Experimental Bone Biopsies Using Two Bone Biopsy Needles: Quantitative Micro-CT Analysis of Bone Specimens

被引:4
|
作者
Park, Eun-Ah [1 ]
Hong, Sung Hwan [1 ]
Kim, Kwang Gi [3 ]
Choi, Ja-Young [1 ]
Shin, Chan Soo [2 ]
Kang, Heung Sik [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Inst Radiat Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Internal Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Div Basic & Appl Sci, Biomed Engn Branch, Goyang Si, Gyeonggi Do, South Korea
关键词
Micro-computed tomography; bone histomorphometry; microstructure; trabecular thickness; bone biopsy; TRABECULAR BONE; MICROCOMPUTED TOMOGRAPHY; TEXTURE ANALYSIS; MICROARCHITECTURE; HISTOMORPHOMETRY; OSTEOPOROSIS; IMAGES; QUANTIFICATION; OSTEOMALACIA; CALCANEUS;
D O I
10.1016/j.acra.2008.09.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The aim of this study was to investigate whether samples obtained using two kinds of small trephines, 2.4 and 1.8 mm in inner diameter, are sufficient for the quantitative evaluation of metabolic bone disease using micro-computed tomographic (CT) three-dimensional parameter data sets. Materials and Methods. A total of 19 porcine lumbar vertebrae prior to biopsy and biopsy samples from the use of 2.4- and 1.8-mm trephines were examined using micro-CT imaging. For quantitative analysis, seven three-dimensional structural parameters, including trabecular bone volume, trabecular number, trabecular thickness, trabecular separation, the structure model index, the degree of anisotropy, and the trabecular bone pattern factor, were measured using CtAn software. The difference and agreement between the biopsy samples and the baseline vertebrae specimens before biopsy were assessed using paired t tests and Bland-Altman analysis, respectively. Results. There were no significant differences between the 2.4-mm samples and the baseline vertebrae specimens for trabecular bone volume, trabecular thickness, and trabecular number, with mean differences of -0.9%, 2.3%, and -3.1%, respectively; there was no significant difference between the 1.8-mm samples and the baseline vertebrae specimens only for trabecular thickness, with a mean difference of 1.9%. Conclusion. Samples taken from the use of the 2.4-mm trephine were better for quantitative analysis than those from the use of the 1.8-mm trephine and were acceptable for the quantitative evaluation of trabecular bone volume, trabecular thickness, and trabecular number.
引用
收藏
页码:332 / 340
页数:9
相关论文
共 50 条
  • [1] QUANTITATIVE MICRO-CT ANALYSIS OF BONE IN ZEBRAFISH FOR STUDIES OF OA
    Russell, R.
    Tsang, K.
    Harris, M.
    Aliprantis, A.
    Charles, J.
    Duryea, J.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 : A205 - A206
  • [2] Preparation of on-axis cylindrical trabecular bone specimens using micro-CT imaging
    Wang, X
    Liu, XY
    Niebur, GL
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 122 - 125
  • [3] Quantitative Micro-CT Analysis of Bone in Zebrafish: Accessing an Untapped Resource.
    Charles, Julia
    Henke, Katrin
    Tsang, Kelly
    Russell, Ruby
    Harris, Matthew P.
    Duryea, Jeffrey
    Aliprantis, Antonios
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S350 - S350
  • [4] Visualization of woven bone structure through analysis of biopsy specimens using synchrotron radiation and conventional X-ray micro-CT
    Kim, Y-G
    Seo, S-J
    HUMAN GENE THERAPY, 2019, 30 (11) : A167 - A167
  • [5] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [6] Evaluation of bone scaffolds by micro-CT
    F. Peyrin
    Osteoporosis International, 2011, 22 : 2043 - 2048
  • [7] Micro-CT for saw mark analysis on human bone
    Norman, D. G.
    Baier, W.
    Watson, G.
    Burnett, B.
    Painter, M.
    Williams, M. A.
    FORENSIC SCIENCE INTERNATIONAL, 2018, 293 : 91 - 100
  • [8] Evaluation of bone scaffolds by micro-CT
    Peyrin, F.
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 (06) : 2043 - 2048
  • [9] Expression of bone markers and micro-CT analysis of alveolar bone during orthodontic relapse
    Franzen, T. J.
    Monjo, M.
    Rubert, M.
    Vandevska-Radunovic, V.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2014, 17 (04) : 249 - 258
  • [10] Micro-CT examination of human bone: from biopsies towards the entire organ
    Perilli, Egon
    Parkinson, Ian H.
    Reynolds, Karen J.
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 75 - 82