Conformal radiotherapy and intensity-modulated radiotherapy -: Clinical data

被引:0
|
作者
Tubiana, M [1 ]
Eschwège, F [1 ]
机构
[1] Inst Gustave Roussy, Villejuif, France
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Conformal radiotherapy (CRT) is based on three hypotheses: (i) a higher rate of local control can improve the survival rate; (ii) dose escalation can increase tumor control: and (iii) CRT allows the delivery of higher doses by decreasing the incidence of late effects. These postulates are nov: supported by several data. Three-dimensional conformal radiotherapy (3D-CRT) has markedly progressed since its introduction two decades ago. However, there are situations for which 3D-CRT cannot produce a satisfactory treatment plan because of complex target volume shapes or the close proximity of sensitive normal tissues. This is why intensity-modulated radiation therapy (IMRT) was introduced. Its aim is to overcome the limitations of 3D-CRT by adding modulators of beam intensity to beam shaping. IMRT can achieve nearly any dose distribution; however. the role of the planner remains crucial. CRT has been investigated mainly for prostate cancers and head and neck cancers. By and large, the clinical data, although still limited, seem to confirm the advantages of this type of radiotherapy. Dose escalation in prostate cancers improves the local control rate without increasing late effects and for this cancer site IMRT appears to be a significant advance over conventional 3D-CRT. In head and neck cancers the clinical data are still scarce but encouraging. CRT should be investigated in breast cancers with the aim of reducing the incidence of late effects. The available data underline the great potential for major progress in 3D-CRT and IMRT. The techniques are still costly and time consuming, nevertheless they merit investigation since their cost should decrease. Efforts should be concentrated on the specification of robust optimization criteria, taking into account clinical and radiobiological data.
引用
收藏
页码:555 / 567
页数:13
相关论文
共 50 条
  • [1] Advances in treatment with intensity-modulated conformal radiotherapy
    Webb, S
    [J]. TUMORI JOURNAL, 1998, 84 (02): : 112 - 126
  • [2] Conformal and intensity-modulated radiotherapy for cervical cancer
    Taylor, A.
    Powell, M. E. B.
    [J]. CLINICAL ONCOLOGY, 2008, 20 (06) : 417 - 425
  • [3] CLINICAL REALIZATION OF 3D CONFORMAL INTENSITY-MODULATED RADIOTHERAPY
    BUTLER, EB
    WOO, SY
    GRANT, W
    NIZIN, PS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (05): : 1547 - 1548
  • [4] Clinical results of retreatment of vertebral bone metastases by stereotactic conformal radiotherapy and intensity-modulated radiotherapy
    Milker-Zabel, S
    Zabel, A
    Thilmann, C
    Schlegel, W
    Wannenmacher, M
    Debus, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (01): : 162 - 167
  • [6] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [7] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    [J]. Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [8] Adjuvant radiotherapy for gallbladder cancer: A dosimetric comparison of conformal radiotherapy and intensity-modulated radiotherapy
    Sun, Xiao-Nan
    Wang, Qi
    Gu, Ben-Xing
    Zhu, Yan-Hong
    Hu, Jian-Bin
    Shi, Guo-Zhi
    Zheng, Shu
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (03) : 397 - 402
  • [9] A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapy
    Nutting, CM
    Bedford, JL
    Cosgrove, VP
    Tait, DM
    Dearnaley, DP
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 157 - 163
  • [10] TREATMENT DELIVERY ACCURACY IN INTENSITY-MODULATED CONFORMAL RADIOTHERAPY
    CONVERY, DJ
    ROSENBLOOM, ME
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06): : 979 - 999