Development of EPID-based dosimetry for FFF-beam verification in radiation therapy

被引:2
|
作者
Thongsawad, S. [1 ]
Chanton, T. [2 ]
Saiyo, N. [1 ]
Udee, N. [2 ]
机构
[1] Chulabhorn Royal Acad, Dept Radiat Oncol, Bangkok, Thailand
[2] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok, Thailand
关键词
QUANTITATIVE-EVALUATION; ACQUISITION MODE; WATER;
D O I
10.1088/1742-6596/1285/1/012031
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this study was to develop Electronic Portal Imaging Devices (EPID)based dosimetry for Flattening-Filter-Free (FFF) beam verification. All radiation measurements were performed with source to imager distances (SID) of 150 cm to reduce saturation effect. EPID images were converted to radiation absorbed dose with our algorithm including four parameters: linearity of dose response with Monitor Unit (MU), beam profile correction, collimator scatter, and scatter kernel. The Calibration Units (CU) of image were scaled to dose ( Gy) by using linearity of dose response with MU. Off-axis response differences between EPID and water were reduced with beam profile correction. Scatter kernel was applied to EPID images to reduce the residual error. The algorithm accuracy was validated with 12 arcs of Volumetric Modulated Arc Therapy (VMAT) plans by using gamma analysis comparing between EPID-based dosimetry and a plane dose distribution of Treatment Planning Systems (TPS). Gamma Passing Rates (GPR) were used to determine the dose agreements with criteria of 2%, 2 mm and 3%, 3 mm. The mean of GPR was 97.91%, and 99.62% for criteria of 2%,2 mm and, 3%, 3 mm, respectively. Our EPID-based dosimetry showed good agreement with plane dose distribution in water. These results indicated that our EPID-based dosimetry can perform FFF-beam verification.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Characterization of a new EPID-based system for in-vivo dosimetry in VMAT treatments
    Bresciani, S.
    Poli, M.
    Miranti, A.
    Maggio, A.
    Di Dia, A.
    Bracco, C.
    Stasi, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S736 - S737
  • [32] EPID-based daily verification of reproducibility of patients' irradiation with IMRT plans
    Kruszyna-Mochalska, Marta
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (05) : 309 - 314
  • [33] Development and implementation of an EPID-based method for localizing isocenter
    Hyer, Daniel E.
    Mart, Christopher J.
    Nixon, Earl
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 72 - 81
  • [34] Evaluation of a water equivalent EPID model for flattening filter free (FFF) beam transit dosimetry
    Deshpande, S.
    Blake, S.
    Holloway, L.
    Vial, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S961 - S962
  • [35] EPID-Based in Vivo Dosimetry: The Next Step in Patient-Specific QA
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Mans, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [36] MLC positioning verification for small fields: a new investigation into automatic EPID-based verification methods
    Joshua Hiatt
    Godfrey Mukwada
    Michael Barnes
    Hans Lynggaard Riis
    Du Huynh
    Pejman Rowshanfarzad
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 945 - 955
  • [37] Development of an EPID-Based Machine and IMRT QA System
    Chen, X.
    Shi, C.
    Buckey, C.
    Stathakis, S.
    Alkhatib, H.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2010, 37 (06) : 3154 - +
  • [38] A convolutional neural network model for EPID-based non-transit dosimetry
    Bosco, Lucas Dal
    Franceries, Xavier
    Romain, Blandine
    Smekens, Francois
    Husson, Francois
    Le Lann, Marie-Veronique
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [39] EPID-based 3D in vivo dosimetry in head and neck radiotherapy
    Biltekin, F.
    Yazici, G.
    Ozyigit, G.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1354 - S1355
  • [40] Real-Time EPID-Based Dose Verification System for Detection of Gross Radiation Treatment Delivery Errors
    Greer, P.
    Fuangrod, T.
    Woodruff, H.
    Rowshanfarzad, P.
    van Uytven, E.
    McCurdy, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S120 - S121