] Differential Pulse Voltammetric Method for Determination of Acemetacin in Pharmaceutical Formulation using Glassy Carbon Electrode
    Moaaz, Eman M.
    Fayed, Ahmed S.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 358 - 370
  • [2] Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode
    Ferraz, Bruno R. L.
    Guimaraes, Tiago
    Profeti, Demetrius
    Profeti, Luciene P. R.
    [J]. JOURNAL OF PHARMACEUTICAL ANALYSIS, 2018, 8 (01) : 55 - 59
  • [3] Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode
    Bruno R.L.Ferraz
    Tiago Guimar?es
    Demetrius Profeti
    Luciene P.R.Profeti
    [J]. Journal of Pharmaceutical Analysis, 2018, 8 (01) : 55 - 59
  • [4] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [5] VOLTAMMETRIC DETERMINATION OF ROPINIROLE AT GLASSY CARBON ELECTRODE EMPLOYING PULSED TECHNIQUES
    Bozal-Palabiyik, Burcin
    Uslu, Bengi
    [J]. REVUE ROUMAINE DE CHIMIE, 2017, 62 (6-7) : 559 - 567
  • [6] Voltammetric determination of cefpirome at multiwalled carbon nanotube modified glassy carbon sensor based electrode in bulk form and pharmaceutical formulation
    Jain, Rajeev
    Vikas
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 87 (02) : 423 - 426
  • [7] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    [J]. ANALYST, 2002, 127 (01) : 129 - 134
  • [8] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [9] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    [J]. 延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [10] A differential pulse voltammetric determination of nisoldipine using glassy carbon electrode in pharmaceutical preparations
    Dogrukol-Ak, D
    Gökören, N
    Tunçel, M
    [J]. ANALYTICAL LETTERS, 1998, 31 (01) : 105 - 116