摘要
The importance of geometric and dosimetric inaccuracies in the delivery of conformal radiotherapy using intensity-modulated x-ray fields is assessed. It is shown that although the incident intensity or fluence profiles may have large gradients, the resulting absorbed dose profile gradients are shallower because of electron transport and photon scatter. This makes the interleaving of dose contributions from the many intensity-modulated fields used less critically dependent on their relative positions and on the accuracy of profile generation. It is found that the expected geometric and dosimetric inaccuracies do not make this technique impracticable provided that good patient fixation and beam delivery can be assured.
引用
收藏
页码:979 / 999
页数:21
相关论文
共 50 条
  • [1] Advances in treatment with intensity-modulated conformal radiotherapy
    Webb, S
    [J]. TUMORI JOURNAL, 1998, 84 (02): : 112 - 126
  • [2] Conformal radiotherapy and intensity-modulated radiotherapy -: Clinical data
    Tubiana, M
    Eschwège, F
    [J]. ACTA ONCOLOGICA, 2000, 39 (05) : 555 - 567
  • [3] Conformal and intensity-modulated radiotherapy for cervical cancer
    Taylor, A.
    Powell, M. E. B.
    [J]. CLINICAL ONCOLOGY, 2008, 20 (06) : 417 - 425
  • [4] A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy
    Nutting, CM
    Bedford, JL
    Cosgrove, VP
    Tait, DM
    Dearnaley, DP
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 157 - 163
  • [5] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121
  • [6] VOLUMETRIC MODULATED ARC THERAPY FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Palma, David
    Vollans, Emily
    James, Kerry
    Nakano, Sandy
    Moiseenko, Vitali
    Shaffer, Richard
    Mckenzie, Michael
    Morris, James
    Otto, Karl
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 996 - 1001
  • [7] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL PROTON RADIOTHERAPY, INTENSITY-MODULATED PROTON THERAPY, AND INTENSITY-MODULATED RADIOTHERAPY FOR TREATMENT OF PEDIATRIC CRANIOPHARYNGIOMAS
    Boehling, Nicholas S.
    Grosshans, David R.
    Bluett, Jaques B.
    Palmer, Matthew T.
    Song, Xiaofei
    Amos, Richard A.
    Sahoo, Narayan
    Meyer, Jeffrey J.
    Mahajan, Anita
    Woo, Shiao Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 643 - 652
  • [8] Treatment of bone and soft tissue tumors of the limbs with conformal radiotherapy and intensity-modulated radiotherapy (IMRT)
    Castilho, Marcus Simoes
    Ferrigno, Robson
    Baraldi, Helena
    Ribeiro dos Santos Novaes, Paulo Eduardo
    [J]. REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2017, 63 (06): : 477 - 480
  • [9] Rectal Radiotherapy - Intensity-modulated Radiotherapy Delivery, Delineation and Doses
    Teoh, S.
    Muirhead, R.
    [J]. CLINICAL ONCOLOGY, 2016, 28 (02) : 93 - 102
  • [10] A COMPARISON OF HELICAL INTENSITY-MODULATED RADIOTHERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D-CONFORMAL RADIATION THERAPY FOR PANCREATIC CANCER
    Poppe, Matthew M.
    Narra, Venkat
    Yue, Ning J.
    Zhou, Jinghao
    Nelson, Carl
    Jabbour, Salma K.
    [J]. MEDICAL DOSIMETRY, 2011, 36 (04) : 351 - 357