Validation of PRIMO Monte Carlo Model of Clinac®iX 6MV Photon Beam

被引:9
|
作者
Sarin, B. [1 ,2 ]
Bindhu, B. [1 ]
Saju, B. [2 ]
Nair, Raguram K. [2 ]
机构
[1] Noorul Islam Ctr Higher Educ, Dept Phys, Kanyakumari, Tamil Nadu, India
[2] Reg Canc Ctr, Div Radiat Phys, C Block,Room 3, Thiruvananthapuram 695011, Kerala, India
关键词
Clinac iX; Monte Carlo simulation; PENELOPE; PRIMO; DOSE-CALCULATION; DOSIMETRIC VALIDATION; SIMULATION; ALGORITHM; PENELOPE; CODE; XB;
D O I
10.4103/jmp.JMP_75_19
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aims to model 6MV photon of Clinac (R) iX linear accelerator using PRIMO Monte Carlo (MC) code and to assess PRIMO as an independent MC-based dose verification and quality assurance tool. Materials and Methods: The modeling of Clinac (R) iX linear accelerator has been carried out by using PRIMO simulation software (Version 0.3.1.1681). The simulated beam parameters were compared against the measured beam data of the Clinac (R) iX machine. The PRIMO simulation model of Clinac (R) iX was also validated against Eclipse (R) Acuros XB dose calculations in the case of both homogenous and inhomogeneous mediums. The gamma analysis method with the acceptance criteria of 2%, 2 mm was used for the comparison of dose distributions. Results: Gamma analysis shows a minimum pass percentage of 99% for depth dose curves and 95.4% for beam profiles. The beam quality index and output factors and absolute point dose show good agreement with measurements. The validation of PRIMO dose calculations, in both homogeneous and inhomogeneous medium, against Acuros (R) XB shows a minimum gamma analysis pass rate of 99%. Conclusions: This study shows that the research software PRIMO can be used as a treatment planning system-independent quality assurance and dose verification tool in daily clinical practice. Further validation will be performed with different energies, complex multileaf collimators fields, and with dynamic treatment fields.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 50 条
  • [21] Monte carlo model and output factors of elekta Infinity™ 6 and 10 MV photon beam
    Yani, Sitti
    Budiansah, Indra
    Rhani, Mohamad Fahdillah
    Haryanto, Freddy
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 470 - 478
  • [22] Accuracy of Monte Carlo software PRIMO against a reference dosimetry dataset for 6 MV photon beams
    Hermida-Lopez, M.
    Sanchez-Artunedo, D.
    Calvo-Ortega, J. F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S938 - S939
  • [23] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [24] Investigation of the RBE of radiation in the penumbra of a 6mv photon beam
    Syme, A.
    Kirkby, C.
    Mirzayans, R.
    MacKenzie, M.
    Field, C.
    Fallone, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S78 - S78
  • [25] A Monte Carlo model of an agility head for a 10-MV photon beam
    Almatani, Turki
    Hugtenburg, Richard P.
    Smakovs, Artjoms
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2022, 16 (01): : 300 - 307
  • [26] 6-MV Photon Beam Modeling for the Varian Clinac iX by Using the GEANT4 Virtual Jaw
    Kim, Byung Yong
    Kim, Hyung Dong
    Kim, Dong Ho
    Baek, Jong Geun
    Moon, Su Ho
    Rho, Gwang Won
    Kang, Jeong Ku
    Kim, Sung Kyu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 147 - 152
  • [27] 6-MV photon beam modeling for the Varian Clinac iX by using the Geant4 virtual jaw
    Byung Yong Kim
    Hyung Dong Kim
    Dong Ho Kim
    Jong Geun Baek
    Su Ho Moon
    Gwang Won Rho
    Jeong Ku Kang
    Sung Kyu Kim
    Journal of the Korean Physical Society, 2015, 67 : 147 - 152
  • [28] A comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs
    Mesbahi, A.
    Mehnati, P.
    Keshtkar, A.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (01): : 23 - 30
  • [29] MONTE CARLO STUDY OF THE OUT-OF-FIELD SPECTRA FOR 6MV AND 15MV PHOTON BEAMS WITH AND WITHOUT MLC.
    Theodorou, K.
    Paramerits, I.
    Tsiamas, P.
    Kappas, C.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S411 - S411
  • [30] VARIAN CLINAC 6 MeV Photon Spectra Unfolding using a Monte Carlo Meshed Model
    Morato, S.
    Juste, B.
    Miro, R.
    Verdu, G.
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153