On-line cleaning technique for mitigation of biofouling in heat exchangers: A case study of a hydroelectric power plant in Brazil

被引:24
|
作者
Frota, M. N. [1 ]
Ticona, E. M. [1 ]
Neves, A. V. [1 ]
Marques, R. P. [3 ]
Braga, S. L. [1 ,2 ]
Valente, G. [4 ]
机构
[1] Pontificia Univ Catolica Rio de Janeiro, Postgrad Metrol Programme, BR-22453900 Rio De Janeiro, RJ, Brazil
[2] Pontificia Univ Catolica Rio de Janeiro, Dept Mech Engn, BR-22453900 Rio De Janeiro, RJ, Brazil
[3] CEFET RJ, Dept Mech Engn, Ctr Fed Educ, BR-20271110 Rio De Janeiro, Brazil
[4] Light Energia SA, BR-20080002 Rio De Janeiro, RJ, Brazil
关键词
Biofouling mitigation; On-line cleaning technique; Plate heat exchangers;
D O I
10.1016/j.expthermflusci.2013.12.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental methodology was developed to assess an on-line cleaning technique to mitigate biofouling in plate heat exchangers. The exchangers are used in the cooling system of the journal bearings of hydro-generators of a power plant. The cleaning technology tested consisted of a non-intrusive electronic device wrapped around the water cooling piping that generated an electric field to inhibit the growth of micro-organisms on the heat transfer surfaces. Limnology studies explained the phenomenon of biofouling formation caused by limnophilous microorganisms present in the deepest parts of the reservoir manage to survive in hostile environments under anoxic conditions. Two criteria were adopted to assess the performance of the antifouling technology: a hydrodynamic criterion based on Kakac's pressure drop equation for plate heat exchangers and a thermal criterion (index of fouling) that takes into account the heat transfer effectiveness under the clean and fouled conditions of operation. The position of the antifouling device produced better results when installed in the primary cooling circuit. For the conditions studied, the cleaning technique mitigated biofouling but did not eliminate it completely. Excitation of the flow by an electric field diminishes the pressure drop and the index of fouling when compared to the unexcited flow condition. Control and reduction of the fouling thermal resistance is highly desired as it drastically lessens mechanical pumping costs and increases heat transfer performance. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:197 / 206
页数:10
相关论文
共 50 条
  • [1] The Mitigation Potential of Buffer Strips for Reservoir Sediment Yields: The Itumbiara Hydroelectric Power Plant in Brazil
    Luz, Marta P.
    Beevers, Lindsay C.
    Cuthbertson, Alan J. S.
    Medero, Gabriela M.
    Dias, Viviane S.
    Nascimento, Diego T. F.
    [J]. WATER, 2016, 8 (11)
  • [2] Study of the activity of quaternary ammonium compounds in the mitigation of biofouling in heat exchangers-condensers cooled by seawater
    Trueba, Alfredo
    Otero, Felix M.
    Gonzalez, Jose A.
    Vega, Luis M.
    Garcia, Sergio
    [J]. BIOFOULING, 2013, 29 (09) : 1139 - 1151
  • [3] Symbolic Losses and the People Affected By the Construction of Dams: the Case Study of the Estreito Hydroelectric Power Plant, Brazil
    Assuncao Milhomem Ferreira, Dallyla Tais
    Marques, Elineide Eugenio
    Franco Buenafuente, Sandra Maria
    Barbosa e Souza, Lucas
    Grison, Marcelo da Gama
    Taveira de Lima, Adila Maria
    [J]. DESENVOLVIMENTO E MEIO AMBIENTE, 2014, 30 : 73 - 87
  • [4] Economic Assessment of Solar Hydroelectric Hybrid Power Plant a Real Case Study
    Tuna, M. Cihat
    Aytac, Ayca
    [J]. POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2024, 33 (01): : 415 - 423
  • [5] Feasibility Assessment of Hydroelectric Power Plant in Ungauged River Basin: A Case Study
    M. Cihat Tuna
    [J]. Arabian Journal for Science and Engineering, 2013, 38 : 1359 - 1367
  • [6] Feasibility Assessment of Hydroelectric Power Plant in Ungauged River Basin: A Case Study
    Tuna, M. Cihat
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2013, 38 (06) : 1359 - 1367
  • [7] A CASE-STUDY ON MAINTENANCE POLICY FOR TRANSFER LINE HEAT-EXCHANGERS
    MUKHOPADHYAY, SK
    JOHRI, NK
    [J]. MAINTENANCE MANAGEMENT INTERNATIONAL, 1985, 5 (03): : 201 - 207
  • [8] Comparison of power plant steam condenser heat transfer models for on-line condition monitoring
    Saari, Jussi
    Kaikko, Juha
    Vakkilainen, Esa
    Savolainen, Samuli
    [J]. APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 37 - 47
  • [9] Failures in heat exchangers due to corrosion - (A case study on a chemical fertilizer plant)
    Rassoul, SA
    El-Bahloul, AM
    Mossaad, NB
    [J]. CASE HISTORIES ON INTEGRITY AND FAILURES IN INDUSTRY, 1999, : 631 - 640
  • [10] Performance analysis of heat exchangers of an existing naphtha hydrotreating plant: A case study
    Al-Hadhrami, Luai M.
    Ahmad, Aftab
    Al-Qahtani, Abdullah
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 1029 - 1033