Preparation of on-axis cylindrical trabecular bone specimens using micro-CT imaging

被引:24
|
作者
Wang, X [1 ]
Liu, XY [1 ]
Niebur, GL [1 ]
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46556 USA
关键词
trabecular bone; orthotropy; mechanical testing;
D O I
10.1115/1.1645866
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Orientation of trabecular bone specimens for mechanical testing must be carefully controlled. A method for accurately preparing on-axis cylindrical specimens using high-resolution micro-CT imaging was developed. Sixteen cylindrical specimens were prepared from eight bovine tibiae. High-revolution finite element models were generated from micro-CT images of parallelepipeds and used to determine the principal material coordinate system of each parallelepiped. A cylindrical specimen was then Machined with a diamond coring bit. The resulting specimens were scanned again to evaluate the orientation. The average deviation between the principal fabric orientation and the longitudinal axis of the cylindrical specimen was only 4.70+/-3.11degrees.
引用
收藏
页码:122 / 125
页数:4
相关论文
共 50 条
  • [21] Multislice-CT for structure - Analysis of trabecular bone - a comparison with Micro-CT and biomechanical strength
    Bauer, JS
    Issever, AS
    Fischbeck, M
    Burghardt, A
    Eckstein, F
    Rummeny, EJ
    Majumdar, S
    Link, TM
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05): : 709 - 718
  • [22] Biomechanical tests of osteoporotic vertebral trabecular bone using finite element analysis based on micro-CT
    Woo, Dae Gon
    Lee, Tae Woo
    Ko, Chang Yong
    Kim, Han Sung
    Won, Ye-Yeon
    2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2, 2006, : 231 - +
  • [23] Analysis of micro-vasculature in whole kidney specimens using micro-CT
    Sled, JG
    Marxen, M
    Henkelman, RM
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 53 - 64
  • [24] Extraction and Imaging of the Canine Acinus Using Micro-CT Imaging
    Coats, A.
    Hsia, C. C.
    Hoffman, E. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [25] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Tamminen, Inari S.
    Isaksson, Hanna
    Aula, Antti S.
    Honkanen, Eero
    Jurvelin, Jukka S.
    Kroger, Heikki
    JOURNAL OF BONE AND MINERAL METABOLISM, 2011, 29 (04) : 442 - 448
  • [26] Trabecular bone ratio of the mandibular condyle according to the presence of teeth: a micro-CT study
    D. Y. Choi
    K. H. Sun
    S. Y. Won
    J. G. Lee
    K. S. Hu
    K. D. Kim
    H. J. Kim
    Surgical and Radiologic Anatomy, 2012, 34 : 519 - 526
  • [27] Trabecular microarchitecture after fluoride therapy - Comparison of micro-CT and bone histology.
    Delling, G
    Bruder, J
    Engels, C
    Werner, M
    Minne, HW
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S426 - S426
  • [28] Characterization of Rotating Gantry Micro-CT Configuration for the In Vivo Evaluation of Murine Trabecular Bone
    Arentsen, Luke
    Hui, Susanta
    MICROSCOPY AND MICROANALYSIS, 2013, 19 (04) : 907 - 913
  • [29] Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status
    Inari S. Tamminen
    Hanna Isaksson
    Antti S. Aula
    Eero Honkanen
    Jukka S. Jurvelin
    Heikki Kröger
    Journal of Bone and Mineral Metabolism, 2011, 29 : 442 - 448
  • [30] The contribution of Micro-CT to the evaluation of trabecular bone at the posterior part of the auricular surface in men
    Deguette, Celine
    Chappard, Daniel
    Libouban, Helene
    Airagnes, Guillaume
    Rouge-Maillart, Clotilde
    Telmon, Norbert
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2018, 132 (04) : 1231 - 1239