Stereotactic CT-Guided Percutaneous Microwave Ablation of Liver Tumors With the Use of High-Frequency Jet Ventilation: An Accuracy and Procedural Safety Study

被引:71
|
作者
Engstrand, Jennie [1 ]
Toporek, Grzegorz [2 ]
Harbut, Piotr [1 ]
Jonas, Eduard [1 ]
Nilsson, Henrik [1 ]
Freedman, Jacob [1 ]
机构
[1] Danderyd Hosp AB, Danderyd Hosp, Dept Clin Sci, Karolinska Inst, SE-18288 Stockholm, Sweden
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
关键词
accuracy; interventional radiology; liver; microwave ablation; stereotaxy; RADIOFREQUENCY ABLATION; HEPATIC-TUMORS; HEPATOCELLULAR-CARCINOMA; NAVIGATION SYSTEM; THERMAL ABLATION; GUIDANCE; PHANTOM; BIOPSY; THERMOABLATION; FEASIBILITY;
D O I
10.2214/AJR.15.15803
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS. Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS. Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [+/- SD] lesion diameter, 14.9 +/- 5.9 mm; mean lesion location depth, 87.5 +/- 27.3 mm). The antennae were placed with a mean lateral error of 4.0 +/- 2.5 mm, a depth error of 3.4 +/- 3.2 mm, and a total error of 5.8 +/- 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 +/- 556.5 mGy x cm, but medical personnel were not exposed to irradiation. CONCLUSION. Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the -needle. Therefore, it is technically feasible and applicable for safe treatments.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [31] Hemobilia after CT-guided radiofrequency ablation of liver tumors: frequency, risk factors, and clinical significance
    Hsieh, Mei-Fang
    Chen, Chia-Bang
    Chen, Yao-Li
    Chou, Chen-Te
    ABDOMINAL RADIOLOGY, 2019, 44 (01) : 337 - 345
  • [32] Evaluation of a New CT-Guided Robotic System for Percutaneous Needle Insertion for Thermal Ablation of Liver Tumors: A Prospective Pilot Study
    de Baere, Thierry
    Roux, Charles
    Deschamps, Frederic
    Tselikas, Lambros
    Guiu, Boris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (11) : 1701 - 1709
  • [33] Stereotactic Image-Guided Microwave Ablation for Malignant Liver Tumors-A Multivariable Accuracy and Efficacy Analysis
    Tinguely, Pascale
    Frehner, Lorenz
    Lachenmayer, Anja
    Banz, Vanessa
    Weber, Stefan
    Candinas, Daniel
    Maurer, Martin H.
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [34] Enhanced recovery after surgery for percutaneous CT-guided microwave ablation of lung tumors: A single-center retrospective cohort study
    Peng, Huajian
    Wang, Meijing
    Lu, Shuyu
    Liu, Jun
    Zhang, Yanan
    Fu, Zongwang
    Li, Changqian
    Huang, Yihua
    Guo, Jianji
    Xu, Zhanyu
    Yang, Nuo
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (02) : 651 - 657
  • [35] CT-Guided Microwave Ablation of 45 Renal Tumors: Analysis of Procedure Complexity Utilizing a Percutaneous Renal Ablation Complexity Scoring System
    Mansilla, Alberto V.
    Bivins, Eugene E., Jr.
    Contreras, Francisco
    Hernandez, Manuel A.
    Kohler, Nathan
    Pepe, Julie W.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (02) : 222 - 229
  • [36] High-frequency jet ventilation for minimizing breathing-related liver motion during percutaneous radiofrequency ablation of multiple hepatic tumours
    Biro, P.
    Spahn, D. R.
    Pfammatter, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (05) : 650 - 653
  • [37] Initiation of a High-Frequency Jet Ventilation Strategy for Catheter Ablation for Atrial Fibrillation Safety and Outcomes Data
    Sivasambu, Bhradeev
    Hakim, Joe B.
    Barodka, Viachaslau
    Chrispin, Jonathan
    Berger, Ronald D.
    Ashikaga, Hiroshi
    Ciuffo, Luisa
    Tao, Susumu
    Calkins, Hugh
    Marine, Joseph E.
    Trayanova, Natalia
    Spragg, David D.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (12) : 1519 - 1525
  • [38] Author Correction: Feasibility, safety and accuracy of a CT-guided robotic assistance for percutaneous needle placement in a swine liver model
    Boris Guiu
    Thierry De Baère
    Guillaume Noel
    Maxime Ronot
    Scientific Reports, 11
  • [39] Use of high-frequency jet ventilation for respiratory immobilization during coronary artery CT angiography
    Mandel, Jeff E.
    Perry, Ivan
    Boonn, William W.
    Litt, Harold
    JOURNAL OF CLINICAL ANESTHESIA, 2009, 21 (08) : 599 - 601
  • [40] Editorial Comment: Leveling the Playing Field in Percutaneous Cryoablation of Lung Tumors Using High-Frequency Jet Ventilation
    Keung, Jonathan J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (04)