'Time apodization' of ultrasonic transducer arrays

被引:0
|
作者
Cincotti, G [1 ]
Cardone, G [1 ]
Gori, P [1 ]
Pomata, F [1 ]
Pappalardo, M [1 ]
机构
[1] Univ Roma Tre, Dipartimento Ingn Elettron, I-00146 Rome, Italy
关键词
transmit beamforming; apodization; contrast resolution;
D O I
10.1117/12.350664
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new apodization technique to enhance the contrast resolution of medical ultrasonic imaging systems is presented. It can easily be implemented on any commercial transducer array. The array aperture windowing in the transmitting mode is performed without modifying the driver voltage over the whole army, but only varying the driving pulse length from an element to another. A design curve has been determined which transforms any conventional amplitude apodization into a 'time apodization'. Experimental and numerical results are given for a 3.5 NHz convex array and for a 2.5 MHz phased array. They demonstrate the effectiveness of this method in reducing the off-axis energy ill the radiated pattern. Moreover, they point out that 'time apodization' improves also the range resolution, since the overall length of the ultrasonic pulse transmitted by the probe is reduced.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [41] One-dimensional capacitative micromachined ultrasonic transducer arrays for echographic probes
    Cianci, E
    Minotti, A
    Foglietti, V
    Caliano, G
    Pappalardo, M
    MICROELECTRONIC ENGINEERING, 2004, 73-4 : 502 - 507
  • [42] APODIZATION IN THE TIME DOMAIN
    SERIES, GW
    JOURNAL DE PHYSIQUE II, 1992, 2 (04): : 615 - 620
  • [43] A stochastic approach for the apodization of very short arrays
    Repetto, S
    Trucco, A
    ULTRASONICS, 2004, 42 (1-9) : 425 - 429
  • [44] An ultrasonic flowmeter for liquid flow measurement in small pipes using AlN piezoelectric micromachined ultrasonic transducer arrays
    Zhu, Ke
    Chen, Xuying
    Qu, Mengjiao
    Yang, Dengfei
    Hu, Liang
    Xu, Jinghui
    Xie, Jin
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2020, 30 (12)
  • [45] Transducer module apodization to reduce bone heating during focused ultrasound uterine fibroid ablation with phased arrays: A numerical study
    Goudarzi, Sobhan
    Jones, Ryan Matthew
    Lee, Yin Hau Wallace
    Hynynen, Kullervo
    MEDICAL PHYSICS, 2024, : 8670 - 8687
  • [46] High Temperature Ultrasonic Transducer for Real-time Inspection
    Amini, Mohammad Hossein
    Sinclair, Anthony N.
    Coyle, Thomas W.
    Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 : 343 - 347
  • [47] Time domain self-reciprocity calibration of ultrasonic transducer
    Deng, MX
    Lin, JB
    Shui, YA
    ACTA PHYSICA SINICA-OVERSEAS EDITION, 1999, 8 : S48 - S52
  • [48] 2-D Crossed-electrode Transducer Arrays for Ultrasonic Particle Manipulation
    Wang, Han
    Qiu, Yongqiang
    Demore, Christine E. M.
    Gebhardt, Sylvia
    Cochran, Sandy
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [49] Investigation of the Suitability of Tissue Phantoms for Testing the Constancy of Ultrasonic Transducer Arrays in Quality Assurance
    Rosenfeld, E.
    Wolter, S.
    Kopp, A.
    Liebscher, E.
    ULTRASCHALL IN DER MEDIZIN, 2012, 33 (03): : 289 - 294
  • [50] Three-dimensional modelling of micromachined-ultrasonic-transducer arrays operating in water
    Wilm, M
    Reinhardt, A
    Laude, V
    Armati, R
    Daniau, W
    Ballandras, S
    ULTRASONICS, 2005, 43 (06) : 457 - 465