Quadrupole pre-filter/mass filter transmission profiles: Experiment and simulation

被引:4
|
作者
Collings, Bruce A. [1 ]
机构
[1] SCIEX Ltd, 71 Four Valley Dr, Concord, ON L4K 4V8, Canada
关键词
MASS; ACCEPTANCE;
D O I
10.1002/rcm.8427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Quadrupole pre-filter transmission profiles are shown to be affected by the presence of trapped ions within the pre-filter of a quadrupole mass spectrometer. Trapped ions are the result of ions reflected at the pre-filter/mass filter boundary and lead to space charge effects that can affect the shape of the pre-filter transmission profile, ion beam stability, peak width and peak intensity. The development of high sensitivity mass spectrometers with bright ion beams leads to greater numbers of trapped ions. Methods Experimental pre-filter transmission profiles have been measured with and without an empty step to clear the pre-filter region of trapped ions showing the extent that space charge has on ion transmission through the pre-filter. Ion trajectory simulations, using a restricted set of initial conditions, have been used to help understand the structure of the pre-filter transmission profile. Results Experiments show that the effects of trapped ions within the pre-filter can be easily seen in the shape of the pre-filter transmission profile, ion beam stability and peak shape. The pre-filter transmission profile shows structure which is related to the secular frequency of the ion of interest which is related to the Mathieu parameter q of the pre-filter. Simulations show that the nodes observed in the experimental transmission profile are spaced by half the secular period of the ion. Conclusions The structure of the pre-filter transmission profile can be observed experimentally when steps are taken to remove trapped ions from within the pre-filter. A better understanding of the factors contributing to the shape of the pre-filter transmission profile from simulations has been demonstrated.
引用
收藏
页码:914 / 924
页数:11
相关论文
共 50 条
  • [21] TRANSMISSION OF A QUADRUPOLE MASS FILTER .2. CALCULATION OF THE OVERALL TRANSMISSION OF A QUADRUPOLE SPECTROMETER
    INGLEBERT, RL
    HENNEQUIN, JF
    REVUE DE PHYSIQUE APPLIQUEE, 1980, 15 (09): : 1489 - 1500
  • [22] Understanding the quadrupole mass filter through computer simulation
    Steel, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U413 - U413
  • [23] Computer simulation of the mass filter for a finite length quadrupole
    Tunstall, JJ
    Voo, ACC
    Taylor, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (02) : 184 - 188
  • [24] Understanding the quadrupole mass filter through computer simulation
    Steel, C
    Henchman, M
    JOURNAL OF CHEMICAL EDUCATION, 1998, 75 (08) : 1049 - 1054
  • [25] ''Organoclay'' pre-filter enhances GAC efficiency
    不详
    POLLUTION ENGINEERING, 1997, 29 (10) : 56 - 56
  • [26] A Wavelet Pre-Filter Scheme for MDS Tracking
    Macagnano, Davide
    de Abreu, Giuseppe Thadeu Freitas
    WPNC: 2009 6TH WORKSHOP ON POSITIONING, NAVIGATION AND COMMUNICATION, PROCEEDINGS, 2009, : 301 - 306
  • [27] Bad data pre-filter for state estimation
    Singh, D.
    Misra, R. K.
    Singh, V. K.
    Pandey, R. K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (10) : 1165 - 1174
  • [28] Fuel pre-filter funnel systems launched
    不详
    DIESEL PROGRESS NORTH AMERICAN EDITION, 2003, 69 (01): : 45 - 45
  • [29] THE TRANSMISSION PROPERTIES OF AN RF-ONLY QUADRUPOLE MASS FILTER
    MILLER, PE
    DENTON, MB
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (03): : 223 - 238
  • [30] Simulation study of a planar quadrupole mass filter for MEMS mass spectrometer
    Cheng, Yu -Peng
    Shen, Chen
    Wu, Zhang-Xu
    Li, Shan
    Liu, You-Jiang
    Wang, Han
    Chen, Chi-Lai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 52 (02)