Detection of E-coli in beach water within 1 hour using immunomagnetic separation and ATP bioluminescence

被引:59
|
作者
Lee, JY [1 ]
Deininger, RA [1 ]
机构
[1] Univ Michigan, Sch Publ Hlth, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
关键词
Escherichia coli; beach; immunomagnetic separation; ATP bioluminescence; rapid method;
D O I
10.1002/bio.753
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The contamination of beach waters occurs from the discharge of storm water and sanitary sewer overflows containing faecal material. Additional faecal material derives from discharge of animals and waterfowl. In order to protect public from exposure to faecal-contaminated water, it is required to test enteric indicators in beach water. The problem is that the traditional culture-based methods cannot meet this goal because it takes too long (>24 h), so the results are not available until a day later. A rapid method for testing beach water for Escherichia coli within 1 h has been developed. Immunomagnetic separation (IMS) and ATP bioluminescence were used for selective capture and quantification, respectively. This rapid method was compared to the current method (m-TEC) using beach water samples. The beach samples were prefiltered with a 20 mum pore size filter in order to remove algae, plant debris and large particles. The results showed that the prefiltration step did not trap the bacteria which were present in the original water samples. The prefiltered water was then passed through a 0.45 mum pore size filter for concentration. The deposited bacteria were resuspended and then mixed with superparamagnetic polystyrene beads (diameter of 0.6 mum) that were coated with E. coli antibodies. After IMS, the quantification of the E. coli was done by ATP bioluminescence. The results obtained with IMS-ATP bioluminescence correlated well with the plate count method (Rsq = 0.93). The detection limit of the assay was about 20 CFU/100 mL, which is well below the US EPA limits for recreational water. The entire procedure can be completed in less than 1 hour. The necessary equipment is portable and was tested on-site. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [21] Application of Immunomagnetic Separation to E. coli O157: H7 Detection
    Tang Qian-qian
    Wang Jian-ping
    Ye Zun-zhong
    Gai Ling
    Ying Yi-bin
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (10) : 2614 - 2618
  • [22] Detection of water-borne E-coli O157 using the integrating waveguide biosensor
    Zhu, PX
    Shelton, DR
    Karns, JS
    Sundaram, A
    Li, SH
    Amstutz, P
    Tang, CM
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (04): : 678 - 683
  • [23] Biochip using a biofluidic system for detection of E-coli and other pathogens
    Stokes, DL
    Allain, L
    Griffin, GD
    Mobley, J
    Stratis-Cullum, DN
    Wintenberg, AL
    Maples, RA
    Vo-Dinh, T
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS, 2003, 4958 : 13 - 21
  • [24] Optical Fiber Biosensor toward E-coli Bacterial Detection on the Pollutant Water
    Fallah, Hoorieh
    Asadishad, Tannaz
    Parsanasab, Gholam M.
    Harun, Sulaiman Wadi
    Mohammed, Waleed S.
    Yasin, Moh
    [J]. ENGINEERING JOURNAL-THAILAND, 2021, 25 (12): : 1 - 8
  • [25] Mobile Water Kit 2.0: A Field Deployable Solution for E-coli Detection in Potable Water
    Gunda, N. S. K.
    Chavali, R.
    Mitra, S. K.
    [J]. CHEMICAL SENSORS 12: CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL SYSTEMS, 2016, 75 (16): : 315 - 318
  • [26] Detection of E-coli using a microfluidics-based antibody biochip detection system
    Stokes, DL
    Griffin, GD
    Vo-Dinh, T
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4): : 295 - 301
  • [27] Immunomagnetic Separation and Visual Fluorescence Detection of E. coli O157 Using AOAC Approved SAS™ Molecular Tests
    Bapanpally, Chandra
    Maganty, Gayatri
    Khan, Shah
    Kasra, Akif
    Morey, Amit
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1073 - 1077
  • [28] Structure and arrangement of the δ subunit in the E-coli ATP synthase (ECF1F0)
    Wilkens, S
    Rodgers, A
    Ogilvie, I
    Capaldi, RA
    [J]. BIOPHYSICAL CHEMISTRY, 1997, 68 (1-3) : 95 - 102
  • [29] Use of two presence/absence systems for the detection of E-coli and coliforms from water
    Fricker, EJ
    Fricker, CR
    [J]. WATER RESEARCH, 1996, 30 (09) : 2226 - 2228
  • [30] Quantitative determination of E-coli and fecal coliforms in water using a chromogenic medium
    Alonso, JL
    Soriano, K
    Amoros, I
    Ferrus, MA
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 1998, 33 (06): : 1229 - 1248