'Time apodization' of ultrasonic transducer arrays

被引:0
|
作者
Cincotti, G [1 ]
Cardone, G [1 ]
Gori, P [1 ]
Pomata, F [1 ]
Pappalardo, M [1 ]
机构
[1] Univ Roma Tre, Dipartimento Ingn Elettron, I-00146 Rome, Italy
关键词
transmit beamforming; apodization; contrast resolution;
D O I
10.1117/12.350664
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new apodization technique to enhance the contrast resolution of medical ultrasonic imaging systems is presented. It can easily be implemented on any commercial transducer array. The array aperture windowing in the transmitting mode is performed without modifying the driver voltage over the whole army, but only varying the driving pulse length from an element to another. A design curve has been determined which transforms any conventional amplitude apodization into a 'time apodization'. Experimental and numerical results are given for a 3.5 NHz convex array and for a 2.5 MHz phased array. They demonstrate the effectiveness of this method in reducing the off-axis energy ill the radiated pattern. Moreover, they point out that 'time apodization' improves also the range resolution, since the overall length of the ultrasonic pulse transmitted by the probe is reduced.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [21] Capacitive micromachined ultrasonic transducer arrays for minimally invasive medical ultrasound
    Chen, Jingkuang
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (02)
  • [22] 1-3 single crystal composites for ultrasonic transducer arrays
    Ritter, TA
    Shung, KK
    Park, SE
    Geng, X
    Shrout, TR
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1998, 1998, 3341 : 249 - 261
  • [23] Capacitive micromachined ultrasonic transducer arrays for integrated diagnostic/therapeutic catheters
    Wong, Serena H.
    Wygant, Ira O.
    Yeh, David T.
    Zhuang, Xuefeng
    Bayram, Baris
    Kupnik, Mario
    Oralkan, Omer
    Ergun, A. Sanli
    Yaralioglu, Goksen G.
    Khuri-Yakub, Butrus T.
    THERAPEUTIC ULTRASOUND, 2006, 829 : 395 - +
  • [24] Capacitive micromachined ultrasonic transducer arrays for medical imaging:: Experimental results
    Demirci, U
    Oralkan, Ö
    Johnson, JA
    Ergun, AS
    Karaman, M
    Khuri-Yakub, BT
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 957 - 960
  • [25] Underwater acoustic imaging using capacitive micromachined ultrasonic transducer arrays
    Oralkan, Ö
    Ergun, AS
    Cheng, CH
    Johnson, JA
    Karaman, M
    Khuri-Yakub, BT
    OCEANS 2002 MTS/IEEE CONFERENCE & EXHIBITION, VOLS 1-4, CONFERENCE PROCEEDINGS, 2002, : 2354 - 2360
  • [26] Asymmetric apodization applied to linear arrays
    Siu, GG
    Cheng, M
    Cheng, L
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (05) : 787 - 792
  • [27] Asymmetric apodization applied to linear arrays
    City Univ of Hong Kong, Kowloon, Hong Kong
    J Phys D, 5 (787-792):
  • [28] TIME-DELAY SPECTROMETRY FOR ULTRASONIC TRANSDUCER CHARACTERIZATION
    CHIVERS, RC
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1986, 19 (10): : 834 - 843
  • [29] Ultrasonic guided wave measurement in a wooden rod using shear transducer arrays
    Bakar, Adli Hasan Abu
    Legg, Mathew
    Konings, Daniel
    Alam, Fakhrul
    ULTRASONICS, 2022, 119
  • [30] Fabrication techniques for emproving the performance of PVDF-on-silicon ultrasonic transducer arrays
    Kim, Hyun-Joong
    Ziaie, Babak
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 834 - 837