Stereotactic CT-Guided Percutaneous Microwave Ablation of Liver Tumors With the Use of High-Frequency Jet Ventilation: An Accuracy and Procedural Safety Study

被引:71
|
作者
Engstrand, Jennie [1 ]
Toporek, Grzegorz [2 ]
Harbut, Piotr [1 ]
Jonas, Eduard [1 ]
Nilsson, Henrik [1 ]
Freedman, Jacob [1 ]
机构
[1] Danderyd Hosp AB, Danderyd Hosp, Dept Clin Sci, Karolinska Inst, SE-18288 Stockholm, Sweden
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
关键词
accuracy; interventional radiology; liver; microwave ablation; stereotaxy; RADIOFREQUENCY ABLATION; HEPATIC-TUMORS; HEPATOCELLULAR-CARCINOMA; NAVIGATION SYSTEM; THERMAL ABLATION; GUIDANCE; PHANTOM; BIOPSY; THERMOABLATION; FEASIBILITY;
D O I
10.2214/AJR.15.15803
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS. Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS. Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [+/- SD] lesion diameter, 14.9 +/- 5.9 mm; mean lesion location depth, 87.5 +/- 27.3 mm). The antennae were placed with a mean lateral error of 4.0 +/- 2.5 mm, a depth error of 3.4 +/- 3.2 mm, and a total error of 5.8 +/- 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 +/- 556.5 mGy x cm, but medical personnel were not exposed to irradiation. CONCLUSION. Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the -needle. Therefore, it is technically feasible and applicable for safe treatments.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [41] Percutaneous CT-Guided High-Dose Brachytherapy (CT-HDRBT) Ablation of Primary and Metastatic Lung Tumors in Nonsurgical Candidates
    Collettini, F.
    Schnapauff, D.
    Poellinger, A.
    Denecke, T.
    Banzer, J.
    Golenia, M. J.
    Wust, P.
    Gebauer, B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (04): : 316 - 323
  • [42] Electromagnetic navigation system combined with High-Frequency-Jet-Ventilation for CT-guided hepatic ablation of small US-Undetectable and difficult to access lesions
    Volpi, Stephanie
    Tsoumakidou, Georgia
    Loriaud, Amelie
    Hocquelet, Arnaud
    Duran, Rafael
    Denys, Alban
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (01) : 1051 - 1057
  • [43] Unresectable Colorectal Liver Metastases: Percutaneous Ablation Using CT-Guided High-Dose-Rate Brachytherapy (CT-HDBRT)
    Collettini, F.
    Lutter, A.
    Schnapauff, D.
    Hildebrandt, B.
    Puhl, G.
    Denecke, T.
    Wust, P.
    Gebauer, B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 606 - 612
  • [44] Retrospective cohort study on the correlation analysis among peri-procedural factors, complications, and local tumor progression of lung tumors treated with CT-guided microwave ablation
    Zhu, Linring
    Huang, Jiaxi
    Jin, Chunhui
    Zhou, Acheng
    Chen, Ying
    Zhang, Baonan
    Venuta, Federico
    Pua, Bradley B.
    Shen, Yehua
    JOURNAL OF THORACIC DISEASE, 2023, 15 (12) : 6915 - 6927
  • [45] A safety, feasibility and accuracy study of laparoscopic computer-assisted navigated microwave ablation of liver tumors
    Tinguely, Pascale
    Ribes, Delphine
    Freedman, Jacob
    Karlgren, Silja
    Matteo, Fusagila
    Peterhans, Matthias
    Weber, Stefan
    Candinas, Daniel
    Nilsson, Henrik
    HEPATOLOGY, 2014, 60 : 436A - 436A
  • [46] Assessing ablation margins of FDG-avid liver tumors during PET/CT-guided thermal ablation procedures: a retrospective study
    Casadaban, Leigh C.
    Catalano, Paul J.
    Lee, Leslie K.
    Hyun, Hyewon
    Tuncali, Kemal
    Gerbaudo, Victor H.
    Shyn, Paul B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (09) : 2914 - 2924
  • [47] Assessing ablation margins of FDG-avid liver tumors during PET/CT-guided thermal ablation procedures: a retrospective study
    Leigh C. Casadaban
    Paul J. Catalano
    Leslie K. Lee
    Hyewon Hyun
    Kemal Tuncali
    Victor H. Gerbaudo
    Paul B. Shyn
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 2914 - 2924
  • [48] Size does not matter: Use of peripheral temperature monitoring in laparoscopic-assisted and CT-guided percutaneous radiofrequency ablation of renal tumors
    Wingo, Marshall S.
    Carey, Robert
    Kurzer, Eliecer
    Siddiq, Farjaad M.
    Lopez-Pujals, Alvin
    Leveillee, Raymond J.
    JOURNAL OF UROLOGY, 2007, 177 (04): : 365 - 365
  • [49] Navigated Percutaneous Lung Ablation under High-Frequency Jet Ventilation of a Metastasis from a Wilms' Tumour: A Paediatric Case Report
    Freedman, Jacob
    Harbut, Piotr
    CASE REPORTS IN ONCOLOGY, 2016, 9 (02): : 400 - 404
  • [50] Size does not matter: Use of peripheral temperature monitoring in laparoscopic-assisted and CT-guided percutaneous radiofrequency ablation of renal tumors
    Wingo, Marshall
    Leveillee, Raymond
    JOURNAL OF ENDOUROLOGY, 2007, 21 : A26 - A26