VOLTAMMETRIC DETERMINATION OF ROPINIROLE AT GLASSY CARBON ELECTRODE EMPLOYING PULSED TECHNIQUES

被引:0
|
作者
Bozal-Palabiyik, Burcin [1 ]
Uslu, Bengi [1 ]
机构
[1] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
关键词
ropinirole; glassy carbon electrode; voltammetry; drug analysis; validation; PHARMACEUTICAL DOSAGE FORMS; LIQUID-CHROMATOGRAPHY; PARKINSONS-DISEASE; PASTE ELECTRODE; HUMAN PLASMA; HUMAN SERUM; DRUG; NANOPARTICLES; VALIDATION; IMPURITIES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study electrochemical studies were performed for ropinirole, which is used for the treatment of Parkinson's disease. In order to obtain rapid, simple and repeatable determination for ropinirole at glassy carbon electrode differential pulse voltammetry and square wave voltammetry were used. The oxidation behavior of this drug was analyzed with different supporting electrolytes between pH 0.3 - 12.0 by using cyclic voltammetry, differential pulse voltammetry and square wave voltammetry. The regression and the required validation parameters were studied in 0.1 M H2SO4 and pH 7.0 Britton-Robinson buffer solutions. Linearity was found between 8x10(-6) M and 2x10(-4) M for differential pulse and 4x10(-6) M and 2x10(-4) M for square wave voltammetry in 0.1 M H2SO4 with detection limits of 1.06x10(-6) M and 1.04x10(-6) M, respectively. Linear range was found 2x10(-6) - 6x10(-5) M for differential pulse and 4x10(-6) - 6x10(-5) M for square wave voltammetry in pH 7.0 BrittonRobinson buffer solution with detection limits of 4.73x10(-7) M and 2.65x10(-7) M, respectively. The applicability of developed techniques was shown through analyzing from pharmaceutical dosage forms and serum samples as well. Average recovery values were found between 99.65 % - 100.55 % which showed the accuracy of the developed techniques.
引用
收藏
页码:559 / 567
页数:9
相关论文
共 50 条
  • [1] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    [J]. ANALYST, 2002, 127 (01) : 129 - 134
  • [2] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [3] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    [J]. 延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [4] DEVELOPMENT OF VOLTAMMETRIC TECHNIQUES FOR THE DETERMINATION OF SILODOSIN IN PHARMACEUTICAL FORMULATION AT GLASSY CARBON ELECTRODE
    Toker, Berk
    Engin, E. R.
    Nevin, E. R. K.
    [J]. REVUE ROUMAINE DE CHIMIE, 2014, 59 (05) : 311 - 316
  • [5] Adsorptive Voltammetric Determination of Nimesulide at Glassy Carbon Electrode
    El-Sayed, Gamal O.
    Yasin, Shalaby A.
    El Ries, Mohammed A.
    El-Badawy, Azza A.
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2009, 28 (05): : 741 - 746
  • [6] Adsorptive voltammetric determination of orthophosphate at a glassy carbon electrode
    Tanaka, T
    Miura, M
    Ishiyama, T
    [J]. JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2001, 19 (04): : 591 - 599
  • [7] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    [J]. ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [8] VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL AT A GLASSY-CARBON ELECTRODE
    GUIJARRO, EC
    YANEZSEDENO, P
    CARRAZON, JMP
    DIEZ, LMP
    [J]. ANALYST, 1988, 113 (04) : 625 - 627
  • [9] VOLTAMMETRIC DETERMINATION OF PHENYLBUTAZONE AND OXYPHENBUTAZONE AT A GLASSY-CARBON ELECTRODE
    CHAN, HK
    FOGG, AG
    [J]. ANALYTICA CHIMICA ACTA, 1979, 109 (02) : 341 - 349
  • [10] Voltammetric determination of 5-methylcytosine at glassy carbon electrode
    Mendes, Carlos H. S.
    Silva, Maycom W. F.
    Oliveira, Severino Carlos B.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895