Catheter flow sensor system and breathing measurements in rabbit

被引:0
|
作者
Matsuyama, Takuya [1 ]
Yamazaki, Yudai [1 ]
Shikano, Takaaki [2 ]
Shikida, Mitsuhiro [3 ]
Matsushima, Miyoko [4 ]
Kawabe, Tsutomu [4 ]
机构
[1] Nagoya Univ, Dept Micronano Syst Eng, Nagoya, Aichi 4648601, Japan
[2] Nagoya Univ, Dept Mech Engn, Nagoya, Aichi 4648601, Japan
[3] Nagoya Univ, Ctr Micro Nano Mechatron, Nagoya, Aichi 4648601, Japan
[4] Nagoya Univ, Dept Med Tech, Nagoya, Aichi 4648601, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A catheter flow sensor system is developed to directly measure the breathing characteristics in small bronchi. The flow sensor is fabricated on a 15-mu m thick biocompatible parylene HT film. The film is mounted inside the surface of a thermal shrinkable tube. Finally, a handling tube is connected to one end of the fabricated sensor. A guide tube and a fiberscope are used to insert the sensor into a rabbit bronchus. The fore-end position of the guide tube is confirmed from images taken by the fiberscope. The sensor directly evaluates the breathing characteristics of rabbits having and not having a pneumothorax. The per-cycle flow volume for a rabbit having a pneumothorax is found to be only 70-77% of that for a rabbit not having one.
引用
收藏
页码:616 / 619
页数:4
相关论文
共 50 条
  • [41] Sensor fusion by using a sliding observer for an underwater breathing system
    Carotenuto, Salvatore
    Iannelli, Luigi
    Manfredi, Sabato
    Santini, Stefania
    2005 44th IEEE Conference on Decision and Control & European Control Conference, Vols 1-8, 2005, : 7662 - 7667
  • [42] Breathing Detection with a Portable Impedance Measurement System: First Measurements
    Cordes, Axel
    Foussier, Jerome
    Leonhardt, Steffen
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 2767 - 2770
  • [43] Towards diagnostic flow measurement from a catheter tip pressure sensor
    Clark, Therese
    McCormick, Daniel
    Malpas, Simon
    Budgett, David
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 356 - 359
  • [44] Development of implantable catheter flow sensor into inside of bronchi for laboratory animal
    Shikida, Mitsuhiro
    Matsuyama, Takuya
    Yamada, Takayuki
    Matsushima, Miyoko
    Kawabe, Tsutomu
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (01): : 175 - 185
  • [45] Development of implantable catheter flow sensor into inside of bronchi for laboratory animal
    Mitsuhiro Shikida
    Takuya Matsuyama
    Takayuki Yamada
    Miyoko Matsushima
    Tsutomu Kawabe
    Microsystem Technologies, 2017, 23 : 175 - 185
  • [46] Implantable Catheter Flow Sensor with Legs in Air Passage for Laboratory Animal
    Yamada, Takayuki
    Ono, Ryota
    Matsuyama, Takuya
    Matsushima, Miyoko
    Kawabe, Tsutomu
    Shikida, Mitsuhiro
    2014 IEEE SENSORS, 2014,
  • [47] MEASUREMENTS OF CORONARY FLOW RESERVE WITH DOPPLER CATHETER FOR ASSESSING THE SUCCESSFUL PTCA
    WAINAI, Y
    HANDA, S
    IWANAGA, S
    KYOTANI, S
    SATO, T
    KUSUHARA, M
    IKEDA, F
    NISHIKAWA, Y
    IKEGAWA, T
    NOMA, S
    ABE, S
    HORI, S
    OHNISHI, S
    NAKAMURA, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (09): : 959 - 959
  • [48] SUCROSE SPACE MEASUREMENTS IN RABBIT CENTRAL NERVOUS SYSTEM
    FENSTERM.JD
    BARTLETT, MO
    FEDERATION PROCEEDINGS, 1967, 26 (02) : 763 - &
  • [49] SUCROSE SPACE MEASUREMENTS IN RABBIT CENTRAL NERVOUS SYSTEM
    FENSTERMACHER, JD
    BARTLETT, MO
    AMERICAN JOURNAL OF PHYSIOLOGY, 1967, 212 (06): : 1268 - +
  • [50] A SENSOR FOR FLOW MEASUREMENTS NEAR THE SURFACE OF A COMPRESSOR BLADE
    LIGRANI, PM
    GYLES, BR
    MATHIOUDAKIS, K
    BREUGELMANS, FAE
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (05): : 431 - 437