Simulation study of a planar quadrupole mass filter for MEMS mass spectrometer

被引:1
|
作者
Cheng, Yu -Peng [1 ,2 ]
Shen, Chen [1 ,2 ]
Wu, Zhang-Xu [1 ,2 ]
Li, Shan [2 ]
Liu, You-Jiang [2 ]
Wang, Han [1 ,2 ]
Chen, Chi-Lai [2 ]
机构
[1] Univ Sci & Technol China, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
基金
国家重点研发计划;
关键词
Stacked-layer structure; Mass spectrometer chip; Ion trajectory simulation; High-pressure tolerance; Stability diagram; GAS-ANALYSIS; PERFORMANCE; FIELD;
D O I
10.1016/j.cjac.2024.100364
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micro-electro-mechanical system (MEMS) based mass spectrometry, MEMS mass spectrometry, emerges a new technique branch of miniature mass spectrometry. One of the main challenges hindering the development of MEMS mass spectrometry is the poor compatibility between the complex electrode structure of traditional ion optics and MEMS processes. This paper proposed a planar quadrupole mass filter utilizing a highly simplified stacked-layer structure and film electrodes, which is easy to fabricate with high precision by MEMS surface micromachining. The ion trajectory simulation model of the MEMS mass spectrometry chip involving all necessary ion optics was elaborated for investigating the preliminary performance of the planar quadrupole mass filter. By optimizing the crucial parameters such as the frequency of radio frequency voltage, the ratio of direct current voltage and radio frequency voltage, pre -pole length, main -pole length, and injection kinetic energy, the preliminary simulation result of planar quadrupole mass filter achieved a 1-2 Da peak width (at 50% of peak height) and 20-80% ion transmission efficiency. Importantly, the planar quadrupole mass filter demonstrated a maximum working pressure of 0.1 Pa (using air as the buffer gas), 100 times higher than that of conventional quadrupole mass filters, while maintaining a 0.7-1.8 Da peak width and similar to 5% ion transmission efficiency. Additionally, to modify the theoretical formulas for the non -ideal quadrupolar field of planar quadrupole mass filter, a novel approach based on stability diagrams obtained by simulation was also introduced. The pretty good linearity ( R2 = 1) between ion masses in the range of 10 to 100 Da and the corresponding radio frequency voltages was verified through the simulated mass spectra. Notably, the proportional coefficient of ion mass and radio frequency voltage exhibited a minimal 4% deviation between the simulated value (4.7132 V0P/Da) and the calculated value (4.9036 V0P/Da) through the modified formula. In conclusion, the preliminary simulation results demonstrated that the planar quadrupole mass filter possessed moderate performance, high -pressure tolerance, and excellent theoretical consistency, which proved it a promising technology of MEMS mass spectrometry. It can find applications in the fields of gas detection, including the rapid response to hazardous gas emissions and in situ detection of dissolved gases in the deep sea.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] MEMS quadrupole mass spectrometer
    Szyszka, Piotr
    Jendryka, Jakub
    Sobkow, Jan
    Zychla, Michal
    Bialas, Marcin
    Knapkiewicz, Pawel
    Dziuban, Jan
    Grzebyk, Tomasz
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 411
  • [2] MEMS QUADRUPOLE MASS SPECTROMETER
    Szyszka, Piotr
    Jendryka, Jakub
    Sobkow, Jan
    Zychla, Michal
    Bialas, Marcin
    Knapkiewicz, Pawel
    Dziuban, Jan
    Grzebyk, Tomasz
    2023 IEEE 36TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC, 2023, : 195 - 197
  • [3] Simulation of ion trajectories through the mass filter of a quadrupole mass spectrometer
    Ma, FM
    Taylor, S
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1996, 143 (01) : 71 - 76
  • [5] Mixture analysis using a quadrupole mass filter quadrupole ion trap mass spectrometer
    Jonscher, KR
    Yates, JR
    ANALYTICAL CHEMISTRY, 1996, 68 (04) : 659 - 667
  • [6] Detailed simulation of mass spectra for quadrupole mass spectrometer systems
    Gibson, JR
    Taylor, S
    Leck, JH
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2000, 18 (01): : 237 - 243
  • [7] Application of a static magnetic field to the mass filter of a quadrupole mass spectrometer
    Tunstall, JJ
    Taylor, S
    Vourdas, A
    Leck, JH
    Batey, J
    VACUUM, 1999, 53 (1-2) : 211 - 213
  • [8] Initial results for a quadrupole mass spectrometer with a silicon micromachined mass filter
    Taylor, S
    Tunstall, JJ
    Syms, RRA
    Tate, T
    Ahmad, MM
    ELECTRONICS LETTERS, 1998, 34 (06) : 546 - 547
  • [9] An out-of-plane MEMS quadrupole for a portable mass spectrometer
    Velasquez-Garcia, L. F.
    Akinwande, A. I.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [10] Transmission through the quadrupole mass spectrometer mass filter: The effect of aperture and harmonics
    Voo, ACC
    Ng, R
    Tunstall, JJ
    Taylor, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1997, 15 (04): : 2276 - 2281