Stereotactic CT-Guided Percutaneous Microwave Ablation of Liver Tumors With the Use of High-Frequency Jet Ventilation: An Accuracy and Procedural Safety Study

被引:71
|
作者
Engstrand, Jennie [1 ]
Toporek, Grzegorz [2 ]
Harbut, Piotr [1 ]
Jonas, Eduard [1 ]
Nilsson, Henrik [1 ]
Freedman, Jacob [1 ]
机构
[1] Danderyd Hosp AB, Danderyd Hosp, Dept Clin Sci, Karolinska Inst, SE-18288 Stockholm, Sweden
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
关键词
accuracy; interventional radiology; liver; microwave ablation; stereotaxy; RADIOFREQUENCY ABLATION; HEPATIC-TUMORS; HEPATOCELLULAR-CARCINOMA; NAVIGATION SYSTEM; THERMAL ABLATION; GUIDANCE; PHANTOM; BIOPSY; THERMOABLATION; FEASIBILITY;
D O I
10.2214/AJR.15.15803
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS. Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS. Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [+/- SD] lesion diameter, 14.9 +/- 5.9 mm; mean lesion location depth, 87.5 +/- 27.3 mm). The antennae were placed with a mean lateral error of 4.0 +/- 2.5 mm, a depth error of 3.4 +/- 3.2 mm, and a total error of 5.8 +/- 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 +/- 556.5 mGy x cm, but medical personnel were not exposed to irradiation. CONCLUSION. Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the -needle. Therefore, it is technically feasible and applicable for safe treatments.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [1] CT-guided Navigation of Percutaneous Hepatic and Renal Radiofrequency Ablation under High-frequency Jet Ventilation: Feasibility Study
    Abderhalden, Susanne
    Biro, Peter
    Hechelhammer, Lukas
    Pfiffner, Roger
    Pfammatter, Thomas
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (09) : 1275 - 1278
  • [2] Safety of CT-Guided Microwave Ablation of Subcardiac Liver Tumors
    Johnson, William
    Weekley, Adam
    Suz, Pilar
    Parikh, Nainesh
    El-Haddad, Ghassan
    Mhaskar, Rahul
    Kis, Bela
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (11) : 1693 - 1700
  • [3] Safety of CT-Guided Microwave Ablation of Subcardiac Liver Tumors
    William Johnson
    Adam Weekley
    Pilar Suz
    Nainesh Parikh
    Ghassan El-Haddad
    Rahul Mhaskar
    Bela Kis
    CardioVascular and Interventional Radiology, 2022, 45 : 1693 - 1700
  • [4] Use of High-Frequency Jet Ventilation for Percutaneous Tumor Ablation
    Denys, Alban
    Lachenal, Yann
    Duran, Rafael
    Chollet-Rivier, Madeleine
    Bize, Pierre
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (01) : 140 - 146
  • [5] Use of High-Frequency Jet Ventilation for Percutaneous Tumor Ablation
    Alban Denys
    Yann Lachenal
    Rafael Duran
    Madeleine Chollet-Rivier
    Pierre Bize
    CardioVascular and Interventional Radiology, 2014, 37 : 140 - 146
  • [6] CT-guided percutaneous microwave ablation of pulmonary malignant tumors
    Ko, Wei-Chun
    Lee, Yee-Fan
    Chen, Yi-Chang
    Chien, Ning
    Huang, Yu-Sen
    Tseng, Yao-Hui
    Lee, Jang-Ming
    Hsu, Hsao-Hsun
    Chen, Jin-Shing
    Chang, Yeun-Chung
    JOURNAL OF THORACIC DISEASE, 2016, 8 : S659 - S665
  • [7] CT-Guided Percutaneous Microwave Ablation of Tumors in the Hepatic Dome: Assessment of Efficacy and Safety
    Asvadi, Nazanin H.
    Anvari, Arash
    Uppot, Raul N.
    Thabet, Ashraf
    Zhu, Andrew X.
    Arellano, Ronald S.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (04) : 496 - 502
  • [8] Technical and safety performance of CT-guided percutaneous microwave ablation for lung tumors: an ablate and resect study
    Blackmon, Shanda H.
    Sterner, Rosalie M.
    Eiken, Patrick W.
    Vogl, Thomas J.
    Pua, Bradley B.
    Port, Jeffrey L.
    Dupuy, Damian E.
    Callstrom, Matthew R.
    JOURNAL OF THORACIC DISEASE, 2021, 13 (12) : 6827 - +
  • [9] A prospective trial of CT-guided percutaneous microwave ablation for lung tumors
    Reisenauer, Janani S.
    Eiken, Patrick W.
    Callstrom, Matthew R.
    Johnson, Geoffrey B.
    Pierson, Karlyn
    Lechtenberg, Bettie
    Blackmon, Shanda H.
    JOURNAL OF THORACIC DISEASE, 2022, : 939 - 951
  • [10] CT-Guided Microwave Ablation of Liver Tumors in Anatomically Challenging Locations
    Van Dai Vo Chieu
    Werncke, Thomas
    Hensen, Bennet
    Wacker, Frank
    Ringe, Kristina I.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (10) : 1520 - 1529