Evaluation of Effects of Radiofrequency Ablation of Ex vivo Liver Using the 1-Fr Wire Electrode

被引:6
|
作者
Rustagi, Tarun [1 ]
Gleeson, Ferga C. [1 ]
Abu Dayyeh, Barham K. [1 ]
Topazian, Mark D. [1 ]
Levy, Michael J. [1 ]
机构
[1] Mayo Clin, Div Gastroenterol, 200 First St SW, Rochester, MN 55905 USA
关键词
EUS; RFA: hepatic; endoscopic; Habib; ablation; tumor; cancer; BARRETTS-ESOPHAGUS; FEASIBILITY; MANAGEMENT; TUMORS;
D O I
10.1097/MCG.0000000000000808
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Study Aims: Percutaneous and intraoperative radiofrequency ablation (RFA) has become a valued tool in the management of primary and secondary hepatic lesions. A recent FDA-approved endoscopic ultrasound (EUS)-guided RFA probe now offers promise to help manage such lesions. However, there are no data to determine the ideal power setting and duration of ablation needed to effectively treat hepatic masses. The aim of the study was to evaluate the macroscopic zone of hepatic injury for EUS-RFA using a variety of settings within a fresh porcine hepatic specimen. Methods: RFA was performed using the Habib EUS-RFA needle (EMcision Ltd, London, UK) which is a 1-Fr wire (0.33mm, 0.013 inch) with a working length of 190 cm. A step by step approach to deliver radiofrequency energy at 5, 10, 15, 20, and 50W of power and 10, 30, 60, 90, 120, and 300 seconds, respectively, was followed. Macroscopic and microscopic findings of the ablation zone were evaluated at each setting. Results: The maximal zone (diameter, 8.2 +/- 0.14 mm; length, 20.85 +/- 0.21 mm) of coagulative necrosis was achieved using an ablation power of 10W for duration of 90 seconds. Notably, increased power settings resulted in an unexpected and diminished effect on tissue destruction. Conclusions: Our findings support the use of 10W power for 90 seconds for maximum ablation in the liver. Our data also provide initial guidance and alternate settings to be considered when performing EUS-RFA to adjust the ablation power and duration to match the lesion size, shape, and risk of injury to adjacent structures.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [41] RADIOFREQUENCY ABLATION USING HYPERTONIC SALINE SOLUTION INSTILLATION: AN EX VIVO STUDY
    陈磊
    胡兵
    朱玲
    Medical Bulletin of Shanghai Jiaotong University, 2007, (02) : 147 - 150
  • [42] Percutaneous radiofrequency ablation therapy using a clustered electrode in the animal liver
    Horigome, H
    Nomura, T
    Saso, K
    Fujino, N
    Murasaki, G
    Kato, Y
    Kanematsu, T
    Joh, T
    Ohara, H
    Hashimoto, T
    Suzuki, T
    Itoh, M
    HEPATO-GASTROENTEROLOGY, 2001, 48 (37) : 163 - 165
  • [43] No-Touch Radiofrequency Ablation: A Comparison of Switching Bipolar and Switching Monopolar Ablation in Ex Vivo Bovine Liver
    Chang, Won
    Lee, Jeong Min
    Lee, Sang Min
    Han, Joon Koo
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (02) : 279 - 288
  • [44] Fluid-modulated bipolar radiofrequency ablation:: An ex-vivo evaluation study
    Bruners, P.
    Mueller, H.
    Guenther, R. W.
    Schmitz-Rode, T.
    Mahnken, A. H.
    ACTA RADIOLOGICA, 2008, 49 (03) : 258 - 266
  • [45] Moving-Shot versus Fixed Electrode Techniques for Radiofrequency Ablation: Comparison in an Ex-Vivo Bovine Liver Tissue Model
    Ha, Eun Ju
    Baek, Jung Hwan
    Lee, Jeong Hyun
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (06) : 836 - 843
  • [46] Radiofrequency liver tissue ablation with a "cooled-wet" electrode: In vivo results in the swine
    Ni, Y
    Miao, Y
    Vaninbroukx, J
    Dymarkowski, S
    Yu, J
    Marchal, GJ
    RADIOLOGY, 2000, 217 : 229 - 229
  • [47] Radiofrequency ablation of the porcine liver in vivo: Increased coagulation with an internally cooled perfusion electrode
    Lee, JM
    Han, JK
    Chang, JM
    Chung, SY
    Kim, SH
    Lee, JY
    Lee, MW
    Choi, BI
    ACADEMIC RADIOLOGY, 2006, 13 (03) : 343 - 352
  • [48] Evaluation of heat sink effect on microwave ablation using an ex vivo perfused porcine liver
    Ong, Seok Ling
    Gravante, Gianpiero
    Metcalfe, Matthew
    Lloyd, David
    Dennison, Ashley
    BRITISH JOURNAL OF SURGERY, 2014, 101 : 21 - 21
  • [49] Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model
    Pillai, Krishna
    Akhter, Javid
    Chua, Terence C.
    Shehata, Mena
    Alzahrani, Nayef
    Al-Alem, Issan
    Morris, David L.
    MEDICINE, 2015, 94 (09) : e580
  • [50] Temperature-dependent Electrode Repositioning for Multiple Overlapping Radiofrequency Ablation in Ex Vivo Porcine Livers
    Wong, Stephen N.
    Esperanza Santi, Grace
    Nurjadin, Hendra
    Aguilar, Redigo
    Gosalvez-Pe, Susana
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (11) : 1733 - 1738