Detection of E-coli in beach water within 1 hour using immunomagnetic separation and ATP bioluminescence

被引:59
|
作者
Lee, JY [1 ]
Deininger, RA [1 ]
机构
[1] Univ Michigan, Sch Publ Hlth, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
关键词
Escherichia coli; beach; immunomagnetic separation; ATP bioluminescence; rapid method;
D O I
10.1002/bio.753
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The contamination of beach waters occurs from the discharge of storm water and sanitary sewer overflows containing faecal material. Additional faecal material derives from discharge of animals and waterfowl. In order to protect public from exposure to faecal-contaminated water, it is required to test enteric indicators in beach water. The problem is that the traditional culture-based methods cannot meet this goal because it takes too long (>24 h), so the results are not available until a day later. A rapid method for testing beach water for Escherichia coli within 1 h has been developed. Immunomagnetic separation (IMS) and ATP bioluminescence were used for selective capture and quantification, respectively. This rapid method was compared to the current method (m-TEC) using beach water samples. The beach samples were prefiltered with a 20 mum pore size filter in order to remove algae, plant debris and large particles. The results showed that the prefiltration step did not trap the bacteria which were present in the original water samples. The prefiltered water was then passed through a 0.45 mum pore size filter for concentration. The deposited bacteria were resuspended and then mixed with superparamagnetic polystyrene beads (diameter of 0.6 mum) that were coated with E. coli antibodies. After IMS, the quantification of the E. coli was done by ATP bioluminescence. The results obtained with IMS-ATP bioluminescence correlated well with the plate count method (Rsq = 0.93). The detection limit of the assay was about 20 CFU/100 mL, which is well below the US EPA limits for recreational water. The entire procedure can be completed in less than 1 hour. The necessary equipment is portable and was tested on-site. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [11] Mobile E-coli Detection Using Microwave Technique
    Aziz, S. Z.
    Jamlos, M. F.
    Ramli, Nordin
    Jamlos, M. A.
    [J]. 2014 IEEE REGION 10 SYMPOSIUM, 2014, : 435 - 439
  • [12] Power Analysis of Photonic Sensor for Detection of E-coli in Water
    Shaikh, Afzal
    Sharan, Preeta
    Devi, Manju
    [J]. 2019 WORKSHOP ON RECENT ADVANCES IN PHOTONICS (WRAP), 2019,
  • [13] Fast detection of Escherichia coli in food using nanoprobe and ATP bioluminescence technology
    Zhang, Zhijie
    Wang, Chunxing
    Zhang, Liren
    Meng, Qingtian
    Zhang, Yuemin
    Sun, Fang
    Xu, Yuanda
    [J]. ANALYTICAL METHODS, 2017, 9 (36) : 5378 - 5387
  • [14] An E-coli screening machine in water via fluorescence detection
    Juhong, Aniwat
    Piyawattanametha, Wibool
    [J]. 2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [15] A chemiluminescence fiber-optic biosensor coupled with immunomagnetic separation for rapid detection of E-coli O15:H7
    Ye, J
    Liu, Y
    Li, Y
    [J]. TRANSACTIONS OF THE ASAE, 2002, 45 (02): : 473 - 478
  • [16] A Microfluidic Device for Rapid Screening of E-coli O157:H7 Based on IFAST and ATP Bioluminescence Assay for Water Analysis
    Ngamsom, Bongkot
    Truyts, Alma
    Fourie, Louis
    Kumar, Shavon
    Tarn, Mark D.
    Iles, Alexander
    Moodley, Klariska
    Land, Kevin J.
    Pamme, Nicole
    [J]. CHEMISTRY-A EUROPEAN JOURNAL, 2017, 23 (52) : 12754 - 12757
  • [17] Detection of E-coli in water using semi-conducting polymeric thin film sensor
    Dixit, Vivechana
    Tewari, Jagdish C.
    Sharma, Bindu S.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01): : 96 - 103
  • [18] Quantitative determination of Escherichia coli in water using CHROMagar(R) E-coli
    Alonso, JL
    Amoros, I
    Chong, S
    Garelick, H
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 1996, 25 (03) : 309 - 315
  • [19] Comparison of three different media for the detection of E-coli and coliforms in water
    Bernasconi, C.
    Volponi, G.
    Bonadonna, L.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2006, 54 (03) : 141 - 145
  • [20] A microfluidic impedance biosensor based on immunomagnetic separation and urease catalysis for continuous-flow detection of E-coli O157:H7
    Yao, Lan
    Wang, Lei
    Huang, Fengchun
    Cai, Gaozhe
    Xi, Xinge
    Lin, Jianhan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 259 : 1013 - 1021