Evaluating the effect of reduced entrance surface dose on neonatal chest imaging using subjective image quality evaluation

被引:12
|
作者
Conradie, Anita [1 ]
Herbst, Charles Petrus [1 ]
机构
[1] Univ Free State, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
来源
关键词
Neonatal; Chest X-rays; Dose; Rabbit phantom; Image quality; INTENSIVE-CARE-UNIT; RADIATION-EXPOSURE; RADIOGRAPHY; OPTIMIZATION; REDUCTION;
D O I
10.1016/j.ejmp.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: As hospitalized neonates are radiosensitive and often require numerous X-rays, institutions should investigate the optimal beam parameter combinations to deliver diagnostically acceptable quality images at the lowest possible entrance surface dose (ESD). Using a subjective approach, this study evaluated the effect of different beam parameter combinations on image quality. Methods and materials: Five rabbits simulated the neonatal chest. The ESD was reduced using a variation of voltage, tube current and filtration. Eight radiology registrars, blinded to the dose parameter information, ranked the digital X-ray images of three anatomical regions from best to worst using a variation of the multiple rank order method. T-tests compared the average values, obtained from the scores assigned by each observer to images acquired at different ESDs, for each region. The calculated intraclass correlation coefficient (ICC) assessed observer agreement. Results: Results showed that a 64% dose reduction was achievable by altering the beam parameters. Large variation among the observers was confirmed by an ICC value <0.5. A 95% confidence interval could not conclude that different ESD values, resulting in a 50-77% dose reduction compared to current practice, would result in different overall observed image quality. This was noted for all three regions indicating that no preference existed towards an image acquired with a specific beam parameter combination. Conclusions: The large variation in observers' opinion of acceptable image quality emphasizes the importance of subjective image quality evaluation in the clinical environment. The rabbit phantom and multiple rank order method are considered appropriate for these evaluations. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 50 条
  • [21] A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography
    Veldkamp, Wouter J. H.
    Kroft, Lucia J. M.
    van Delft, Jan Pieter A.
    Geleijns, Jacob
    JOURNAL OF DIGITAL IMAGING, 2009, 22 (02) : 114 - 125
  • [22] A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography
    Wouter J.H. Veldkamp
    Lucia J.M. Kroft
    Jan Pieter A. van Delft
    Jacob Geleijns
    Journal of Digital Imaging, 2009, 22 : 114 - 125
  • [23] Evaluation of image quality of a new CCD-based system for chest imaging
    Sund, P
    Båth, M
    Kheddache, S
    Tylén, U
    Månsson, LG
    MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE, 2000, 3981 : 251 - 258
  • [24] Depth-of-field effect in subjective and objective evaluation of image quality
    Zhang, Tingting
    Nefs, Harold
    Liu, Hantao
    Xia, Ling
    Liu, Xiaofeng
    Wu, Xiaoli
    PROCEEDINGS OF THE 2018 CONFERENCE ON RESEARCH IN ADAPTIVE AND CONVERGENT SYSTEMS (RACS 2018), 2018, : 308 - 312
  • [25] Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
    Hambali, Ahmad Shariff
    Ng, Kwan-Hoong
    Abdullah, Basri Johan Jeet
    Wang, Hwee-Beng
    Jamal, Noriah
    Spelic, David C.
    Suleiman, Orhan H.
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (01) : 25 - 34
  • [26] Image quality and dose evaluation in spiral chest CT examinations of patients with lung carcinoma
    Morán, LM
    Rodríguez, R
    Calzado, A
    Turrero, A
    Arenas, A
    Cuevas, A
    García-Castaño, B
    Gómez, N
    Morán, P
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922): : 839 - 846
  • [27] Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study
    Hasegawa H.
    Sato J.
    Kobayashi I.
    Radiological Physics and Technology, 2018, 11 (2) : 138 - 148
  • [28] Image Guidance On the TrueBeam STx: Evaluation of CBCT Imaging Dose and Quality
    Maxim, P. G.
    Fahimian, B. P.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S849 - S850
  • [29] Image Guidance on the TrueBeam STx: Evaluation of CBCT Imaging Dose and Quality
    Fahimian, B.
    Xing, L.
    Maxim, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Evaluation of compressed chest CT image quality using quantitative analysis
    Yamamoto, S
    Matsumoto, T
    Ueguchi, T
    Joukou, T
    Umeda, T
    Sasagaki, M
    Sukenobu, Y
    Honda, I
    Kawahara, M
    Cruz, M
    Hanayama, M
    Kusumi, Y
    Nakamura, H
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 892 - 892