Performance analysis of heat exchangers of an existing naphtha hydrotreating plant: A case study

被引:7
|
作者
Al-Hadhrami, Luai M. [1 ]
Ahmad, Aftab [1 ]
Al-Qahtani, Abdullah [2 ]
机构
[1] King Fahd Univ Petr & Minerals, Res Inst, Engn Res Ctr, Dhahran 31261, Saudi Arabia
[2] Saudi Aramco, Consulting Serv Dept, Dhahran 31311, Saudi Arabia
关键词
Twisted tube; Plain tube; Heat exchanger; Heat transfer; Fouling resistance; Naphtha; Heat transfer coefficient;
D O I
10.1016/j.applthermaleng.2010.01.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the performance evaluation of heat exchangers of an existing naphtha hydrotreating (NHT) plant. Originally, the NHT plant consisted of six plain tube heat exchangers connected in series. During plant revamps operation, three plain tubes were replaced with the three twisted tube heat exchangers. In this study, the heat exchangers data were collected from the plant before and after installation of the three twisted tube heat exchangers. The data were then analyzed to see the effects of the twisted tube configuration on fouling of heat exchangers and heat transfer. The analysis of the data showed that the twisted tube heat exchangers caused reduction in fouling resistance of tubes and increased the heat transfer. Also, the replacement of the three shells and tube type heat exchangers by the twisted tubes resulted in an increase of feed flow rate by about 7.85%. An economic analysis showed that the simple payback period for the twisted tube heat exchangers is 2.12 years. It can be concluded that considerable benefits in terms of energy and cost savings can be realized through the application of this innovative twisted tube heat exchanger technology in existing or new chemical plants. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1029 / 1033
页数:5
相关论文
共 50 条
  • [1] Improving performance of existing heat exchangers - Case studies
    Gibbard, IJ
    [J]. ADVANCES IN INDUSTRIAL HEAT TRANSFER, 1996, : 57 - 63
  • [2] Performance analysis of cation and anion exchangers in water treatment plant: an industrial case study
    Ramzan, Naveed
    Feroze, Nadeem
    Kazmi, Mohsin
    Ashraf, Muhammad Arsalan
    Hasan, Sajid
    [J]. POLISH JOURNAL OF CHEMICAL TECHNOLOGY, 2012, 14 (02) : 35 - 41
  • [3] PERFORMANCE OF REFRIGERATING PLANT WITH EFFICIENT HEAT EXCHANGERS
    Zakirov, S. G.
    Karimov, K. F.
    Azizov, D. Kh.
    Maslov, A. V.
    Nurmatov, T. B.
    [J]. CHEMICAL AND PETROLEUM ENGINEERING, 2008, 44 (3-4) : 198 - 201
  • [4] Performance Evaluation of Heat Exchangers in a Polyethylene Plant
    Lebele-Alawa, Barinaadaa Thaddeus
    Ohia, Innocent Okpara
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING AND TECHNOLOGY INNOVATION, 2013, 3 (01) : 49 - 57
  • [5] Failures in heat exchangers due to corrosion - (A case study on a chemical fertilizer plant)
    Rassoul, SA
    El-Bahloul, AM
    Mossaad, NB
    [J]. CASE HISTORIES ON INTEGRITY AND FAILURES IN INDUSTRY, 1999, : 631 - 640
  • [7] Performance analysis of short helical borehole heat exchangers via integrated modelling of a borefield and a heat pump: A case study
    Zarrella, Angelo
    Capozza, Antonio
    De Carli, Michele
    [J]. APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 36 - 47
  • [8] Performance analysis of an evaporation process of plate heat exchangers installed in a Kalina power plant
    Mergner, Hanna
    Schaber, Karlheinz
    [J]. ENERGY, 2018, 145 : 105 - 115
  • [9] Vibration Analysis of Heat Exchangers of a Nitric Acid Plant
    Soljic, I.
    Matijasevic, Lj.
    Dejanovic, I.
    [J]. CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2009, 23 (03) : 287 - 294
  • [10] Performance based NDE program for balance of plant heat exchangers
    Krzywosz, K
    Cagle, L
    [J]. NDE IN THE NUCLEAR AND PRESSURE VESSEL INDUSTRIES, 1997, : 143 - 146