Analysis of plasticizers in PVC medical devices: Performance comparison of eight analytical methods

被引:18
|
作者
Bernard, L. [1 ,2 ]
Bourdeaux, D. [1 ,2 ]
Pereira, B. [3 ]
Azaroual, N. [4 ]
Barthelemy, C. [4 ]
Breysse, C. [5 ]
Chennell, P. [1 ,2 ]
Cueff, R. [2 ]
Dine, T. [4 ]
Eljezi, T. [2 ]
Feutry, F. [4 ]
Genay, S. [4 ]
Kambia, N. [4 ]
Lecoeur, M. [4 ]
Masse, M. [4 ,6 ]
Odou, P. [4 ,6 ]
Radaniel, T. [4 ]
Simon, N. [4 ,6 ]
Vaccher, C. [4 ]
Verlhac, C. [2 ]
Yessad, M. [2 ]
Decaudin, B. [4 ,6 ]
Sautou, V. [1 ,2 ]
机构
[1] CHU Clermont Ferrand, Pole Pharm, Rue Montalembert, F-63003 Clermont Ferrand, France
[2] Univ Auvergne, Clermont Univ, EA BIOSENSS 4676 C, BP 10448, F-63000 Clermont Ferrand, France
[3] CHU Clermont Ferrand, Unite Biostat Delegat Rech Clin & Innovat, F-63000 Clermont Ferrand, France
[4] Univ Lille, Grp Rech Formes Injectables & Technol Associees, GRITA, EA 7365, F-59000 Lille, France
[5] Ctr Ressources Technol 3sInpack, F-63173 Aubiere, France
[6] CHU Lille, Inst Pharm, F-59000 Lille, France
关键词
Analytical methods; Plasticizers; Comparison; Medical devices; QUANTITATIVE ANALYTICAL PROCEDURES; SUPERCRITICAL-FLUID CHROMATOGRAPHY; SFSTP PROPOSAL; GC-MS; VALIDATION; HARMONIZATION; STRATEGIES; MIGRATION; INFUSION; QUANTIFICATION;
D O I
10.1016/j.talanta.2016.10.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the "blind test" carried out on 10 MD samples.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 50 条
  • [21] A comparison study of analytical performance of chromium speciation methods
    Jozsef, Posta
    David, Nagy
    Sandor, Kapitany
    Aron, Beni
    MICROCHEMICAL JOURNAL, 2019, 149
  • [22] Analysis of pure copper – a comparison of analytical methods
    Britta Lange
    Sebastian Recknagel
    Michael Czerwensky
    Ralf Matschat
    Matthias Michaelis
    Burkhard Peplinski
    Ulrich Panne
    Microchimica Acta, 2008, 160 : 97 - 107
  • [23] Comparison of numerical and analytical methods of analysis of tunnels
    Elarabi, H.
    Mustafa, A.
    GEOTECHNICAL ASPECTS OF UNDERGROUND CONSTRUCTION IN SOFT GROUND, 2014, : 225 - 231
  • [24] Analysis of pure copper - a comparison of analytical methods
    Lange, Britta
    Recknagel, Sebastian
    Czerwensky, Michael
    Matschat, Ralf
    Michaelis, Matthias
    Peplinski, Burkhard
    Panne, Ulrich
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 97 - 107
  • [25] Modelling the performance of upper room ultraviolet germicidal irradiation devices in ventilated rooms: Comparison of analytical and CFD methods
    Noakes, CJ
    Beggs, CB
    Sleigh, PA
    INDOOR AND BUILT ENVIRONMENT, 2004, 13 (06) : 477 - 488
  • [26] Analytical methods for the determination of DEHP plasticizer alternatives present in medical devices: A review
    Bernard, L.
    Decaudin, B.
    Lecoeur, M.
    Richard, D.
    Bourdeaux, D.
    Cueff, R.
    Sautou, V.
    TALANTA, 2014, 129 : 39 - 54
  • [27] Comparison of the analytical performance of filament and Curie-point pyrolysis devices
    Stankiewicz, BA
    van Bergen, PF
    Smith, MB
    Carter, JF
    Briggs, DEG
    Evershed, RP
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1998, 45 (02) : 133 - 151
  • [28] A Comparison of Decolorization Methods Performance for Medical Color Images
    Vertan, Constantin
    Voicea, Georgiana
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [29] Performance comparison of optimization methods for medical image registration
    Pan, Meisen
    Jiang, Jianjun
    Zhang, Fen
    Fang, Xia
    Journal of Fiber Bioengineering and Informatics, 2014, 7 (04): : 507 - 516
  • [30] Comparison of Two Analytical Methods for the Analysis of Methylmercury in Fish
    Wang, Zhongwen
    Forsyth, Don
    Belisle, Stephane
    Beraldin, Franca
    Sparling, Melissa
    Trudelle, Renee-Anne
    Lapointe, Pascal
    Bellon-Gagnon, Pascale
    FOOD ANALYTICAL METHODS, 2013, 6 (01) : 157 - 163