Evaluation of Effects of Radiofrequency Ablation of Ex vivo Liver Using the 1-Fr Wire Electrode

被引:6
|
作者
Rustagi, Tarun [1 ]
Gleeson, Ferga C. [1 ]
Abu Dayyeh, Barham K. [1 ]
Topazian, Mark D. [1 ]
Levy, Michael J. [1 ]
机构
[1] Mayo Clin, Div Gastroenterol, 200 First St SW, Rochester, MN 55905 USA
关键词
EUS; RFA: hepatic; endoscopic; Habib; ablation; tumor; cancer; BARRETTS-ESOPHAGUS; FEASIBILITY; MANAGEMENT; TUMORS;
D O I
10.1097/MCG.0000000000000808
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Study Aims: Percutaneous and intraoperative radiofrequency ablation (RFA) has become a valued tool in the management of primary and secondary hepatic lesions. A recent FDA-approved endoscopic ultrasound (EUS)-guided RFA probe now offers promise to help manage such lesions. However, there are no data to determine the ideal power setting and duration of ablation needed to effectively treat hepatic masses. The aim of the study was to evaluate the macroscopic zone of hepatic injury for EUS-RFA using a variety of settings within a fresh porcine hepatic specimen. Methods: RFA was performed using the Habib EUS-RFA needle (EMcision Ltd, London, UK) which is a 1-Fr wire (0.33mm, 0.013 inch) with a working length of 190 cm. A step by step approach to deliver radiofrequency energy at 5, 10, 15, 20, and 50W of power and 10, 30, 60, 90, 120, and 300 seconds, respectively, was followed. Macroscopic and microscopic findings of the ablation zone were evaluated at each setting. Results: The maximal zone (diameter, 8.2 +/- 0.14 mm; length, 20.85 +/- 0.21 mm) of coagulative necrosis was achieved using an ablation power of 10W for duration of 90 seconds. Notably, increased power settings resulted in an unexpected and diminished effect on tissue destruction. Conclusions: Our findings support the use of 10W power for 90 seconds for maximum ablation in the liver. Our data also provide initial guidance and alternate settings to be considered when performing EUS-RFA to adjust the ablation power and duration to match the lesion size, shape, and risk of injury to adjacent structures.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [31] A Comparison of Direct Heating During Radiofrequency and Microwave Ablation in Ex Vivo Liver
    Andreano, Anita
    Brace, Christopher L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (02) : 505 - 511
  • [32] Radiofrequency ablation of subcapsular lesions with internally cooled perfusion electrode: ex vivo study
    Kim, Myung Sub
    Hong, Hyun Pyo
    Kang, Kyung A.
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (02) : 216 - 222
  • [33] Algorithm Optimization for Multitined Radiofrequency Ablation: Comparative Study in ex Vivo and in Vivo Bovine Liver
    Appelbaum, Liat
    Sosna, Jacob
    Pearson, Robert
    Perez, Sarah
    Nissenbaum, Yizhak
    Mertyna, Pawel
    Libson, Eugene
    Goldberg, S. Nahum
    RADIOLOGY, 2010, 254 (02) : 430 - 440
  • [34] An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode
    Miao, Y
    Ni, YC
    Yu, J
    Zhang, H
    Baert, A
    Marchal, G
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1841 - 1847
  • [35] An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode
    Yi Miao
    Yicheng Ni
    Jie Yu
    Hao Zhang
    Albert Baert
    Guy Marchal
    European Radiology, 2001, 11 : 1841 - 1847
  • [36] Heat sink effects in thyroid bipolar radiofrequency ablation: an ex vivo study
    Klimek, Konrad
    Mader, Nicolai
    Happel, Christian
    Sabet, Amir
    Grunwald, Frank
    Groener, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [37] Heat sink effects in thyroid bipolar radiofrequency ablation: an ex vivo study
    Konrad Klimek
    Nicolai Mader
    Christian Happel
    Amir Sabet
    Frank Grünwald
    Daniel Groener
    Scientific Reports, 13
  • [38] Multipolar radiofrequency ablation using 4-6 applicators simultaneously: A study in the ex vivo bovine liver
    Stoffner, Rudolf
    Kremser, Christian
    Schullian, Peter
    Haidu, Marion
    Widmann, Gerlig
    Bale, Reto J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2568 - 2575
  • [39] Optimization of wet radiofrequency ablation using a perfused-cooled electrode:: A comparative study in Ex vivo bovine livers
    Lee, JM
    Han, JK
    Kim, SH
    Lee, Y
    Shin, KS
    Han, CJ
    Lee, MW
    Choi, JI
    Choi, BI
    KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (04) : 250 - 257
  • [40] Nakagami parametric image for evaluation of the degree of thermal denaturation inside porcine liver induced ex vivo by radiofrequency ablation
    Takeuchi, Michio
    Sakai, Toshihiko
    Oshima, Yusuke
    Kojima, Yasuhiro
    Mori, Kenji
    Omura, Masaaki
    Nagaoka, Ryo
    Hasegawa, Hideyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (SJ)