Performance analysis of cation and anion exchangers in water treatment plant: an industrial case study

被引:5
|
作者
Ramzan, Naveed [1 ]
Feroze, Nadeem [1 ]
Kazmi, Mohsin [1 ]
Ashraf, Muhammad Arsalan [2 ]
Hasan, Sajid [2 ]
机构
[1] Univ Engn & Technol Lahore, Dept Chem Engn, Lahore, Pakistan
[2] Dawood Hercules Chem Ltd, Lahore, Pakistan
关键词
breakthrough curves; degree of column utilization; ion exchange; water treatment; ION-EXCHANGE;
D O I
10.2478/v10026-012-0068-3
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Performance of cation and anion exchangers was evaluated by carrying out breakthrough analyses of pH, conductivity, free mineral acid (FMA) and various dissolved solids for an industrial water treatment plant of 700 gpm capacity. The breakthrough curves showed no leakage of calcium, magnesium and chloride throughout the operating period of the train, however, they indicated the early leakage of sodium, potassium, sulphate and silica. The operating/breakthrough capacity, total capacity and degree of column utilization were determined. The column utilization was found to be 67.85%, 38.93% and 16.78% against the design values of 90%, 85% and 85% for cation, primary and secondary anion exchangers respectively. The operating time of the water treatment train was significantly increased by achieving adequate capacity utilization of secondary anion exchanger. The low capacity utilization of secondary anion resin due to early silica slippage, has been discussed in the paper.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Performance analysis of heat exchangers of an existing naphtha hydrotreating plant: A case study
    Al-Hadhrami, Luai M.
    Ahmad, Aftab
    Al-Qahtani, Abdullah
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 1029 - 1033
  • [2] ANION EXCHANGERS FUNCTIONAL INSPECTION OF WATER DEMINERALIZATION PLANT
    MROZEK, J
    [J]. PRZEMYSL CHEMICZNY, 1969, 48 (10): : 588 - &
  • [3] Performance of small water treatment plants: The case study of Mutshedzi Water Treatment Plant
    Makungo, R.
    Odiyo, J. O.
    Tshidzumba, N.
    [J]. PHYSICS AND CHEMISTRY OF THE EARTH, 2011, 36 (14-15) : 1151 - 1158
  • [4] Practical performance analysis of an industrial-scale ultrafiltration membrane water treatment plant
    Chew, Chun Ming
    Aroua, M. K.
    Hussain, M. A.
    Ismail, W. M. Z. Wan
    [J]. Journal of the Taiwan Institute of Chemical Engineers, 2015, 46 : 132 - 139
  • [5] Weakly acid cation exchangers using in water treatment technology
    Vysotskij, S.P.
    Poddubnaya, E.V.
    [J]. Khimiya i Tekhnologiya Vody, 2002, 24 (02): : 167 - 173
  • [6] Optimization of Maintenance Management of Industrial Water Heat Exchangers and Water Treatment
    Hayashi, Kazuhiro
    Tateno, Shigeyuki
    Matsuyama, Hisayoshi
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2019, 52 (01) : 121 - 129
  • [7] Modeling and Dependability Analysis of an Industrial Plant: Case Study
    Zennir, Youcef
    Bendib, Riad
    [J]. 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND SYSTEMS MANAGEMENT (IESM), 2015, : 1012 - 1018
  • [8] Industrial wastewater minimization using water pinch analysis: a case study on an old textile plant
    Ujang, Z
    Wong, CL
    Manan, ZA
    [J]. WATER SCIENCE AND TECHNOLOGY, 2002, 46 (11-12) : 77 - 84
  • [9] Organic and inorganic fouling in heat exchangers - Industrial case study: Analysis of fouling state
    Diaz-Bejarano, E.
    Behranvand, E.
    Coletti, F.
    Mozdianfard, M. R.
    Macchietto, S.
    [J]. APPLIED ENERGY, 2017, 206 : 1250 - 1266
  • [10] Organic and Inorganic Fouling in Heat Exchangers: Industrial Case Study Analysis of Fouling Rate
    Diaz-Bejarano, Emilio
    Behranvand, Elaheh
    Coletti, Francesco
    Mozdianfard, Mohammad Reza
    Macchietto, Sandro
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (01) : 228 - 246