Catheter flow sensor system and breathing measurements in rabbit

被引:0
|
作者
Matsuyama, Takuya [1 ]
Yamazaki, Yudai [1 ]
Shikano, Takaaki [2 ]
Shikida, Mitsuhiro [3 ]
Matsushima, Miyoko [4 ]
Kawabe, Tsutomu [4 ]
机构
[1] Nagoya Univ, Dept Micronano Syst Eng, Nagoya, Aichi 4648601, Japan
[2] Nagoya Univ, Dept Mech Engn, Nagoya, Aichi 4648601, Japan
[3] Nagoya Univ, Ctr Micro Nano Mechatron, Nagoya, Aichi 4648601, Japan
[4] Nagoya Univ, Dept Med Tech, Nagoya, Aichi 4648601, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A catheter flow sensor system is developed to directly measure the breathing characteristics in small bronchi. The flow sensor is fabricated on a 15-mu m thick biocompatible parylene HT film. The film is mounted inside the surface of a thermal shrinkable tube. Finally, a handling tube is connected to one end of the fabricated sensor. A guide tube and a fiberscope are used to insert the sensor into a rabbit bronchus. The fore-end position of the guide tube is confirmed from images taken by the fiberscope. The sensor directly evaluates the breathing characteristics of rabbits having and not having a pneumothorax. The per-cycle flow volume for a rabbit having a pneumothorax is found to be only 70-77% of that for a rabbit not having one.
引用
收藏
页码:616 / 619
页数:4
相关论文
共 50 条
  • [21] Textile sensor for heat flow measurements
    Onofrei, Elena
    Codau, Teodor-Cezar
    Bedek, Gauthier
    Dupont, Daniel
    Cochrane, Cedric
    TEXTILE RESEARCH JOURNAL, 2017, 87 (02) : 165 - 174
  • [22] SENSOR FOR CATHETER-BASED MEASUREMENTS OF ELECTRICAL CONDUCTIVITY.
    Newbower, Ronald S.
    Trautman, Edwin D.
    IEEE Transactions on Biomedical Engineering, 1986, BME-33 (02) : 182 - 188
  • [23] SENSOR FOR CATHETER-BASED MEASUREMENTS OF ELECTRICAL-CONDUCTIVITY
    NEWBOWER, RS
    TRAUTMAN, ED
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 182 - 188
  • [24] ERRONEOUS PRESSURE MEASUREMENTS DUE TO CATHETER FLOW RESISTANCE
    REED, TD
    POLLACK, MM
    FIELDS, AI
    HOLBROOK, PR
    CRITICAL CARE MEDICINE, 1979, 7 (03) : 133 - 133
  • [25] Smart silicon system for a multi sensor catheter
    Yiannos, Manoli
    Eichholz, Jorg
    Kandler, Micheal
    Kordas, Norbert
    Langerbein, Anke
    Mokwa, Wilfried
    International Conference of Micro Electro, Opto, Mechanic Systems and Components, 1990,
  • [26] Development of a Catheter Propulsion System with Tactile Sensor
    Gao, Hongtao
    Hao, Yanling
    Du, Juan
    INFORMATION-AN INTERNATIONAL INTERDISCIPLINARY JOURNAL, 2010, 13 (06): : 2153 - 2162
  • [27] Implementing air flow sensor in a medical mask for breathing detection
    Rangel, Domingo
    Castillo, David Daniel Castelan
    HEALTH AND TECHNOLOGY, 2020, 10 (02) : 405 - 410
  • [28] Implementing air flow sensor in a medical mask for breathing detection
    Domingo Rangel
    David Daniel Castelán Castillo
    Health and Technology, 2020, 10 : 405 - 410
  • [29] Smart Catheter Flow Sensor for Continuous Regional Cerebral Blood Flow Monitoring
    Li, Chunyan
    Wu, Pei-Ming
    Wu, Zhizhen
    Ahn, Chong H.
    Hartings, Jed A.
    Narayan, Raj K.
    2011 IEEE SENSORS, 2011, : 1417 - 1420
  • [30] An electrochemical-sensor system for real-time flow measurements in porous materials
    Bathany, Cedric
    Han, Ja-Ryoung
    Abi-Samra, Kameel
    Takayama, Shuichi
    Cho, Yoon-Kyoung
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 115 - 121