Analysis of plasticizers in PVC medical devices: Performance comparison of eight analytical methods

被引:18
|
作者
Bernard, L. [1 ,2 ]
Bourdeaux, D. [1 ,2 ]
Pereira, B. [3 ]
Azaroual, N. [4 ]
Barthelemy, C. [4 ]
Breysse, C. [5 ]
Chennell, P. [1 ,2 ]
Cueff, R. [2 ]
Dine, T. [4 ]
Eljezi, T. [2 ]
Feutry, F. [4 ]
Genay, S. [4 ]
Kambia, N. [4 ]
Lecoeur, M. [4 ]
Masse, M. [4 ,6 ]
Odou, P. [4 ,6 ]
Radaniel, T. [4 ]
Simon, N. [4 ,6 ]
Vaccher, C. [4 ]
Verlhac, C. [2 ]
Yessad, M. [2 ]
Decaudin, B. [4 ,6 ]
Sautou, V. [1 ,2 ]
机构
[1] CHU Clermont Ferrand, Pole Pharm, Rue Montalembert, F-63003 Clermont Ferrand, France
[2] Univ Auvergne, Clermont Univ, EA BIOSENSS 4676 C, BP 10448, F-63000 Clermont Ferrand, France
[3] CHU Clermont Ferrand, Unite Biostat Delegat Rech Clin & Innovat, F-63000 Clermont Ferrand, France
[4] Univ Lille, Grp Rech Formes Injectables & Technol Associees, GRITA, EA 7365, F-59000 Lille, France
[5] Ctr Ressources Technol 3sInpack, F-63173 Aubiere, France
[6] CHU Lille, Inst Pharm, F-59000 Lille, France
关键词
Analytical methods; Plasticizers; Comparison; Medical devices; QUANTITATIVE ANALYTICAL PROCEDURES; SUPERCRITICAL-FLUID CHROMATOGRAPHY; SFSTP PROPOSAL; GC-MS; VALIDATION; HARMONIZATION; STRATEGIES; MIGRATION; INFUSION; QUANTIFICATION;
D O I
10.1016/j.talanta.2016.10.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the "blind test" carried out on 10 MD samples.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 50 条
  • [41] Performance Comparison of Analytical and Numerical Methods of Elastic Properties of Composite Micromechanics
    Erturk, Alpay Tamer
    Acikgoz, Cagatay
    ADVANCES IN MACHINERY, MATERIALS SCIENCE AND ENGINEERING APPLICATION, 2022, 24 : 10 - 15
  • [42] Comparison of Analytical and Clinical Performance of Three Methods for Detection of Clostridium difficile
    LaSala, P. Rocco
    Svensson, Annika M.
    Mohammad, Amin A.
    Perrotta, Peter L.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2012, 136 (05) : 527 - 531
  • [43] Performance Comparison of Feature Selection Methods for Prediction in Medical Data
    Khalid, Nur Hidayah Mohd
    Ismail, Amelia Ritahani
    Aziz, Normaziah Abdul
    Hussin, Amir Aatieff Amir
    SOFT COMPUTING IN DATA SCIENCE, SCDS 2023, 2023, 1771 : 92 - 106
  • [44] The analytical evaluation threshold for inorganic metal extractables and leachables analysis of medical devices
    Satori, Chad P.
    Christensen, Catherine D.
    Street, Stephanie M.
    Giffin, Mikaelle
    Pohl, Christopher M.
    Christian, Whitney, V
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2024, 154
  • [45] Analytical Ultracentrifugation of Model Nanoparticles: Comparison of Different Analysis Methods
    Mittal, Vikas
    Voelkel, Antje
    Coelfen, Helmut
    MACROMOLECULAR BIOSCIENCE, 2010, 10 (07) : 754 - 762
  • [46] Comparison of three analytical methods for cocaine analysis of illicit powders
    Campanella, L
    Colapicchioni, C
    Tomassetti, M
    Dezzi, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) : 1047 - 1054
  • [47] A COMPARISON OF ANALYTICAL METHODS FOR NITROGEN ANALYSIS IN PLANT-TISSUES
    SIMONNE, EH
    MILLS, HA
    JONES, JB
    SMITTLE, DA
    HUSSEY, CG
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1994, 25 (7-8) : 943 - 954
  • [48] COMPARISON OF ANALYTICAL METHODS FOR RESIDUAL ETHYLENE-OXIDE ANALYSIS
    ROMANO, SJ
    RENNER, JA
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1975, 64 (08) : 1412 - 1417
  • [49] Wear analysis of failed acetabular polyethylene - A Comparison of analytical methods
    Chuter, G. S. J.
    Cloke, D. J.
    Mahomed, A.
    Partington, P. F.
    Green, S. M.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02): : 273 - 279
  • [50] Computational performance of analytical methods for the acoustic modelling of automotive exhaust devices incorporating monoliths
    Denia, F. D.
    Martinez-Casas, J.
    Carballeira, J.
    Nadal, E.
    Fuenmayor, F. J.
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2018, 330 : 995 - 1006