A Microfluidic Device for Rapid Screening of E-coli O157:H7 Based on IFAST and ATP Bioluminescence Assay for Water Analysis

被引:15
|
作者
Ngamsom, Bongkot [1 ]
Truyts, Alma [2 ]
Fourie, Louis [2 ]
Kumar, Shavon [2 ]
Tarn, Mark D. [1 ]
Iles, Alexander [1 ]
Moodley, Klariska [2 ]
Land, Kevin J. [2 ]
Pamme, Nicole [1 ]
机构
[1] Univ Hull, Sch Math & Phys Sci, Cottingham Rd, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] CSIR, Meiring Naude Rd, ZA-0184 Pretoria, South Africa
关键词
ATP assays; E; coli; immunoassays; luminescence; water chemistry; IN-SITU HYBRIDIZATION; SOLID-PHASE CYTOMETRY; DRINKING-WATER; SURFACE-TENSION; BACTERIA; SAMPLES; FLOW; AMPLIFICATION; ENUMERATION; CAPTURE;
D O I
10.1002/chem.201703487
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We present a simple microfluidic system for rapid screening of Escherichia coli (E.coli) O157:H7 employing the specificity of immunomagnetic separation (IMS) via immiscible filtration assisted by surface tension (IFAST), and the sensitivity of the subsequent adenosine triphosphate (ATP) assay by the bioluminescence luciferin/luciferase reaction. The developed device was capable of detecting E.coli O157:H7 from just 6 colony forming units (CFU) in 1mL spiked buffer within 20 min. When tested with wastewater discharged effluent samples, without pre-concentration, the device demonstrated the ability to detect 10(4)CFU per mL seeded; suggesting great potential for point-of-need microbiological water quality monitoring.
引用
收藏
页码:12754 / 12757
页数:4
相关论文
共 50 条
  • [1] On the trial of E-coli O157:H7
    Lewis, R
    [J]. SCIENTIST, 1999, 13 (21): : 10 - 10
  • [2] Validation of a Modified ANSR® for E-coli O157:H7 Method for Detection of E-coli O157:H7 in Select Foods
    Alles, Susan
    Roman, Brooke
    Quynh-Nhi Le
    Hosking, Edan
    Colangelo, Wesley
    Tovar, Eric
    Biswas, Preetha
    Mozola, Mark
    Donofrio, Robert
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (01) : 96 - 107
  • [3] The Wishaw E-coli O157:H7 outbreak
    Kohli, HS
    [J]. NATIONAL MEDICAL JOURNAL OF INDIA, 1997, 10 (03): : 145 - 146
  • [4] THE BEHAVIOR OF E-COLI O157:H7 IN SUCUK
    Apaydin, Guezin
    Ceylan, Ziya Goekalp
    Kaya, Muekerrem
    [J]. JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2009, 33 (06) : 827 - 836
  • [5] Recognizing E-coli O157:H7 infection
    Greenwald, DA
    Brandt, LJ
    [J]. HOSPITAL PRACTICE, 1997, 32 (04): : 123 - &
  • [6] E-coli O157:H7;: A European perspective
    Duffy, G
    Garvey, P
    Sheridan, JJ
    [J]. IRISH JOURNAL OF AGRICULTURAL AND FOOD RESEARCH, 2000, 39 (02) : 173 - 182
  • [7] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (03): : 309 - 316
  • [8] Sheep as an important source of E-coli O157/O157:H7 in Turkey
    Gencay, Yilmaz Emre
    [J]. VETERINARY MICROBIOLOGY, 2014, 172 (3-4) : 590 - 595
  • [9] E-coli O157:H7 in water:: a public health problem.
    Vernozy-Rozand, C
    Montet, MP
    Ray-Gueniot, S
    [J]. REVUE DE MEDECINE VETERINAIRE, 2002, 153 (04) : 235 - 242
  • [10] The epidemiology of verocytotoxigenic E-coli O157:H7 in Ireland
    Igoe, D
    [J]. IRISH VETERINARY JOURNAL, 2001, 54 (05) : 239 - 242