Catheter flow sensor system and breathing measurements in rabbit

被引:0
|
作者
Matsuyama, Takuya [1 ]
Yamazaki, Yudai [1 ]
Shikano, Takaaki [2 ]
Shikida, Mitsuhiro [3 ]
Matsushima, Miyoko [4 ]
Kawabe, Tsutomu [4 ]
机构
[1] Nagoya Univ, Dept Micronano Syst Eng, Nagoya, Aichi 4648601, Japan
[2] Nagoya Univ, Dept Mech Engn, Nagoya, Aichi 4648601, Japan
[3] Nagoya Univ, Ctr Micro Nano Mechatron, Nagoya, Aichi 4648601, Japan
[4] Nagoya Univ, Dept Med Tech, Nagoya, Aichi 4648601, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A catheter flow sensor system is developed to directly measure the breathing characteristics in small bronchi. The flow sensor is fabricated on a 15-mu m thick biocompatible parylene HT film. The film is mounted inside the surface of a thermal shrinkable tube. Finally, a handling tube is connected to one end of the fabricated sensor. A guide tube and a fiberscope are used to insert the sensor into a rabbit bronchus. The fore-end position of the guide tube is confirmed from images taken by the fiberscope. The sensor directly evaluates the breathing characteristics of rabbits having and not having a pneumothorax. The per-cycle flow volume for a rabbit having a pneumothorax is found to be only 70-77% of that for a rabbit not having one.
引用
收藏
页码:616 / 619
页数:4
相关论文
共 50 条
  • [11] Wireless Stent Flow Sensor System for the Evaluation of Breathing Airflow in the Airway of Experimental Animals
    Hasegawa Y.
    Noma H.
    Matsushima M.
    Hasegawa S.
    Kawabe T.
    Shikida M.
    IEEJ Transactions on Sensors and Micromachines, 2022, 142 (01) : 2 - 7
  • [12] Characterization of basket-forceps-type micro-flow-sensor for breathing measurements in small airway
    Harada, Naoaki
    Hasegawa, Yoshihiro
    Ono, Ryota
    Matsushima, Miyoko
    Kawabe, Tsutomu
    Shikida, Mitsuhiro
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (12): : 5397 - 5406
  • [13] Characterization of basket-forceps-type micro-flow-sensor for breathing measurements in small airway
    Naoaki Harada
    Yoshihiro Hasegawa
    Ryota Ono
    Miyoko Matsushima
    Tsutomu Kawabe
    Mitsuhiro Shikida
    Microsystem Technologies, 2017, 23 : 5397 - 5406
  • [14] A Flexible Flow Sensor System and Its Characteristics for Fluid Mechanics Measurements
    Liu, Peng
    Zhu, Rong
    Que, Ruiyi
    SENSORS, 2009, 9 (12): : 9533 - 9543
  • [15] Measurements of hemodialysis catheter blood flow in vivo
    Twardowski, ZJ
    Haynie, JD
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (04): : 276 - 280
  • [16] Measurements of hemodialysis catheter blood flow in vivo
    Twardowski, Zbylut J.
    Haynie, J.D.
    1600, Wichtig Editore s.r.l. (25):
  • [17] THE EFFECT OF NASAL OXYGEN FLOW AND CATHETER POSITION ON THE ACCURACY OF END-TIDAL CARBON-DIOXIDE MEASUREMENTS BY A PHARYNGEAL CATHETER IN UNINTUBATED, SPONTANEOUSLY BREATHING SUBJECTS
    OBERG, B
    WALDAU, T
    LARSEN, VH
    ANAESTHESIA, 1995, 50 (08) : 695 - 698
  • [18] A FLEXIBLE SENSOR SYSTEM IN FOIL FOR COMBINED ABSOLUTE PRESSURE AND FLOW VELOCITY MEASUREMENTS
    Schwerter, Martin
    Gaeding, Marcel
    Leester-Schaedel, Monika
    Dietzel, Andreas
    2017 19TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2017, : 1104 - 1107
  • [19] Waterproof sensor system for simultaneous pressure and hot-film flow measurements
    Schwerter, Martin
    Leester-Schaedel, Monika
    Dietzel, Andreas
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 257 : 208 - 215
  • [20] Flow sensor keeps measurements in line
    Raymond, MK
    MACHINE DESIGN, 1997, 69 (14) : 48 - 48