Analysis of plasticizers in PVC medical devices: Performance comparison of eight analytical methods

被引:18
|
作者
Bernard, L. [1 ,2 ]
Bourdeaux, D. [1 ,2 ]
Pereira, B. [3 ]
Azaroual, N. [4 ]
Barthelemy, C. [4 ]
Breysse, C. [5 ]
Chennell, P. [1 ,2 ]
Cueff, R. [2 ]
Dine, T. [4 ]
Eljezi, T. [2 ]
Feutry, F. [4 ]
Genay, S. [4 ]
Kambia, N. [4 ]
Lecoeur, M. [4 ]
Masse, M. [4 ,6 ]
Odou, P. [4 ,6 ]
Radaniel, T. [4 ]
Simon, N. [4 ,6 ]
Vaccher, C. [4 ]
Verlhac, C. [2 ]
Yessad, M. [2 ]
Decaudin, B. [4 ,6 ]
Sautou, V. [1 ,2 ]
机构
[1] CHU Clermont Ferrand, Pole Pharm, Rue Montalembert, F-63003 Clermont Ferrand, France
[2] Univ Auvergne, Clermont Univ, EA BIOSENSS 4676 C, BP 10448, F-63000 Clermont Ferrand, France
[3] CHU Clermont Ferrand, Unite Biostat Delegat Rech Clin & Innovat, F-63000 Clermont Ferrand, France
[4] Univ Lille, Grp Rech Formes Injectables & Technol Associees, GRITA, EA 7365, F-59000 Lille, France
[5] Ctr Ressources Technol 3sInpack, F-63173 Aubiere, France
[6] CHU Lille, Inst Pharm, F-59000 Lille, France
关键词
Analytical methods; Plasticizers; Comparison; Medical devices; QUANTITATIVE ANALYTICAL PROCEDURES; SUPERCRITICAL-FLUID CHROMATOGRAPHY; SFSTP PROPOSAL; GC-MS; VALIDATION; HARMONIZATION; STRATEGIES; MIGRATION; INFUSION; QUANTIFICATION;
D O I
10.1016/j.talanta.2016.10.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the "blind test" carried out on 10 MD samples.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 50 条
  • [31] Comparison of Two Analytical Methods for the Analysis of Methylmercury in Fish
    Zhongwen Wang
    Don Forsyth
    Stephane Belisle
    Franca Beraldin
    Melissa Sparling
    Renee-Anne Trudelle
    Pascal Lapointe
    Pascale Bellon-Gagnon
    Food Analytical Methods, 2013, 6 : 157 - 163
  • [32] STEP LADDER FAILURE ANALYSIS, A COMPARISON OF ANALYTICAL METHODS
    Kenner, Matthew T.
    Stevenson, Michael E.
    Knox, Erick H.
    Van Bree, Michael P.
    Wilkinson, John A.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 9, 2012, : 397 - 405
  • [33] GAS ANALYTICAL METHODS OF THERMAL-ANALYSIS IN COMPARISON
    KAISERSBERGER, E
    THERMOCHIMICA ACTA, 1979, 29 (02) : 215 - 220
  • [34] Analysis and comparison of 2D fingerprints: Insights into database screening performance using eight fingerprint methods
    Duan, Jianxin
    Dixon, Steven L.
    Lowrie, Jeffrey F.
    Sherman, Woody
    JOURNAL OF MOLECULAR GRAPHICS & MODELLING, 2010, 29 (02): : 157 - 170
  • [35] Analysis and comparison of 2D fingerprints: insights into database screening performance using eight fingerprint methods
    J Duan
    M Sastry
    SL Dixon
    JF Lowrie
    W Sherman
    Journal of Cheminformatics, 3 (Suppl 1)
  • [36] Analysis of plasticizers in poly(vinyl chloride) medical devices for infusion and artificial nutrition: comparison and optimization of the extraction procedures, a pre-migration test step
    Lise Bernard
    Régis Cueff
    Daniel Bourdeaux
    Colette Breysse
    Valérie Sautou
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1651 - 1659
  • [37] Analysis of plasticizers in poly(vinyl chloride) medical devices for infusion and artificial nutrition: comparison and optimization of the extraction procedures, a pre-migration test step
    Bernard, Lise
    Cueff, Regis
    Bourdeaux, Daniel
    Breysse, Colette
    Sautou, Valerie
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (06) : 1651 - 1659
  • [38] New SPE-LC-MS/MS method for the simultaneous determination in urine of 22 metabolites of DEHP and alternative plasticizers from PVC medical devices
    Pinguet, Jeremy
    Kerckhove, Nicolas
    Eljezi, Teuta
    Lambert, Celine
    Moreau, Emmanuel
    Bernard, Lise
    Boeuf, Benoit
    Decaudin, Bertrand
    Genay, Stephanie
    Masse, Morgane
    Storme, Laurent
    Sautou, Valerie
    Richard, Damien
    TALANTA, 2019, 198 : 377 - 389
  • [39] A Comparative Analysis of the Performance of PVC Film Aging by Ultraviolet and Thermal Methods
    Li, Chen
    Xiao, ShengLing
    ADVANCED RESEARCH ON MATERIAL ENGINEERING, CHEMISTRY, BIOINFORMATICS III, 2014, 830 : 45 - 48
  • [40] ANALYTICAL METHODS AND PERFORMANCE OF THE IMMUNOASSAY METHODS FOR DETERMINATION OF VITAMIN D IN COMPARISON TO MASS SPECTROMETRY
    Babic, Nikolina
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2012, 31 (04) : 333 - 338