Glenohumeral Articular Cartilage Lesions: Prospective Comparison of Non-Contrast Magnetic Resonance Imaging and Findings at Arthroscopy

被引:10
|
作者
Spencer, Brian A. [1 ]
Dolinskas, Carol A. [2 ]
Seymour, Peter A. [3 ]
Thomas, Stephen J. [3 ]
Abboud, Joseph A. [4 ]
机构
[1] Mt Nittany Med Ctr, Dept Orthoped, State Coll, PA 16803 USA
[2] Penn Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[3] Univ Penn, Dept Orthoped, Philadelphia, PA 19104 USA
[4] Rothman Inst, Dept Orthoped, Philadelphia, PA USA
关键词
ROTATOR CUFF TEARS; IMPINGEMENT SYNDROME; MR ARTHROGRAPHY; KNEE; JOINT; CADAVERS; QUANTIFICATION; INSTABILITY; THICKNESS; DIAGNOSIS;
D O I
10.1016/j.arthro.2013.05.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Methods: Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. Results: At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. Conclusions: This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level of Evidence: Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard.
引用
收藏
页码:1466 / 1470
页数:5
相关论文
共 50 条
  • [41] Evaluation of characteristic non-contrast magnetic resonance lymphangiography findings based on indocyanine green lymphography
    Kageyama, Takashi
    MICROSURGERY, 2022, 42 (03) : 298 - 299
  • [42] Non-contrast MR imaging of the glenohumeral joint. Part II. Glenohumeral instability and labrum tears
    Mahvash Rafii
    Skeletal Radiology, 2004, 33 : 617 - 626
  • [43] Non-contrast MR imaging of the glenohumeral joint. Part II. Glenohumeral instability and labrum tears
    Rafii, M
    SKELETAL RADIOLOGY, 2004, 33 (11) : 617 - 626
  • [44] Moderate value of non-contrast magnetic resonance imaging after non-dislocating shoulder trauma
    Banerjee, Marc
    Mueller-Huebenthal, Jonas
    Grimme, Stefan
    Balke, Maurice
    Bouillon, Bertil
    Lefering, Rolf
    Gossmann, Axel
    Shafizadeh, Sven
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (06) : 1888 - 1895
  • [45] Moderate value of non-contrast magnetic resonance imaging after non-dislocating shoulder trauma
    Marc Banerjee
    Jonas Müller-Hübenthal
    Stefan Grimme
    Maurice Balke
    Bertil Bouillon
    Rolf Lefering
    Axel Goßmann
    Sven Shafizadeh
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 1888 - 1895
  • [46] Quantitative Magnetic Resonance Imaging of the Articular Cartilage of the knee Joint
    Kijowski, Richard
    Chaudhary, Rajeev
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (04) : 649 - +
  • [47] Ultrasound biomicroscopy and magnetic resonance imaging of reconstituted articular cartilage
    Harasiewicz, KA
    Gahunia, HK
    Lemaire, C
    Konyer, NB
    Kim, HKW
    Babyn, PS
    Pritzker, KPH
    Foster, FS
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1149 - 1152
  • [48] Magnetic resonance imaging of articular cartilage - Trauma, degeneration, and repair
    Potter, HG
    Foo, LF
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (04): : 661 - 677
  • [49] Simultaneous Magnetic Resonance Imaging and Consolidation Measurement of Articular Cartilage
    Wellard, Robert Mark
    Ravasio, Jean-Philippe
    Guesne, Samuel
    Bell, Christopher
    Oloyede, Adekunle
    Tevelen, Greg
    Pope, James M.
    Momot, Konstantin I.
    SENSORS, 2014, 14 (05): : 7940 - 7958
  • [50] Visualization of Articular Cartilage Using Magnetic Resonance Imaging Data
    Poh, C. L.
    Sheah, K.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 386 - +