A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy

被引:151
|
作者
Nutting, CM
Bedford, JL
Cosgrove, VP
Tait, DM
Dearnaley, DP
Webb, S
机构
[1] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[2] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Acad Dept Radiotherapy, Sutton SM2 5PT, Surrey, England
关键词
oesophageal carcinoma; conformal radiotherapy; intensity-modulated radiotherapy; radiation pneumonitis; dose escalation;
D O I
10.1016/S0167-8140(01)00438-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy. Materials and methods: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities. Results: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9 +/- 4.5 (1 SD) vs. 12.4 +/- 3.9%; P = 0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7 +/- 3.2 vs. 11.0 +/- 2.9 Gy; P = 0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8 +/- 3.3 vs. 12.4 +/- 3.9%; P = 0.6), with reduced mean lung dose (9.5 +/- 2.3 vs 11.0 +/- 2.9 Gy; P = 0.001). Conclusions: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [21] TREATMENT DELIVERY ACCURACY IN INTENSITY-MODULATED CONFORMAL RADIOTHERAPY
    CONVERY, DJ
    ROSENBLOOM, ME
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06): : 979 - 999
  • [22] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [23] Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques
    Nutting, CM
    Rowbottom, CG
    Cosgrove, VP
    Henk, JM
    Dearnaley, DP
    Robinson, MH
    Conway, J
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) : 163 - 172
  • [24] Target coverage in head and neck cancer treated with intensity-modulated radiotherapy: A comparison between conventional and conformal techniques
    Palazzi, Mauro
    Orlandi, Ester
    Pignoli, Emanuele
    Lualdi, Manuela
    Zonca, Giancarlo
    Sangalli, Claudia
    Stucchi, Claudio
    Olmi, Patrizia
    [J]. TUMORI JOURNAL, 2006, 92 (06): : 503 - 510
  • [25] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    [J]. EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [26] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [27] Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy
    Landau, D
    Adams, EJ
    Webb, S
    Ross, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) : 247 - 255
  • [28] A comparison of morbidity following conformal versus intensity-modulated radiotherapy for urinary bladder cancer
    Sondergaard, Jimmi
    Holmberg, Mats
    Jakobsen, Annette Ross
    Agerbaek, Mads
    Muren, Ludvig Paul
    Hoyer, Morten
    [J]. ACTA ONCOLOGICA, 2014, 53 (10) : 1321 - 1328
  • [29] A comparison of conventional, conformal and intensity-modulated coplanar radiotherapy plans for posterior fossa treatment
    Breen, SL
    Kehagioglou, P
    Usher, C
    Plowman, PN
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (921): : 768 - 774
  • [30] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy with Hybrid Intensity-Modulated Radiotherapy Techniques for Treatment of Locally Advanced Lung Cancer
    Suyunmez, Ozge
    Genc, Mine
    Ciftlikli, Ozlem Toykan
    Tuncel, Nina
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (03): : 239 - 245