Quadrupole pre-filter/mass filter transmission profiles: Experiment and simulation

被引:4
|
作者
Collings, Bruce A. [1 ]
机构
[1] SCIEX Ltd, 71 Four Valley Dr, Concord, ON L4K 4V8, Canada
关键词
MASS; ACCEPTANCE;
D O I
10.1002/rcm.8427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Quadrupole pre-filter transmission profiles are shown to be affected by the presence of trapped ions within the pre-filter of a quadrupole mass spectrometer. Trapped ions are the result of ions reflected at the pre-filter/mass filter boundary and lead to space charge effects that can affect the shape of the pre-filter transmission profile, ion beam stability, peak width and peak intensity. The development of high sensitivity mass spectrometers with bright ion beams leads to greater numbers of trapped ions. Methods Experimental pre-filter transmission profiles have been measured with and without an empty step to clear the pre-filter region of trapped ions showing the extent that space charge has on ion transmission through the pre-filter. Ion trajectory simulations, using a restricted set of initial conditions, have been used to help understand the structure of the pre-filter transmission profile. Results Experiments show that the effects of trapped ions within the pre-filter can be easily seen in the shape of the pre-filter transmission profile, ion beam stability and peak shape. The pre-filter transmission profile shows structure which is related to the secular frequency of the ion of interest which is related to the Mathieu parameter q of the pre-filter. Simulations show that the nodes observed in the experimental transmission profile are spaced by half the secular period of the ion. Conclusions The structure of the pre-filter transmission profile can be observed experimentally when steps are taken to remove trapped ions from within the pre-filter. A better understanding of the factors contributing to the shape of the pre-filter transmission profile from simulations has been demonstrated.
引用
收藏
页码:914 / 924
页数:11
相关论文
共 50 条
  • [31] Simulation of ion trajectories through the mass filter of a quadrupole mass spectrometer
    Ma, FM
    Taylor, S
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1996, 143 (01) : 71 - 76
  • [32] An Efficient Pre-filter to Accelerate Regular Expression Matching
    Xu, Chengcheng
    Chen, Shuhui
    Wang, Xiaofeng
    Su, Jinshu
    ALGORITHMS AND ARCHITECTURES FOR PARALLEL PROCESSING, ICA3PP 2015, 2015, 9532 : 111 - 119
  • [33] Face detection using skin segmentation as pre-filter
    Shobana, L.
    Yekkala, Anil Kr.
    Eajaz, Sameen
    Proceedings of the Sixth International Conference on Advances in Pattern Recognition, 2007, : 51 - 55
  • [34] ACCEPTANCE OF QUADRUPOLE MASS FILTER
    DAWSON, PH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1975, 17 (04): : 423 - 445
  • [35] Simulation of magneto-optical filter transmission profiles
    Severino, Giuseppe
    Oliviero, Maurizio
    Innocenti, Egidio Landi Degl'
    PHYSICS OF CHROMOSPHERIC PLASMAS, 2007, 368 : 617 - +
  • [36] IMPROVED QUADRUPOLE MASS FILTER
    BRUBAKER, WM
    VACUUM, 1967, 17 (03) : 166 - &
  • [37] TANDEM QUADRUPOLE MASS FILTER
    KONENKOV, NV
    SILAKOV, SS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (03) : 653 - 656
  • [38] IMPROVED QUADRUPOLE MASS FILTER
    BRUBAKER, WM
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1966, 3 (05): : 305 - &
  • [39] STUDY OF A QUADRUPOLE MASS FILTER USING COMPUTER SIMULATION.
    Zikes, Vaclav
    Tesla electronics, 1984, 17 (03): : 86 - 90
  • [40] Planar differential mobility spectrometer as a pre-filter for atmospheric pressure ionization mass spectrometry
    Schneider, Bradley B.
    Covey, Thomas R.
    Coy, Stephen L.
    Krylov, Evgeny V.
    Nazarov, Erkinjon G.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 298 (1-3) : 45 - 54