Preparation of on-axis cylindrical trabecular bone specimens using micro-CT imaging

被引:24
|
作者
Wang, X [1 ]
Liu, XY [1 ]
Niebur, GL [1 ]
机构
[1] Univ Notre Dame, Dept Aerosp & Mech Engn, Notre Dame, IN 46556 USA
关键词
trabecular bone; orthotropy; mechanical testing;
D O I
10.1115/1.1645866
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Orientation of trabecular bone specimens for mechanical testing must be carefully controlled. A method for accurately preparing on-axis cylindrical specimens using high-resolution micro-CT imaging was developed. Sixteen cylindrical specimens were prepared from eight bovine tibiae. High-revolution finite element models were generated from micro-CT images of parallelepipeds and used to determine the principal material coordinate system of each parallelepiped. A cylindrical specimen was then Machined with a diamond coring bit. The resulting specimens were scanned again to evaluate the orientation. The average deviation between the principal fabric orientation and the longitudinal axis of the cylindrical specimen was only 4.70+/-3.11degrees.
引用
收藏
页码:122 / 125
页数:4
相关论文
共 50 条
  • [11] Bone mineral density measurements on cortical and trabecular specimens: Validation of a densitometric calibration protocol for in-vitro micro-CT
    Mecozzi, L.
    Stoico, R.
    Tassani, S.
    Particelli, F.
    Baruffaldi, F.
    Viceconti, M.
    BONE, 2011, 48 : S179 - S179
  • [12] Experimental Bone Biopsies Using Two Bone Biopsy Needles: Quantitative Micro-CT Analysis of Bone Specimens
    Park, Eun-Ah
    Hong, Sung Hwan
    Kim, Kwang Gi
    Choi, Ja-Young
    Shin, Chan Soo
    Kang, Heung Sik
    ACADEMIC RADIOLOGY, 2009, 16 (03) : 332 - 340
  • [13] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Ito, M
    JOURNAL OF BONE AND MINERAL METABOLISM, 2005, 23 (Suppl 1) : 115 - 121
  • [14] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Masako Ito
    Journal of Bone and Mineral Metabolism, 2005, 23 : 115 - 121
  • [15] On estimating the directionality distribution in pedicle trabecular bone from micro-CT images
    Gdyczynski, Catherine M.
    Manbachi, Amir
    Hashemi, SayedMasoud
    Lashkari, Bahman
    Cobbold, Richard S. C.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2415 - 2428
  • [16] Micro-CT Imaging of Rat Bone and Lumber Vertebra using Synchrotron Radiation
    Rao, Donepudi V.
    Cesareo, Roberto
    Brunetti, Antonio
    Akatsuka, Takao
    Yuasa, Tetsyua
    Takeda, Tohoru
    Tromba, Giuliana
    Gigante, Giovanni E.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 896 - +
  • [17] Characterization of Human Cortical and Trabecular Bone Structural Change by NMR and Micro-CT
    Ni, Qingwen
    Bredbenner, Todd
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 545 - 546
  • [18] Simulation of trabecular mineralization measurements in micro-CT
    Prevrhal, Sven
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [19] Trabecular bone structure of the calcaneus: Comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference
    Phan, CM
    Matsuura, M
    Bauer, JS
    Dunn, TC
    Newitt, D
    Lochmueller, EM
    Eckstein, F
    Majumdar, S
    Link, TM
    RADIOLOGY, 2006, 239 (02) : 488 - 496
  • [20] A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible
    Van Dessel, J.
    Huang, Y.
    Depypere, M.
    Rubira-Bullen, I.
    Maes, F.
    Jacobs, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)