Development of EPID-based dosimetry for FFF-beam verification in radiation therapy

被引:2
|
作者
Thongsawad, S. [1 ]
Chanton, T. [2 ]
Saiyo, N. [1 ]
Udee, N. [2 ]
机构
[1] Chulabhorn Royal Acad, Dept Radiat Oncol, Bangkok, Thailand
[2] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok, Thailand
关键词
QUANTITATIVE-EVALUATION; ACQUISITION MODE; WATER;
D O I
10.1088/1742-6596/1285/1/012031
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this study was to develop Electronic Portal Imaging Devices (EPID)based dosimetry for Flattening-Filter-Free (FFF) beam verification. All radiation measurements were performed with source to imager distances (SID) of 150 cm to reduce saturation effect. EPID images were converted to radiation absorbed dose with our algorithm including four parameters: linearity of dose response with Monitor Unit (MU), beam profile correction, collimator scatter, and scatter kernel. The Calibration Units (CU) of image were scaled to dose ( Gy) by using linearity of dose response with MU. Off-axis response differences between EPID and water were reduced with beam profile correction. Scatter kernel was applied to EPID images to reduce the residual error. The algorithm accuracy was validated with 12 arcs of Volumetric Modulated Arc Therapy (VMAT) plans by using gamma analysis comparing between EPID-based dosimetry and a plane dose distribution of Treatment Planning Systems (TPS). Gamma Passing Rates (GPR) were used to determine the dose agreements with criteria of 2%, 2 mm and 3%, 3 mm. The mean of GPR was 97.91%, and 99.62% for criteria of 2%,2 mm and, 3%, 3 mm, respectively. Our EPID-based dosimetry showed good agreement with plane dose distribution in water. These results indicated that our EPID-based dosimetry can perform FFF-beam verification.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] An EPID-based Dosimetric Verification Tool for Electron Beam Therapy
    Ding, A.
    Han, B.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S921 - S921
  • [2] Development of An EPID-Based Output Measurement and Dosimetric Verification Tool for Electron Beam Therapy
    Ding, A.
    Han, B.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 331 - 331
  • [3] EPID-BASED DOSIMETRY
    Wendling, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S17 - S17
  • [4] Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy
    Ding, Aiping
    Xing, Lei
    Han, Bin
    [J]. MEDICAL PHYSICS, 2015, 42 (07) : 4190 - 4198
  • [5] EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams
    Miri, Narges
    Keller, Peter
    Zwan, Benjamin J.
    Greer, Peter
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 292 - 304
  • [6] Clinical Results of an EPID-Based In-vivo Dosimetry for Lung Cancer Radiation Therapy
    Giancaterino, Stefano
    De Nicola, Andrea
    Adorante, Nico
    Di Tommaso, Monica
    Trignani, Marianna
    Nuzzo, Marianna
    Genovesi, Domenico
    Falco, Maria Daniela
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S1510 - S1511
  • [7] Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy
    Nelms, Benjamin E.
    Rasmussen, Karl H.
    Tome, Wolfgang A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 140 - 157
  • [8] EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry Check™
    Chendi, Agnese
    Botti, Andrea
    Orlandi, Matteo
    Sghedoni, Roberto
    Iori, Mauro
    Cagni, Elisabetta
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 227 - 236
  • [9] Epid-based in vivo dosimetry for SBRT-VMAT treatment dose verification
    Cilla, S.
    Ianiro, A.
    Craus, M.
    Viola, P.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Grusio, M.
    Deodato, F.
    Macchia, G.
    Valentini, V.
    Morganti, A.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S772 - S773
  • [10] Evaluation of interfraction setup variations for postmastectomy radiation therapy using EPID-based in vivo dosimetry
    Kang, Shengwei
    Li, Jie
    Ma, Jiabao
    Zhang, Wei
    Liao, Xiongfei
    Qing, Hou
    Tan, Tingqiang
    Xin, Xin
    Tang, Bin
    Piermattei, Angelo
    Orlandini, Lucia Clara
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 43 - 52