18k Channels single photon counting readout circuit for hybrid pixel detector

被引:53
|
作者
Maj, P. [1 ]
Grybos, P. [1 ]
Szczygiel, R. [1 ]
Zoladz, M. [1 ]
Sakumura, T. [2 ]
Tsuji, Y. [2 ]
机构
[1] AGH Univ Sci & Technol, Dept Measurements & Elect, PL-30059 Krakow, Poland
[2] Rigaku Corp, Xray Anal Div, Akishima, Tokyo 1968666, Japan
关键词
PXD18k; Hybrid Pixel Detector; Single Photon Counting; CHIP; PROTOTYPE; WORKING; DESIGN; NOISE; MODE;
D O I
10.1016/j.nima.2012.08.103
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have performed measurements of an integrated circuit named PXD18k designed for hybrid pixel semiconductor detectors used in X-ray imaging applications. The PXD18k integrated circuit, fabricated in CMOS 180 nm technology, has dimensions of 9.64 mm x 20 mm and contains approximately 26 million transistors. The core of the IC is a matrix of 96 x 192 pixels with 100 mu m x 100 um pixel size. Each pixel works in a single photon counting mode. A single pixel contains two charge sensitive amplifiers with Krummenacher feedback scheme, two shapers, two discriminators (with independent thresholds A and B) and two 16-bit ripple counters. The data are read out via eight low voltage differential signaling (LVDS) outputs with 100 Mbps rate. The power consumption is dominated by analog blocks and it is about 23 mu W/pixel. The effective peaking time at the discriminator input is 30 ns and is mainly determined by the time constants of the charge sensitive amplifier (CSA). The gain is equal to 42.5 mu V/e(-) and the equivalent noise charge is 168 e(-) rms (with bump-bonded silicon pixel detector). Thanks to the use of trim DACs in each pixel, the effective threshold spread at the discriminator input is only 1.79 mV. The dead time of the front end electronics for a standard setting is 172 ns (paralyzable model). In the standard readout mode (when the data collection time is separated from the time necessary to readout data from the chip) the PXD18k IC works with two energy thresholds per pixel. The PXD18k can also be operated in the continuous readout mode (with a zero dead time) where one can select the number of bits readout from each pixel to optimize the PXD18k frame rate. For example, for reading out 16 bits/pixel the frame rate is 2.7 kHz and for 4 bits/pixel it rises to 7.1 kHz. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [31] Readout chip for a 64 × 64 pixel matrix with 15-bit single photon counting
    Campbell, M.
    Heijne, E.H.M.
    Meddeler, G.
    Pernigotti, E.
    Snoeys, W.
    [J]. IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 751 - 753
  • [32] Readout for a 64 x 64 pixel matrix with 15-bit single Photon Counting
    Campbell, M
    Heijne, EHM
    Meddeler, G
    Pernigotti, E
    Snoeys, W
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 189 - 191
  • [33] Low noise single photon counting chip with energy window for hybrid pixel detector with precise offset and gain correction
    Maj, P.
    Grybos, P.
    Kmon, P.
    Szczygiel, R.
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [34] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Manach, E
    Ponchut, C
    Russo, P
    Tlustos, L
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3394 - 3398
  • [35] Design and Development of a Silicon Pixel Detector for a Single-Photon Counting Image Sensor
    Kim, Bonghoe
    Jeon, Sungchae
    Kim, Kihyun
    Huh, Young
    Jin, Seong Oh
    Kim, Jinyoung
    Jang, Namyoung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (05) : 2714 - 2718
  • [36] Counter architectures for a single photon-counting pixel detector such as Medipix3
    Wong, W.
    Ballabriga, R.
    Campbell, M.
    Llopart, X.
    Flustos, L.
    [J]. NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2007, 958 : 262 - 263
  • [37] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Maiorino, M
    Manach, E
    Mettivier, G
    Montesi, MC
    Ponchut, C
    Russo, P
    Tlustos, L
    Zwerger, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2379 - 2385
  • [38] Josephson readout electronics for the hybrid superconducting pixel detector
    Pagano, S
    Palmieri, VG
    Mukhanov, O
    Esposito, A
    [J]. JOURNAL DE PHYSIQUE IV, 1998, 8 (P3): : 147 - 153
  • [39] Characterization of a hybrid pixel counting detector using a silicon sensor and the IBEX readout ASIC for electron detection
    Fernandez-Perez, S.
    Boccone, V
    Broennimann, C.
    Disch, C.
    Piazza, L.
    Radicci, V
    Rissi, M.
    Schulze-Briese, C.
    Trueb, P.
    Zambon, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [40] Readout electronics for a Hybrid Avalanche Photon Detector
    Seljak, A.
    Adachi, I.
    Ikeda, H.
    Hara, K.
    Iijima, T.
    Iwata, S.
    Korpar, S.
    Krizan, P.
    Kuroda, E.
    Pestotnik, R.
    Nishida, S.
    Sumiyoshi, T.
    Takagaki, H.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6