Glenohumeral Articular Cartilage Lesions: Prospective Comparison of Non-Contrast Magnetic Resonance Imaging and Findings at Arthroscopy

被引:10
|
作者
Spencer, Brian A. [1 ]
Dolinskas, Carol A. [2 ]
Seymour, Peter A. [3 ]
Thomas, Stephen J. [3 ]
Abboud, Joseph A. [4 ]
机构
[1] Mt Nittany Med Ctr, Dept Orthoped, State Coll, PA 16803 USA
[2] Penn Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[3] Univ Penn, Dept Orthoped, Philadelphia, PA 19104 USA
[4] Rothman Inst, Dept Orthoped, Philadelphia, PA USA
关键词
ROTATOR CUFF TEARS; IMPINGEMENT SYNDROME; MR ARTHROGRAPHY; KNEE; JOINT; CADAVERS; QUANTIFICATION; INSTABILITY; THICKNESS; DIAGNOSIS;
D O I
10.1016/j.arthro.2013.05.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Methods: Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. Results: At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. Conclusions: This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level of Evidence: Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard.
引用
收藏
页码:1466 / 1470
页数:5
相关论文
共 50 条
  • [31] Use magnetic resonance imaging to assess articular cartilage
    Wang, Yuanyuan
    Wluka, Anita
    Jones, Graeme
    Ding, Changhai
    Cicuttini, Flavia M.
    THERAPEUTIC ADVANCES IN MUSCULOSKELETAL DISEASE, 2012, 4 (02) : 77 - 97
  • [32] Magnetic Resonance Imaging of Articular Cartilage within the Knee
    Argentieri, Erin C.
    Burge, Alissa J.
    Potter, Hollis G.
    JOURNAL OF KNEE SURGERY, 2018, 31 (02) : 155 - 165
  • [33] Quantitative magnetic resonance imaging of articular cartilage in osteoarthritis
    Blumenkrantz, Gabrielle
    Majumdar, Sharmila
    EUROPEAN CELLS & MATERIALS, 2007, 13 : 75 - 86
  • [34] Quantitative measurements of articular cartilage by magnetic resonance imaging
    LD Hall
    J Burge
    S Evans
    R Poole
    Arthritis Res Ther, 6 (Suppl 3):
  • [35] Magnetic resonance imaging for articular cartilage: cartilage-bone mismatch
    Staeubli, HU
    Bosshard, C
    Porcellini, P
    Rauschning, W
    CLINICS IN SPORTS MEDICINE, 2002, 21 (03) : 417 - +
  • [36] Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy
    Frédéric E. Lecouvet
    Benjamin Dorzée
    Jean E. Dubuc
    Bruno C. Vande Berg
    Jacques Jamart
    Jacques Malghem
    European Radiology, 2007, 17 : 1763 - 1771
  • [37] Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy
    Lecouvet, Frederic E.
    Dorzee, Benjamin
    Dubuc, Jean E.
    Vande Berg, Bruno C.
    Jamart, Jacques
    Malghem, Jacques
    EUROPEAN RADIOLOGY, 2007, 17 (07) : 1763 - 1771
  • [38] Diagnostic Accuracy of 3.0 Tesla Magnetic Resonance Imaging for the Detection of Articular Cartilage Lesions of the Talus
    Gatlin, Coley C.
    Matheny, Lauren M.
    Ho, Charles P.
    Johnson, Nicholas S.
    Clanton, Thomas O.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (03) : 288 - 292
  • [39] Non-contrast enhanced magnetic resonance imaging for characterization of Fontan associated liver disease
    Langguth, Patrick
    Ravesh, Mona Salehi
    Moritz, Joerg Detlev
    Rinne, Katy
    Harneit, Paul Lennard
    Khodami, Joshua Kian
    Graessner, Joachim
    Uebing, Anselm
    Jansen, Olav
    Both, Marcus
    Hansen, Jan Hinnerk
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 349 : 48 - 54
  • [40] Comparison of Arthroscopic and Magnetic Resonance Imaging Findings in Osteochondral Lesions of the Talus
    Bae, SooHo
    Lee, Hyeon Kyeong
    Lee, Kyunghee
    Lim, Sanghyeok
    Rim, Nae-Jung
    Kim, Jin-Su
    Cho, Jaeho
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (12) : 1058 - 1062