Comparison of power plant steam condenser heat transfer models for on-line condition monitoring

被引:28
|
作者
Saari, Jussi [1 ]
Kaikko, Juha [1 ]
Vakkilainen, Esa [1 ]
Savolainen, Samuli [2 ]
机构
[1] Lappeenranta Univ Technol, FI-53851 Lappeenranta, Finland
[2] Fortum Power & Heat Oy, FI-00048 Fortum, Finland
关键词
Heat exchanger; Condenser; Steam surface condenser; Fouling; SURFACE CONDENSATION; PERFORMANCE; FLOW;
D O I
10.1016/j.applthermaleng.2013.09.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper heat transfer models for large power plant condenser were examined. The goal was to develop a model capable of predicting not only the condenser pressure but the overall heat transfer coefficient. Such a model can be used for condenser condition monitoring. The results of a two-dimensional (2-D) condenser heat transfer model and single-point, zero-dimensional (0-D) model are presented together with the results from Heat Exchanger Institute (HEI) standards curves. Both 0-D and 2-D models can account for the effects of steam-side pressure drop and in a simplified manner also some effects of tube bundle geometry. For all models an experimental correction as a function of cooling water temperature was implemented to improve their accuracy. The results are presented in comparison with the measured plant data for three different tube bundle geometries, with and without the experimental correction factor. The 2-D model proved to be the most consistently accurate of the models both without the correction, and at varying steam and coolant flow with the correction applied. The results indicate significant local variation of pressure drop related effects, which the 0-D model failed to accurately predict particularly in cases of close temperature approach. In predicting the heat transfer coefficient the HEI model was the least accurate, significantly overestimating the impact of coolant flow rate change, and failing to match the measurements even with a correction applied. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:37 / 47
页数:11
相关论文
共 50 条
  • [1] MONITORING OF HEAT-TRANSFER IN A STEAM CONDENSER
    REPIC, V
    TUMA, M
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 1994, 40 (5-6): : 201 - 209
  • [2] On-line condition monitoring of power transformers
    Tenbohlen, S
    Figel, F
    [J]. 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 2211 - 2216
  • [3] On-Line Condition Monitoring and Aging Management System for Nuclear Power Plant Cables
    McConkey, J. Bryan
    Dungan, Nathan A.
    Ferree, Codi R.
    Ellis, Patrick N.
    Connatser, Elijah B.
    [J]. 2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 252 - 255
  • [4] Numerical simulation of heat transfer performance of an air-cooled steam condenser in a thermal power plant
    Xiufeng Gao
    Chengwei Zhang
    Jinjia Wei
    Bo Yu
    [J]. Heat and Mass Transfer, 2009, 45 : 1423 - 1433
  • [5] Numerical simulation of heat transfer performance of an air-cooled steam condenser in a thermal power plant
    Gao, Xiufeng
    Zhang, Chengwei
    Wei, Jinjia
    Yu, Bo
    [J]. HEAT AND MASS TRANSFER, 2009, 45 (11) : 1423 - 1433
  • [6] Condenser Optimization in Steam Power Plant
    Bekdemmir, Sukru
    Ozturk, Recep
    Yumurtac, Zehra
    [J]. JOURNAL OF THERMAL SCIENCE, 2003, 12 (02) : 176 - +
  • [7] Condenser optimization in steam power plant
    Şükrü Bekdemir
    Recep Öztürk
    Zehra Yumurtac
    [J]. Journal of Thermal Science, 2003, 12 : 176 - 178
  • [8] Condenser Optimization in Steam Power Plant
    SükrüBekdemir
    Recepztürk
    ZehraYumurtac
    [J]. Journal of Thermal Science, 2003, (02) : 176 - 178
  • [9] On-line Condition Monitoring of Power Transformers A Case History
    de Pablo, Alfonso
    Ferguson, Walter
    Mudryk, Anatoliy
    Golovan, Dmytro
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 285 - 288
  • [10] On-line condition monitoring and diagnostics of power distribution equipment
    Livshitz, A
    Chudnovsky, BH
    Bukengolts, B
    [J]. 2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 646 - 653