Evaluation of Effects of Radiofrequency Ablation of Ex vivo Liver Using the 1-Fr Wire Electrode

被引:6
|
作者
Rustagi, Tarun [1 ]
Gleeson, Ferga C. [1 ]
Abu Dayyeh, Barham K. [1 ]
Topazian, Mark D. [1 ]
Levy, Michael J. [1 ]
机构
[1] Mayo Clin, Div Gastroenterol, 200 First St SW, Rochester, MN 55905 USA
关键词
EUS; RFA: hepatic; endoscopic; Habib; ablation; tumor; cancer; BARRETTS-ESOPHAGUS; FEASIBILITY; MANAGEMENT; TUMORS;
D O I
10.1097/MCG.0000000000000808
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Study Aims: Percutaneous and intraoperative radiofrequency ablation (RFA) has become a valued tool in the management of primary and secondary hepatic lesions. A recent FDA-approved endoscopic ultrasound (EUS)-guided RFA probe now offers promise to help manage such lesions. However, there are no data to determine the ideal power setting and duration of ablation needed to effectively treat hepatic masses. The aim of the study was to evaluate the macroscopic zone of hepatic injury for EUS-RFA using a variety of settings within a fresh porcine hepatic specimen. Methods: RFA was performed using the Habib EUS-RFA needle (EMcision Ltd, London, UK) which is a 1-Fr wire (0.33mm, 0.013 inch) with a working length of 190 cm. A step by step approach to deliver radiofrequency energy at 5, 10, 15, 20, and 50W of power and 10, 30, 60, 90, 120, and 300 seconds, respectively, was followed. Macroscopic and microscopic findings of the ablation zone were evaluated at each setting. Results: The maximal zone (diameter, 8.2 +/- 0.14 mm; length, 20.85 +/- 0.21 mm) of coagulative necrosis was achieved using an ablation power of 10W for duration of 90 seconds. Notably, increased power settings resulted in an unexpected and diminished effect on tissue destruction. Conclusions: Our findings support the use of 10W power for 90 seconds for maximum ablation in the liver. Our data also provide initial guidance and alternate settings to be considered when performing EUS-RFA to adjust the ablation power and duration to match the lesion size, shape, and risk of injury to adjacent structures.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [21] Computational Modeling of Radiofrequency Ablation: Evaluation on Ex Vivo Data Using Ultrasound Monitoring
    Audigier, Chloe
    Kim, Younsu
    Dillow, Austin
    Boctor, Emad M.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [22] Ex vivo experiment on radiofrequency liver ablation with saline infusion through a screw-tip cannulated electrode
    Miao, Y
    Ni, YC
    Mulier, S
    Wang, K
    Hoey, MF
    Mulier, P
    Penninckx, F
    Yu, J
    DeScheerder, I
    Baert, AL
    Marchal, G
    JOURNAL OF SURGICAL RESEARCH, 1997, 71 (01) : 19 - 24
  • [23] Quantification of Ablation Size in ex vivo Bovine Liver using Cool-Tip™ Radiofrequency Ablation System
    Mah, Y. H.
    Ng, K. H.
    Abdullah, B. J. J.
    Kwek, K. H.
    Wong, J. H. D.
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 615 - +
  • [24] In Vivo Evaluation of a Novel Radiofrequency Ablation Electrode in Pig Livers
    Cho, Sung-Hyun
    Oh, Dongwook
    Huh, Gunn
    Song, Tae-Jun
    Seo, Dong-Wan
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [25] Ex Vivo Experiment of Bovine Liver using Cool-Tip™ Radiofrequency Ablation System
    Mah, Y. H.
    Ng, K. H.
    Abdullah, B. J. J.
    Kwek, K. H.
    Wong, J. H. D.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 209 - +
  • [26] Experimental study of single-pin puncture asymmetrical hydroablation using a conformational radiofrequency ablation electrode in ex vivo ox liver
    Zhang, L.
    Zhou, Q.
    Fan, W-J
    Zhang, F-J
    Li, C-X
    Wu, P-H
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020): : E1179 - E1183
  • [27] Comparison of hydrochloric acid infusion radiofrequency ablation with microwave ablation in an ex vivo liver model
    Deng, Hanxia
    Zhang, Tianqi
    Jiang, Xiongying
    Huang, Senmiao
    Nan Nancy Jiang
    Lau, Wan-Yee
    Huang Jinhua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 600 - 607
  • [28] A Comparison of Direct Heating During Radiofrequency and Microwave Ablation in Ex Vivo Liver
    Anita Andreano
    Christopher L. Brace
    CardioVascular and Interventional Radiology, 2013, 36 : 505 - 511
  • [29] EX VIVO LIVER TISSUE RADIOFREQUENCY THERMAL ABLATION: IR MEASUREMENTS AND SIMULATIONS
    Macchi, Edoardo Gino
    Braschi, Giovanni
    Gallati, Mario
    FRONTIERS IN HEAT AND MASS TRANSFER, 2014, 5
  • [30] Standardization of a Radiofrequency Ablation Tool in an Ex-Vivo Porcine Liver Model
    Rossi, Gemma
    Petrone, Maria Chiara
    Capurso, Gabriele
    Albarello, Luca
    Testoni, Sabrina Gloria Giulia
    Archibugi, Livia
    Lena, Marco Schiavo
    Doglioni, Claudio
    Arcidiacono, Paolo Giorgio
    GASTROINTESTINAL DISORDERS, 2020, 2 (03): : 300 - 309