Simulation study of a planar quadrupole mass filter for MEMS mass spectrometer

被引:1
|
作者
Cheng, Yu -Peng [1 ,2 ]
Shen, Chen [1 ,2 ]
Wu, Zhang-Xu [1 ,2 ]
Li, Shan [2 ]
Liu, You-Jiang [2 ]
Wang, Han [1 ,2 ]
Chen, Chi-Lai [2 ]
机构
[1] Univ Sci & Technol China, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
基金
国家重点研发计划;
关键词
Stacked-layer structure; Mass spectrometer chip; Ion trajectory simulation; High-pressure tolerance; Stability diagram; GAS-ANALYSIS; PERFORMANCE; FIELD;
D O I
10.1016/j.cjac.2024.100364
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micro-electro-mechanical system (MEMS) based mass spectrometry, MEMS mass spectrometry, emerges a new technique branch of miniature mass spectrometry. One of the main challenges hindering the development of MEMS mass spectrometry is the poor compatibility between the complex electrode structure of traditional ion optics and MEMS processes. This paper proposed a planar quadrupole mass filter utilizing a highly simplified stacked-layer structure and film electrodes, which is easy to fabricate with high precision by MEMS surface micromachining. The ion trajectory simulation model of the MEMS mass spectrometry chip involving all necessary ion optics was elaborated for investigating the preliminary performance of the planar quadrupole mass filter. By optimizing the crucial parameters such as the frequency of radio frequency voltage, the ratio of direct current voltage and radio frequency voltage, pre -pole length, main -pole length, and injection kinetic energy, the preliminary simulation result of planar quadrupole mass filter achieved a 1-2 Da peak width (at 50% of peak height) and 20-80% ion transmission efficiency. Importantly, the planar quadrupole mass filter demonstrated a maximum working pressure of 0.1 Pa (using air as the buffer gas), 100 times higher than that of conventional quadrupole mass filters, while maintaining a 0.7-1.8 Da peak width and similar to 5% ion transmission efficiency. Additionally, to modify the theoretical formulas for the non -ideal quadrupolar field of planar quadrupole mass filter, a novel approach based on stability diagrams obtained by simulation was also introduced. The pretty good linearity ( R2 = 1) between ion masses in the range of 10 to 100 Da and the corresponding radio frequency voltages was verified through the simulated mass spectra. Notably, the proportional coefficient of ion mass and radio frequency voltage exhibited a minimal 4% deviation between the simulated value (4.7132 V0P/Da) and the calculated value (4.9036 V0P/Da) through the modified formula. In conclusion, the preliminary simulation results demonstrated that the planar quadrupole mass filter possessed moderate performance, high -pressure tolerance, and excellent theoretical consistency, which proved it a promising technology of MEMS mass spectrometry. It can find applications in the fields of gas detection, including the rapid response to hazardous gas emissions and in situ detection of dissolved gases in the deep sea.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Simulation of ion-optical systems for mass spectrometers with a quadrupole mass filter
    A. A. Trubitsyn
    Technical Physics, 2003, 48 : 793 - 794
  • [32] Simulation of ion-optical systems for mass spectrometers with a quadrupole mass filter
    Trubitsyn, AA
    TECHNICAL PHYSICS, 2003, 48 (06) : 793 - 794
  • [33] Lateral Glow Discharge Ion Source for the Integrated MEMS Quadrupole Mass Spectrometer
    Szyszka, Piotr
    2024 37TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC 2024, 2024,
  • [35] A concept of MEMS mass spectrometer
    Szyszka, Piotr
    Grzebyk, Tomasz
    Gorecka-Drzazga, Anna
    Dziuban, Jan A.
    2018 XV INTERNATIONAL SCIENTIFIC CONFERENCE ON OPTOELECTRONIC AND ELECTRONIC SENSORS (COE), 2018,
  • [36] A study of the gas interference effects in quadrupole mass spectrometer
    Cheng Yongjun
    Dong Meng
    Sun Wenjun
    Zhang Suzhao
    Wang Xinghui
    Wu Xiangmin
    Zhao Lan
    Chen Lian
    Wu Chengyao
    Song Yi
    Zhang Ruifang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (06)
  • [37] A Quadrupole Mass Spectrometer for Resolution of Low Mass Isotopes
    Sreekumar, Jeyan
    Hogan, Thomas J.
    Taylor, Stephen
    Turner, Phillip
    Knott, Christopher
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (08) : 1364 - 1370
  • [38] MASS DISCRIMINATION EFFECTS IN A QUADRUPOLE MASS-SPECTROMETER
    WOOD, KV
    GRANGE, AH
    TAYLOR, JW
    ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1652 - 1654
  • [39] SIMPLIFIED SOLIDS MASS-SPECTROMETER COMBINING A GLOW-DISCHARGE SOURCE WITH A QUADRUPOLE MASS FILTER
    BRUHN, CG
    BENTZ, BL
    HARRISON, WW
    ANALYTICAL CHEMISTRY, 1978, 50 (02) : 373 - 375
  • [40] Simulation of the collisional cooling effect in a quadrupole ion trap mass spectrometer
    Wu, HF
    Chen, LW
    Lin, YP
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1999, 46 (06) : 923 - 932